PURPOSE: Intermolecular multiple quantum coherences (iMQCs) are a source of MR contrast with applications including temperature imaging, anisotropy mapping, and brown fat imaging. Because all applications are limited by signal-to-noise ratio (SNR), we developed a pulse sequence that detects intermolecular zero quantum coherences with improved SNR. METHODS: A previously developed pulse sequence that detects iMQCs, HOMOGENIZED with off resonance transfer (HOT), was modified with a multi-spin echo spatial encoding scheme (MSE-HOT). MSE-HOT uses a series of refocusing pulses to generate a stack of images that are averaged in postprocessing for higher SNR. MSE-HOT performance was quantified by measuring its temperature accuracy and precision during hyperthermia of ex vivo red bone marrow samples. RESULTS: MSE-HOT yielded a three-fold improvement in temperature precision relative to previous pulse sequences. Sources of improved precision were 1) echo averaging and 2) suppression of J-coupling in the methylene protons of fat. MSE-HOT measured temperature change with an accuracy of 0.6°C. CONCLUSION: MSE-HOT improved the temperature accuracy and precision of HOT to a level that is sufficient for hyperthermia of bone marrow.
n class="abstract_title">PURPOSE: Intermolecular multiple quantum coherences (iMQCs) are a source of MR contrast with applications including temperature imaging, anisotropy mapping, and brown fat imaging. Because all applications are limited by signal-to-noise ratio (SNR), we developed a pulse sequence that detects intermolecular zero quantum coherences with improved SNR. n>n class="abstract_title">METHODS: A previously developed pulse sequence that detects iMQCs, HOMOGENIZED with off resonance transfer (HOT), was modified with a multi-spin echo spatial encoding scheme (MSE-HOT). MSE-HOT uses a series of refocusing pulses to generate a stack of images that are averaged in postprocessing for higher SNR. MSE-HOT performance was quantified by measuring its temperature accuracy and precision during hyperthermia of ex vivo red bone marrow samples. RESULTS: MSE-HOT yielded a three-fold improvement in temperature precision relative to previous pulse sequences. Sources of improved precision were 1) echo averaging and 2) suppression of J-coupling in the methylene protons of fat. MSE-HOT measured temperature change with an accuracy of 0.6°C. CONCLUSION: MSE-HOT improved the temperature accuracy and precision of HOT to a level that is sufficient for hyperthermia of bone marrow.
Authors: Nicky H G M Peters; Lambertus W Bartels; Sara M Sprinkhuizen; Koen L Vincken; Chris J G Bakker Journal: J Magn Reson Imaging Date: 2009-03 Impact factor: 4.813