Di Zhang1, He Zhao1, Zhuangjun Fan2, Mingjie Li1, Penghui Du1, Chenming Liu1, Yuping Li1, Haitao Li3, Hongbin Cao1.
Abstract
A sensitive and noble amperometric horseradish peroxidase (HRP) biosensor is fabricated via the deposition of gold nanoparticles (Entities:
Mesh:
Substances:
Year: 2015 PMID: 26069960 PMCID: PMC4466542 DOI: 10.1371/journal.pone.0130156
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Schematic illustration of the mechanism underlying the detection of H2O2 using HRP-AuNPs-CESM-GCE electrochemical biosensor.
Fig 2Representative SEM images and EDS elemental analysis of modified electrode.
SEM images of CESM-GCE (A) and AuNPs-CESM-GCE (B), (C). EDS elemental analysis (D) and scanning images (E) of AuNPs-CESM-GCE; EDS element scanning image with all elements (a) and elemental distribution of C (b), Cl (c), Au (d) and O (e).
Fig 3X-ray diffraction patterns (A), FTIR spectra (B) and XPS spectra (C) of modified electrodes.
XPS spectra of wide-scan survey (a), XPS C1s spectra of ESM (b), CESM (c), GCE (d) and CESM-GCE (e).
Elemental composition determined from the wide-scan survey XPS spectra, and sp2/(sp2+sp3) of C1s spectra for ESM, CESM, GCE, and CESM-GCE.
| ESM | CESM | GCE | CESM-GCE | |
|---|---|---|---|---|
|
| 68.2 | 82.68 | 89.93 | 80.44 |
|
| 13.54 | 5.82 | 1.08 | 0.32 |
|
| 18.26 | 11.5 | 8.99 | 19.24 |
|
| 0.59 | 0.71 | 0.55 | 0.81 |
Fig 4Cyclic voltammograms of modified electrodes.
Bare GCE (a), CESM-GCE (b), AuNPs–CESM-GCE (c), in 0.1 M pH 7.0 PBS at a scan rate of 50 mV/s.
Fig 5Electrochemical impedance spectroscopy of modified electrodes.
Bare GCE (a), CESM-GCE (b), AuNPs–CESM-GCE (c), in 0.1 M pH 7.0 PBS containing 1 mM [Fe(CN)6]3-/4- (inset: Randle’s equivalent circuit).
EIS data of different modified electrodes in 1 mM [Fe(CN)6]3-/4-.
| Electrode | Rs(Ω) | CPE(F) | n | Rct(Ω) | W(Ω) |
|---|---|---|---|---|---|
|
| 2.77 | 3.71E-05 | 0.824 | 148.9 | 0.0094 |
|
| 4.17 | 5.17E-03 | 0.317 | 35.48 | 0.0004 |
|
| 2.33 | 3.33E-03 | 0.484 | 11.38 | 0.0072 |
Fig 6Typical amperometric responses of the different modified electrodes.
The applied potential was -0.2 V vs. SCE in 0.1 M PBS solution (pH = 7.0).
Fig 7Cyclic voltammograms (A) and amperometric responses (B) of HRP-AuNPs-CESM-GCE electrode with successive addition of H2O2.
(A) 200 μM H2O2 was added continuously at a scan rate of 50 mV/s (inset: corresponding calibration plot of peak current against different concentrations of H2O2). (B) Amperometric responses of HRP-AuNPs–CESM-GCE electrode during successive addition of aliquots of H2O2 (inset: corresponding calibration plot of steady-state currents as a function of different concentrations of H2O2) at the applied potential of -0.2 V vs. SCE in 0.1 M PBS solution (pH = 7.0).