Literature DB >> 26072366

Inverted distal clavicle anatomic locking plate for displaced medial clavicle fracture.

Yong Wang1, Jiannong Jiang, Bin Dou, Panjun Zhang.   

Abstract

Fractures of the medial clavicle are rare injuries. Recently, open reduction and internal fixation has been recommended for displaced medial clavicle fractures in order to prevent non-union and dysfunction. Because of the rarity of this injury, the optimal fixation device has not yet been established. In this report, we describe a case of a 40-year-old male patient who sustained a significantly displaced medial clavicle fracture treated by open reduction and internal fixation using an inverted distal clavicle anatomic locking plate. At the 12 months follow-up, the patient recovered well, had returned to pre-injury job, and was quite satisfied with the outcome. Internal fixation of medial clavicle fracture using an inverted distal clavicle anatomic locking plate of the ipsilateral side appears to be a good treatment option.

Entities:  

Mesh:

Year:  2015        PMID: 26072366     DOI: 10.1007/s00402-015-2259-x

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  6 in total

1.  Displaced medial clavicle fractures: operative treatment with locking compression plate fixation.

Authors:  Herman Frima; Roderick M Houwert; Christoph Sommer
Journal:  Eur J Trauma Emerg Surg       Date:  2018-10-11       Impact factor: 3.693

2.  [Effectiveness analysis of distal radius microplate locking plate for treatment of displaced fracture of medial clavicle].

Authors:  Jinyuan Zeng; Junjian Ye; Yun Xie; Chunyong Chen; Zhangxiong Lin
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-05-15

Review 3.  An evaluation of treatment options for medial, midshaft, and distal clavicle fractures: a systematic review and meta-analysis.

Authors:  Christopher Vannabouathong; Justin Chiu; Rahil Patel; Shreyas Sreeraman; Elias Mohamed; Mohit Bhandari; Kenneth Koval; Michael D McKee
Journal:  JSES Int       Date:  2020-05-04

4.  Medial clavicle pseudarthrosis successfully treated with an inverted distal clavicle locking plate.

Authors:  Yu Sasaki; Sang Yang Lee; Takashi Iwakura; Tomoaki Fukui; Keisuke Oe; Tomoyuki Matsumoto; Takehiko Matsushita; Teruya Kawamoto; Yutaka Mifune; Ryosuke Kuroda; Takahiro Niikura
Journal:  Ann Med Surg (Lond)       Date:  2019-06-06

5.  Displaced Medial-End Clavicle Fractures Treated with Locking Plate Osteosynthesis.

Authors:  Zhongyu Liu; Jinli Zhang; Xu Tian; Shilian Kan
Journal:  Med Sci Monit       Date:  2019-10-09

6.  A Sternoclavicular Joint-Specific Plate for the Displaced Medial-End Clavicle Fracture.

Authors:  Yunli Zhu; Fucun Liu; Lie Lin; Chuanyi Zhang; Bin Wang; Shouli Wang
Journal:  Front Surg       Date:  2022-04-29
  6 in total