Literature DB >> 26071496

Effects of gadolinium-based contrast agent concentrations (0.5 M or 1.0 M) on the diagnostic performance of magnetic resonance imaging examinations: systematic review of the literature.

Eric Lancelot1, John Froehlich2, Oliver Heine3, Pierre Desché1.   

Abstract

Background To date there is no agreement as to what is the optimal concentration for gadolinium-based contrast agents (GBCAs). Purpose To assess whether diagnostic performance differences exist between 0.5 M and 1.0 M GBCAs used for magnetic resonance imaging (MRI). Material and Methods A PubMed literature search identified 21 clinical studies published between 2005 and 2013 which evaluated the diagnostic efficacy of both types of GBCAs. Study design, type of procedure, GBCA administration mode, imaging performances, impact on patient management, study limitations, and biases were analyzed. No statistical test was performed on pooled data. Results Sixteen comparative and five non-comparative studies were analyzed, involving 2183 patients who underwent MRI procedures for various indications. In 67% of the studies, 0.5 M and 1.0 M GBCAs were injected at equimolar gadolinium amounts per kg body weight. Only 33% applied the same molar flow rate for delivery of the GBCAs. No significant differences between GBCAs were reported for 23 out of 27 qualitative endpoints (mainly image quality, lesion, and vessel visualization) and 29 out of 40 quantitative endpoints. Three out of four studies with non-equimolar delivery rates showed better contrast-to-noise and signal-to-noise ratios for 1.0 M gadobutrol, without showing an impact on diagnostic performance. Methodological biases were identified in several studies impairing the interpretation of comparisons. Conclusion Imaging differences between 0.5 M and 1.0 M GBCAs were essentially observed under non-equimolar delivery rates. However, they did not result into greater diagnostic efficacy when performed under equimolar conditions.

Entities:  

Keywords:  Magnetic resonance imaging (MRI); comparative studies; contrast agents – intravenous; efficacy studies

Mesh:

Substances:

Year:  2016        PMID: 26071496     DOI: 10.1177/0284185115590434

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  2 in total

1.  Dynamic contrast-enhanced MR imaging of the prostate: intraindividual comparison of gadoterate meglumine and gadobutrol.

Authors:  Chau Hung Lee; Balamurugan Vellayappan; Matthias Taupitz; Bernd Hamm; Patrick Asbach
Journal:  Eur Radiol       Date:  2019-07-01       Impact factor: 5.315

2.  The Effect of Deep Learning-Based QSM Magnetic Resonance Imaging on the Subthalamic Nucleus.

Authors:  Yuanqin Liu; Qinglu Zhang; Lingchong Liu; Cuiling Li; Rongwei Zhang; Guangcun Liu
Journal:  J Healthc Eng       Date:  2021-09-15       Impact factor: 2.682

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.