Literature DB >> 26074097

Trace analysis of total naphthenic acids in aqueous environmental matrices by liquid chromatography/mass spectrometry-quadrupole time of flight mass spectrometry direct injection.

Pamela Brunswick1, Dayue Shang2, Graham van Aggelen1, Ralph Hindle3, L Mark Hewitt4, Richard A Frank4, Maxine Haberl5, Marcus Kim6.   

Abstract

A rapid and sensitive liquid chromatography quadrupole time of flight method has been established for the determination of total naphthenic acid concentrations in aqueous samples. This is the first methodology that has been adopted for routine, high resolution, high throughput analysis of total naphthenic acids at trace levels in unprocessed samples. A calibration range from 0.02 to 1.0μgmL(-1) total Merichem naphthenic acids was validated and demonstrated excellent accuracy (97-111% recovery) and precision (1.9% RSD at 0.02μgmL(-1)). Quantitative validation was also demonstrated in a non-commercial oil sands process water (OSPW) acid extractable organics (AEOs) fraction containing a higher percentage of polycarboxylic acid isomers than the Merichem technical mix. The chromatographic method showed good calibration linearity of ≥0.999 RSQ to 0.005μgmL(-1) total naphthenic acids with a precision <3.1% RSD and a calculated detection limit of 0.0004μgmL(-1) employing Merichem technical mix reference material. The method is well suited to monitoring naturally occurring and industrially derived naphthenic acids (and other AEOs) present in surface and ground waters in the vicinity of mining developments. The advantage of the current method is its direct application to unprocessed environmental samples and to examine natural naphthenic acid isomer profiles. It is noted that where the isomer profile of samples differs from that of the reference material, results should be considered semi-quantitative due to the lack of matching isomer content. The fingerprint profile of naphthenic acids is known to be transitory during aging and the present method has the ability to adapt to monitoring of these changes in naphthenic acid content. The method's total ion scan approach allows for data previously collected to be examined retrospectively for specific analyte mass ions of interest. A list of potential naphthenic acid isomers that decrease in response with aging is proposed and a quantitative assay of an adamantane carboxylic acid is reported. Crown
Copyright © 2015. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Environmental; Isomers; Merichem; Naphthenic; OSPW; QToF

Mesh:

Substances:

Year:  2015        PMID: 26074097     DOI: 10.1016/j.chroma.2015.05.048

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Non-target profiling of bitumen-influenced waters for the identification of tracers unique to oil sands processed-affected water (OSPW) in the Athabasca watershed of Alberta, Canada.

Authors:  Craig B Milestone; Chenxing Sun; Jonathan W Martin; Greg Bickerton; James W Roy; Richard A Frank; L Mark Hewitt
Journal:  Rapid Commun Mass Spectrom       Date:  2021-02-15       Impact factor: 2.586

2.  Development of a Reduced-Volume Acute Lethality Toxicity Test for Hyalella azteca.

Authors:  Maegan R Rodrigues; Richard A Frank; Daniel M Schissler; Lorna E Deeth; Lisa R Brown; Amanda M Hedges; D George Dixon; L Mark Hewitt; Adrienne J Bartlett
Journal:  Environ Toxicol Chem       Date:  2020-09-16       Impact factor: 3.742

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.