| Literature DB >> 26066532 |
Sarah J Johnson1, F Rohan Walker2.
Abstract
Binary image thresholding is the most commonly used technique to quantitatively examine changes in immunolabelled material. In this article we demonstrate that if implicit assumptions predicating this technique are not met then the resulting analysis and data interpretation can be incorrect. We then propose a transparent approach to image quantification that is straightforward to execute using currently available software and therefore can be readily and cost-effectively implemented.Entities:
Mesh:
Year: 2015 PMID: 26066532 PMCID: PMC4464180 DOI: 10.1038/srep10607
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1(A) Illustrates the standard thresholding procedure on a 20× image of Iba-1 labelled microglial cells from the lateral hypothalamus of the rat passed through a standard thresholding routine using the threshold function within Fiji. Upper right: using a relatively conservative inclusion criteria (included material is shown in red) substantial portions of the branching structure of the cell are omitted (as indicated by blue arrow heads). Lower left: increasing the level of threshold inclusiveness results in substantially more of the cell processes being included but some evidence of background inclusion (otherwise known as ‘flaring’) can be observed (black arrows). Lower right: increasing the threshold further results in complete coverage of the original cell by the threshold but results in substantial levels of flaring. (B–D) Examines the process of deploying conventional thresholding on a set of images from an actual experiment looking at whether or not an experimental intervention has modified the expression of a protein known as glial fibrillary acid protein (GFAP) within astrocyte cells in the hippocampus (n = 8/group). (B) Illustrates the thresholding procedure on a 20× image from a control showing the respective material included if the threshold cut-point was set at a pixel intensity of 55, 70, 85, 100 and 115 (out of 256 possible intensities). (C) The number of pixels included at each threshold (expressed as a % of the total number of pixels in the image) was calculated. The table shows: the average threshold amounts for each group; the raw difference between the groups; the between group difference expressed as a percentage of control; and the p-values for the group differences. (D) Illustrates how the column graphs would appear in a scientific report if a pixel intensity of 55 or 115 were chosen for the thresholding process. Two valid thresholding choices result in opposite scientific conclusions on the experimental intervention. Scale bar = 30 μm.
Figure 2Illustrates the standard thresholding process and its adaption to create the cumulative threshold spectra. Panel (A) illustrates standard thresholding. A hypothetical 16 pixel 24 bit color image (left) is converted into an 8 bit greyscale image (middle). The greyscale image is thresholded at pixel intensity 50 to create a black (0) and white (1) binary image (right). Panels (B–C) illustrate the cumulative threshold spectra. Instead of simply determining the number of pixels at or below a single threshold the cumulative threshold spectra involves determining the amount of material included at each of the four possible thresholding cut-points. Panel (B) specifically illustrates the calculations used to create the histogram and cumulative threshold percentages. (C) Using the data presented in panel B, a pixel intensity histogram has been created (left) and the number of pixels occurring at each of the pixel intensities is presented graphically as a cumulative threshold spectra (right). Panel (D) represents the average pixel intensity histograms (±) SEM for an actual set of data representing the images as considered in Fig 1 derived from two groups of animals. (E) The left image illustrates the average cumulative threshold spectra (±) SEM for the control and intervention groups. The valid threshold range (TR, as identified in Fig. 1) is indicated by two vertical dashed lines bisecting the horizontal axis at pixel intensities 55 and 115. From the cumulative threshold spectra we can create a % difference plot, the middle image on panel E, which displays the same information in a different way. The % differences plot shows directly how a percent difference measure would vary as the threshold is varied. In the right most image of panel E is presented the probability values, which would have been derived from independent samples t-tests (2 tailed) for each of the 256 possible thresholding levels. The dotted red line again indicates the 0.05 significance level. In the case of our GFAP example we find that 36 of a total of 61 possible threshold levels within the valid threshold range are statistically significant (at the 0.05 level).