Literature DB >> 26069410

Physical-mechanical properties of Bis-EMA based root canal sealer with different fillers addition.

Marcela Oliveira de Souza1, Vicente Castelo Branco Leitune1, Priscila Veit Bohn1, Susana Maria Werner Samuel1, Fabrício Mezzomo Collares1.   

Abstract

AIM: To evaluate influence of three different filler particles on an experimental Bisphenol A ethoxylated dimethacrylate (Bis-EMA) based root filling material.
MATERIALS AND METHODS: Resin-based endodontic sealers were produced using Bis-EMA, camphorquinone, ethyl 4-dimethylaminobenzoate (EDAB), N, N-dihydroxyethyl-p-toluidine (DHEPT), butylated hydroxytoluene (BHT), and benzoyl peroxide. The experimental groups were formulated adding 10, 20, 30, 40, and 50% of calcium tungstate (CaWO4), ytterbium trifluoride(YbF3), and tantalum oxide(Ta2O5). Flow, thickness, and radiopacity tests were conducted in accordance with ISO 6876. Sorption and solubility (SL) tests were conducted in accordance with ISO 4049, pH was measured with a pH meter, and degree of conversion (DC) was evaluated with Fourier transform infrared spectroscopy (FTIR). For radiopacity, two-way analysis of variance (ANOVA) and Tukey's multiple comparison test was performed. For DC analysis, one-way ANOVA and Tukey's multiple comparison test was performed. All statistical analyses were performed with a significance level of 5%.
RESULTS: All groups showed lower flow with increased filler concentration. All groups showed film thickness values lower than 50μm, as ISO recommends, except CaWO450% group (76.7μm). pH values varied from 5.95 (± 0.07) in YbF340% group to 6.90 (± 0.07) in Ta2O540% group. In the radiopacity test, YbF330%, Ta2O540%, and Ta2O550% groups showed no statistical significant difference to 3mmAl. Ta2O5 and YbF3 groups in 10, 20, and 30% concentrations presented sorption and SL values as ISOrecommendation. Addition ofTa2O5 and CaWO4 decreased DC after 14 days. YbF3 addition showed no difference in DC from control group.
CONCLUSION: YbF3 filler addition promoted higher properties compared to CaWO4 and Ta2O5 on Bis-EMA based root canal sealer.

Entities:  

Keywords:  Ethoxylated bisphenol-A-dimethacrylate; root canals sealer; ytterbium trifluoride

Year:  2015        PMID: 26069410      PMCID: PMC4450530          DOI: 10.4103/0972-0707.157259

Source DB:  PubMed          Journal:  J Conserv Dent        ISSN: 0972-0707


INTRODUCTION

The filling material choice is of paramount importance to longevity of endodontic treatment, complementing the canal preparation.[1] Methacrylate-based materials are a reliable matrix for filler incorporation and recently have been used for root canal sealers.[23] Dimethacrylates like bisphenol Aethoxylated (Bis-EMA) appears to be a further trend in formulation of methacrylate-based dental materials, with a stiff phenyl ring core; however without the two pendant hydroxyl groups which are responsible for the water affinity and high viscosity like Bis-GMA based methacrylate matrix.[45] The aim of this study to evaluate influence of three different filler particles on an experimental Bis-EMA based root filling materials.

MATERIALS AND METHODS

Formulation

Experimental dual cured sealers were obtained from a base resin of Bisphenol A ethoxylated dimethacrylate (Bis-EMA). Camphorquinone, ethyl 4-dimethylaminobenzoate (EDAB), N, N-dihydroxyethyl-p-toluidine (DHEPT), and benzoyl peroxide (Esstech Inc, Essington, Pennsylvania, USA) were used for polymerization system. Butylated hydroxytoluene (BHT) was used to inhibit autopolymerization in 0.01 wt%. Calcium tungstate (CaWO4), ytterbium trifluoride (YbF3), and tantalum oxide (Ta2O5) at 10, 20, 30, 40, and 50% in weight, were added as filler to the base resin. The particle size distribution was assessed using a laser diffraction particle size analyzer (CILAS 1180, Orleans, France). The mean size of filler particles used was 17.79, 14.37, and 6.26 μm, respectively. Fifteen endodontic experimental resin paste/paste sealers with different concentrations and one with no filler addition were developed. To perform sealer photoactivation, a light-emitting diode activation unit (Radii Cal, SDI, Bayswater, Victoria, Australia) with irradiation value of 1, 200 mW/cm2 was used for all tests.

