Literature DB >> 26067039

2-D arterial wall motion imaging using ultrafast ultrasound and transverse oscillations.

Sebastien Salles, Adrian J Y Chee, Damien Garcia, Alfred C H Yu, Didier Vray, Herve Liebgott.   

Abstract

Ultrafast ultrasound is a promising imaging modality that enabled, inter alia, the development of pulse wave imaging and the local velocity estimation of the so-called pulse wave for a quantitative evaluation of arterial stiffness. However, this technique only focuses on the propagation of the axial displacement of the artery wall, and most techniques are not specific to the intima-media complex and do not take into account the longitudinal motion of this complex. Within this perspective, this paper presents a study of two-dimensional tissue motion estimation in ultrafast imaging combining transverse oscillations, which can improve motion estimation in the transverse direction, i.e., perpendicular to the beam axis, and a phase-based motion estimation. First, the method was validated in simulation. Two-dimensional motion, inspired from a real data set acquired on a human carotid artery, was applied to a numerical phantom to produce a simulation data set. The estimated motion showed axial and lateral mean errors of 4.2 ± 3.4 μm and 9.9 ± 7.9 μm, respectively. Afterward, experimental results were obtained on three artery phantoms with different wall stiffnesses. In this study, the vessel phantoms did not contain a pure longitudinal displacement. The longitudinal displacements were induced by the axial force produced by the wall's axial dilatation. This paper shows that the approach presented is able to perform 2-D tissue motion estimation very accurately even if the displacement values are very small and even in the lateral direction, making it possible to estimate the pulse wave velocity in both the axial and longitudinal directions. This demonstrates the method's potential to estimate the velocity of purely longitudinal waves propagating in the longitudinal direction. Finally, the stiffnesses of the three vessel phantom walls investigated were estimated with an average relative error of 2.2%.

Entities:  

Mesh:

Year:  2015        PMID: 26067039     DOI: 10.1109/TUFFC.2014.006910

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Evaluation of the Transverse Oscillation Technique for Cardiac Phased Array Imaging: A Theoretical Study.

Authors:  Brecht Heyde; Nick Bottenus; Jan D'hooge; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-10-28       Impact factor: 2.725

2.  3-D Intravascular Characterization of Blood Flow Velocity Fields with a Forward-Viewing 2-D Array.

Authors:  Brooks D Lindsey; Bowen Jing; Saeyoung Kim; Graham C Collins; Muralidhar Padala
Journal:  Ultrasound Med Biol       Date:  2020-06-30       Impact factor: 2.998

3.  Sidelobe reduction for plane wave compounding with a limited frame number.

Authors:  Wei Guo; Yuanyuan Wang; Guoqing Wu; Jinhua Yu
Journal:  Biomed Eng Online       Date:  2018-07-13       Impact factor: 2.819

4.  In vitro performance of echoPIV for assessment of laminar flow profiles in a carotid artery stent.

Authors:  Astrid M Hoving; Jason Voorneveld; Julia Mikhal; Johan G Bosch; Erik Groot Jebbink; Cornelis H Slump
Journal:  J Med Imaging (Bellingham)       Date:  2021-01-13

5.  Characterization of Vortex Flow in a Mouse Model of Ventricular Dyssynchrony by Plane-Wave Ultrasound Using Hexplex Processing.

Authors:  Akshay Shekhar; Orlando Aristizabal; Glenn I Fishman; Colin K L Phoon; Jeffrey A Ketterling
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.