Literature DB >> 26077169

Comparison of two contemporary rotary systems in a pre-clinical student course setting.

M Marending1, P Biel1, T Attin1, M Zehnder1.   

Abstract

AIM: To assess two contemporary rotary instrumenting systems subjectively and objectively in a pre-clinical student course setting.
METHODOLOGY: Undergraduate dental students (n = 44) prepared mesiolingual canals of 3D-printed mandibular molar replicas (RepliDens, Zurich, Switzerland). The HyFlex and BioRace rotary systems, both previously unknown to the students, were used according to the manufacturers' guidelines after a short theoretical introduction. For comparison, a first-generation rotary system (ProFile .04), which the students knew from their previous education, was then used in a third RepliDens. Questionnaires were issued to note subjective experiences immediately after instrumentation. Objectively, time to instrument to size 40, .04 taper and shaping outcomes were analysed. Categorical data were compared using chi-square and Fisher's exact tests, numerical data according to goodness of fit to the normal distribution, P < 0.05.
RESULTS: Subjectively, the students liked the file size and sequence designation in the BioRace system significantly (P < 0.05) better than in the HyFlex counterpart, whilst they found better controllability with the HyFlex (P < 0.05), and reported no difference in cutting efficiency. They preferred both systems to the ProFile. Objectively, canal transportation was significantly less with the HyFlex (and the ProFile) systems compared to BioRace (P < 0.05). Both systems under investigation were statistically similar in terms of file fractures (nil), length control, and instrumentation time, which was considerably faster than with the ProFile control system.
CONCLUSIONS: HyFlex and BioRace had perceived and quantifiable strengths and weaknesses. Both systems were equally liked by the students and preferred over the ProFile first-generation rotary system.
© 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  3D-printed teeth; instrumenting system; simulated root canals; students

Mesh:

Year:  2015        PMID: 26077169     DOI: 10.1111/iej.12481

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  2 in total

1.  Distribution of sodium hypochlorite throughout the mesial root canal system of mandibular molars after adjunctive irrigant activation procedures: a micro-computed tomographic study.

Authors:  Juan Pacheco-Yanes; José C Provenzano; Marília F Marceliano-Alves; Isbelia Gazzaneo; Alejandro R Pérez; Lúcio S Gonçalves; José F Siqueira
Journal:  Clin Oral Investig       Date:  2019-06-26       Impact factor: 3.573

2.  Micro-computed tomographic evaluation of canal retreatments performed by undergraduate students using different techniques.

Authors:  Emmanuel João Nogueira Leal Silva; Felipe Gonçalves Belladonna; Marianna Fernandes Carapiá; Brenda Leite Muniz; Mariana Santoro Rocha; Edson Jorge Lima Moreira
Journal:  Restor Dent Endod       Date:  2018-01-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.