Flow

The flow test was conducted according to ISO 6876:2001. A total of 0.05 (± 0.005) mL of each experimental sealer was placed on a glass plate (40 40 5 mm). At 180 ± 5s after mixing was started, another plate with a mass of 20 ± 2 g and a load of 100g was placed on top of the material. Ten minutes after mixing had been started, the load was removed, and the major and minor diameters of the compressed material were measured using a digital caliper. If both measurements were within 1 mm of each other, the test was conducted three times for each group (n = 3), and the mean value was recorded.

Film Thickness

The film thickness was evaluated according to ISO 6876:2001. Two glass plates that measured 5 mm in thickness and 40 mm in length were placed together, and their combined thickness was measured. The center of one of the plates was covered with 0.05 (± 0.005) mL of experimental sealer, and a second plate was placed on top of the material. At 180 ± 5 s after the start of mixing, a load of 150 N was applied on top of the glass plate. Ten minutes after the start of mixing, the thickness of the two glass plates and the interposed sealer film was measured. The mean value of three measurements for each sealer was recorded as the film thickness of the material.

Water Sorption (WS) and Solubility (SL)

The sorption and SL tests were based on ISO 4049:2009, with the exception of the dimensions of the samples. Five samples with 6.0 mm (± 0.5 mm) diameter and 1.0 mm (± 0.2 mm) of thickness for each group (n = 5) were made using a Teflon matrix. The amounts of WS and SL for each sample were calculated.[6]

pH

The pH determination was realized with a digital pH meter (PH21, Hanna Instruments, São Paulo, SP, Brazil). The solution employed to measure the pH was the resulting water from the sorption and SL test where each sample was stored for 7 days at 37°C. The electrode was immersed 4 cm into the solution and a temperature probe was used so that the pH was automatically compensated with temperature variations.

Radiopacity

Radiographic images were obtained by a digital system with phosphorous plates (VistaScan, Dürr Dental GmbH & Co. KG, Bietigheim-Bissingen, Germany), the specimens were 6.0 mm (± 0.5 mm) in diameter and 1.0 mm (± 0.2 mm) in thickness (n = 5). The X-ray source (DabiAtlante model Spectro 70×) was operated with a tungsten anode at 70 kV and 8 mA, exposure time of 0.4s and a focus-film distance of 400 mm. For each film, one specimen from each group with the same concentration was used, resulting in five films per concentration. For all images, an aluminium step-wedge was exposed simultaneously with the specimens. The thickness of the aluminium step-wedge ranged from 0.5 to 9.0 mm. The images were analyzed using Photoshop software (Adobe Systems Incorporated, San Jose, CA, USA). The means and standard deviations of the grey levels (pixel density) of the aluminium step-wedge and the specimens were measured in a standardized area of 2.0 mm2.[7]

Degree of Conversion (DC)

The DC of the sealers was evaluated using Fourier transform infrared spectroscopy (FTIR) with a Vetrex 70 (Bruker Optics, Ettlingen, Germany), equipped with an attenuated total reflectance device composed of a horizontal diamond crystal with a mirror angle of 45 degrees. A support was coupled to fix the light-curing unit and standardize the distance between the fiber tip and sample at 5 mm. Opus software (Bruker Optics, Ettlingen, Germany) was used with Blackman-Harris 3-Term apodization in a range of 4,000-400 cm−1 and resolution of 4 cm−1. With this setup, one spectrum was obtained prior to photocuring and one immediately after photocuring. The samples (3 μl) were directly dispensed onto the diamond crystal and light-activated for 120s (polymer immediate) and after 14 days storage at 37°C (polymer at 14 days). The test was repeated three times on each group (n = 3).

Statistical Analysis

Flow, thickness, and radiopacity tests were conducted in accordance with ISO 6876. Sorption and SL tests were conducted in accordance with ISO 4049, pH was measured with a pHmeter and DC was evaluated with FTIR. For radiopacity, two-way analysis of variance (ANOVA) and Tukey's multiple comparison test was performed. For DC analysis, one-way ANOVA and Tukey's multiple comparison test. All statistical analyses were performed with a significance level of 5%.

RESULTS

Table 1 shows flow, film thickness, and pH results. Flow of experimental sealers ranged from 10 ± 0.1 to 30 ± 0.2 mm. As the filler concentration increased, the flow decreased for all groups (P < 0.05). The groups with addition of Ta2O5 showed higher flow compared to groups with YbF3 and CaWO4 (P < 0.05). Film thickness ranged from 10 to 76 μm. The groups showed a film thickness up to 50 μm, except for the group CaWO450% (76.7 μm). The pH of experimental sealers ranged from 5.95 ± 0.07 (YbF340%) to 6.90 ± 0.07 (Ta2O540%) (P < 0.05).
Table 1

Means and standard deviation for the flow, film thickness, pH, sorption, and solubility of experimental sealers

Means and standard deviation for the flow, film thickness, pH, sorption, and solubility of experimental sealers The groups with CaWO4 addition showed the highest values of WS and SL. The groups with YbF3 and Ta2O5 addition at 10, 20, and 30% showed values of WS and SL in accordance with ISO 4049 standards [Table 1]. The results of radiopacity are shown in Figure 1. The groups Ta2O540 and 50% and YbF330% showed no statistically significant difference to 3 mm Al, as recommended by ISO 6876 for root canal sealer. The DC of experimental sealers is shown in Figure 2. The groups with addition of Ta2O5 and CaWO4 presented lower values of DC than the control and YbF3 groups (P < 0.05).
Figure 1

Means and standard deviations of radiopacity values, in pixels, of experimental sealers. Columns marked with *represent no significant differences to 2-mmAl. Columns marked with # represent no significant differences to 3-mmAl. P > 0.05

Figure 2

Means and standard deviations of degree of conversion after 14 days of experimental sealers. Bars connected by the line showed no significant difference to control group. P > 0.05

Means and standard deviations of radiopacity values, in pixels, of experimental sealers. Columns marked with *represent no significant differences to 2-mmAl. Columns marked with # represent no significant differences to 3-mmAl. P > 0.05 Means and standard deviations of degree of conversion after 14 days of experimental sealers. Bars connected by the line showed no significant difference to control group. P > 0.05

DISCUSSION

Root canal sealers with increased physical-mechanical properties are related to high quality root filling.[8] This study evaluated experimental root canal sealers with Bis-EMA as resinous matrix and showed reliable properties for root filling. The incorporation of inorganic fillers is used to increased related properties of materials, such as radiopacity and viscosity. The presence of fillers allow the root canal sealers to be identified in radiographic images and increase the accuracy of diagnostics.[79] Groups with 40 and 50% of Ta2O5 and 30% of YbF3 presented values in accordance toISO6876for root canal sealers. On the other hand, groups with CaWO4 obtained lower values than 3 mm aluminum even at high concentrations. The low radiopacity of CaWO4 is one reason to this filler be used as adjuvant in commercial sealers. As the concentration of fillers increased, the viscosity of root canal sealers increased, decreasing the flow.[10] Groups with Ta2O5 at 10, 20, and 30%;YbF3 at 10%; and CaWO4 at 10% were in accordance of the flow requirements of ISO. Despite ISO recommendations of flow; higher than 20 mm, groups presenting values higher than clinical demanded, since the root canal sealers used in the present study are resin-based material.[11] ISO 6876 standardization describes requirements for water-based sealers. All groups presented film thickness lower than 50 μm as recommended by ISO 6876, except for group with CaWO4. The determinant influence to radiopacity, flow, and film thickness was carried by inorganic fillers, and Bis-EMA acted as resin matrix that allowed the incorporation of high amount of particles. Resin-based root canal materials present a radical polymerization and low DC. Formed polymeris more prone to degradation leading to leached compounds that could achieve periapical region. The presence of uncured material in the apex could promote tissue inflammatory reaction and could lead to clinical failure of endodontic treatment. In the present study, the groups with addition ofYbF3 showed a higher DC compared to the groups with CaWO4 and Ta2O5. The DC of photo activated resinous materials increases with the level of radiated energy.[12] The initial generation of free radicals of methacrylate monomers is directly related to the radiation absorbed by the material, such as photo activated sealers. The DC is proportional to the square root of the light intensity absorbed by photo initiator system and the concentration of photo initiator.[13] Therefore, amore opaque material promotes a physical barrier to light transmission, generating lower DC of sealer. In a visual analysis of formulated sealers, cements with YbF3 were more translucent than cements with CaWO4 and Ta2O5. The YbF3 has refractive index (1.51) similar to the matrix resin used (1.7), which could not interfere significantly with the absorption of light. Refractive index value of filler should be ideally closer to resin matrix, producing an homogeneous material, benefiting the curing process. Considering that a high pH could alter tissue inflammatory conditions in the apical region resulting in a bactericidal effect and a faster repair process, the alkalinity of the sealer is important.[14] The pHo fall experimental groups ranged from 5.95 to 6.9 favoring biocompatibility. WS and SL are related to degradation of materials.[1516] The infiltration of water into the resin matrix may cause plasticization of the formed polymer network, leading to the polymer degradation.[615] The groups with YbF3 and Ta2O5 addition at 10, 20, and 30% showed values of WS and SL in accordance with ISO 4049 standards. CaWO4 addition groups in all concentrations showed higher WS values, which could increase degradation and decrease mechanical properties.[1718] High SL of asealer must be avoided in order to prevent release of monomers that could lead to tissue cytotoxicity.[1920] Furthermore, dissolution of sealer could lead to gaps between the filling material and theroot canal walls.[2021] The properties of endodontic sealers are mainly determined by the type and proportions of the main components. In this study, Bis-EMA enabled the addition of filler particles maintaining acceptable properties of sealers.

CONCLUSION

YbF3 filler addition promoted higher properties compared to CaWO4 and Ta2O5 on Bis-EMA based root canal sealer.
  19 in total

1.  Solubility of root-canal sealers in water and artificial saliva.

Authors:  E Schäfer; T Zandbiglari
Journal:  Int Endod J       Date:  2003-10       Impact factor: 5.264

2.  The influence of hygroscopic expansion of resin-based restorative materials on artificial gap reduction.

Authors:  Cui Huang; Lee-hoi Kei; Stephen H Y Wei; Gary S P Cheung; Franklin R Tay; David H Pashley
Journal:  J Adhes Dent       Date:  2002       Impact factor: 2.359

3.  Variability of physicochemical properties of an epoxy resin sealer taken from different parts of the same tube.

Authors:  J V Baldi; R A Bernardes; M A H Duarte; R Ordinola-Zapata; B C Cavenago; J C S Moraes; I G de Moraes
Journal:  Int Endod J       Date:  2012-04-09       Impact factor: 5.264

4.  Physicochemical properties of methacrylate resin-based root canal sealers.

Authors:  Gabriela Alessandra Marin-Bauza; Fuad Jacob Abi Rached-Junior; Aline Evangelista Souza-Gabriel; Manoel Damião Sousa-Neto; Carlos Eduardo Saraiva Miranda; Yara Teresinha Correa Silva-Sousa
Journal:  J Endod       Date:  2010-07-04       Impact factor: 4.171

Review 5.  Hygroscopic and hydrolytic effects in dental polymer networks.

Authors:  Jack L Ferracane
Journal:  Dent Mater       Date:  2005-08-08       Impact factor: 5.304

6.  Coronal sealing ability of a new root canal filling material.

Authors:  Emre Bodrumlu; Umut Tunga
Journal:  J Can Dent Assoc       Date:  2007-09       Impact factor: 1.316

7.  Disintegration of endodontic cements in water.

Authors:  A E Kaplan; F Goldberg; L P Artaza; A de Silvio; R L Macchi
Journal:  J Endod       Date:  1997-07       Impact factor: 4.171

8.  Odontoblast-like cytodifferentiation of human dental pulp cells in vitro in the presence of a calcium hydroxide-containing cement.

Authors:  D Seux; M L Couble; D J Hartmann; J P Gauthier; H Magloire
Journal:  Arch Oral Biol       Date:  1991       Impact factor: 2.633

9.  Influence of 2-hydroxyethyl methacrylate concentration on polymer network of adhesive resin.

Authors:  Fabrício Mezzomo Collares; Fabrício Aulo Ogliari; César Henrique Zanchi; Cesar Liberato Petzhold; Evandro Piva; Susana Maria Werner Samuel
Journal:  J Adhes Dent       Date:  2011-04       Impact factor: 2.359

10.  Niobium pentoxide as a new filler for methacrylate-based root canal sealers.

Authors:  V C B Leitune; A Takimi; F M Collares; P D Santos; C Provenzi; C P Bergmann; S M W Samuel
Journal:  Int Endod J       Date:  2012-08-11       Impact factor: 5.264

View more
  1 in total

1.  Exploring Needle-Like Zinc Oxide Nanostructures for Improving Dental Resin Sealers: Design and Evaluation of Antibacterial, Physical and Chemical Properties.

Authors:  Fabrício M Collares; Isadora M Garcia; Mariana Klein; Clarissa F Parolo; Felipe Antonio L Sánchez; Antônio Takimi; Carlos P Bergmann; Susana Maria W Samuel; Mary Anne Melo; Vicente Cb Leitune
Journal:  Polymers (Basel)       Date:  2020-04-02       Impact factor: 4.329

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.