| Literature DB >> 26062811 |
Tomoaki Tamaki1, Tatsuya Ohno2, Shin-ei Noda2, Shingo Kato3, Takashi Nakano2.
Abstract
This study aimed to provide accurate dose distribution profiles of radiotherapy for cervical cancer when treated with the central shielding technique by analysing the composite 3D EQD2 dose distribution of external beam radiotherapy (EBRT) plus intracavitary brachytherapy (ICBT). On a phantom, four patterns of the combinations of whole pelvis irradiation (WP) (4 fields), pelvis irradiation with central shielding technique (CS) [anterior-posterior/posterior-anterior (AP-PA fields), shielding width of 3 or 4 cm] and ICBT using Point-A prescription were created: 30 Gy/15 fractions + 20 Gy/10 fractions + 24 Gy/4 fractions [Plan (30 + 20 + 24)], 40 Gy/20 fractions + 10 Gy/5 fractions + 18 Gy/3 fractions [Plan (40 + 10 + 18)], 40 Gy/20 fractions + 10 Gy/5 fractions + 24 Gy/4 fractions [Plan (40 + 10 + 24)] and 45 Gy/25 fractions + 0 Gy + 28 Gy/4 fractions [Plan (45 + 0 + 28)]. The composite EQD2 dose distributions of the complete treatment were analysed. The Point-A dose of Plan (30 + 20 + 24), Plan (40 + 10 + 18), Plan (40 + 10 + 24) and Plan (45 + 0 + 28) were 78.0 Gy (CS 3 cm)/71.8 Gy (CS 4 cm), 72.1 Gy (CS 3 cm)/69.0 Gy (CS 4 cm), 80.1 Gy (CS 3 cm)/77.0 Gy (CS 4 cm) and 84.1 Gy, whereas it has been previously reported to be 62 Gy, 64 Gy, 72 Gy and 84 Gy, respectively. For all the treatment plans with CS, equivalent or wider coverage of 60 Gy (EQD2) was achieved in the right-left direction, while coverage in the anterior-posterior direction decreased in plans with CS. There were no irregularly 'cold' regions around the central target. The use of CS in radiotherapy for cervical cancer resulted in tumor coverage in the lateral direction with doses higher than the previously reported Point-A doses.Entities:
Keywords: EQD2; brachytherapy; central shielding; cervical cancer; radiotherapy
Mesh:
Year: 2015 PMID: 26062811 PMCID: PMC4576998 DOI: 10.1093/jrr/rrv029
Source DB: PubMed Journal: J Radiat Res ISSN: 0449-3060 Impact factor: 2.724
Summary of combinations of whole pelvis irradiation (WP), pelvis irradiation with central shielding technique (CS) and brachytherapy (BT) analysed in this study
| Plan (30 + 20 + 24) [ | Plan (40 + 10 + 18) [ | Plan (40 + 10 + 24) [ | Plan (45 + 0 + 28) [3, 10a] | |
|---|---|---|---|---|
| WP | 30 Gy/15 fr | 40 Gy/20 fr | 40 Gy/20 fr | 45 Gy/25 fr |
| CS | 20 Gy/10 fr | 10 Gy/5 fr | 10 Gy/5 fr | 0 Gy |
| BT | 24 Gy/4 fr | 18 Gy/3 fr | 24 Gy/4 fr | 28 Gy/4 fr |
| Previously reported total Point-A dose (EQD2) | 62 Gy | 64 Gy | 72 Gy | ∼84 Gy |
aHR-CTV D90 prescription.
Fig. 1.(a) The composite EQD2 dose distributions of WP 30 Gy/15 fractions + CS 20 Gy/10 fractions + BT 24 Gy/4 fractions (CS 3 cm) and WP 45 Gy/25 fractions + BT 28 Gy/4 fractions. The composite EQD2 distributions on the axial and coronal images at the level of Point A are shown. (b) The doses of EBRT and ICBT and the total dose in EQD2 on the RL axis [blue lines in (a)] and on the AP axis [red lines in (a)] are shown.
Fig. 2.(a) The composite EQD2 dose distributions of WP 30 Gy/15 fractions + CS 20 Gy/10 fractions + BT 24 Gy/4 fractions (CS 3 or 4 cm) (far left column), WP 40 Gy/20 fractions + CS 10 Gy/5 fractions + BT 18 Gy/3 fractions (CS 3 or 4 cm) (near left column), WP 40 Gy/20 fractions + CS 10 Gy/5 fractions + BT 24 Gy/4 fractions (CS 3 or 4 cm) (near right column) and WP 45 Gy/25 fractions + BT 28 Gy/4 fractions (far right column). The composite EQD2 distributions on the axial images at the level of Point A are shown. (b) The doses of EBRT and ICBT and the total dose in EQD2 on the RL axis [blue lines in (a)] and on the AP axis [red lines in (a)] are shown. The EBRT doses and the total doses of CS 4 cm (green lines) are mostly overlaid by those of CS 3 cm (red lines), except around the borders of the central shielding.
The doses at Point A, the lengths on the anterior–posterior (AP) and right–left (RL) axes covered by 50–100 Gy (EQD2) on the axial plane of Point A, and the volume covered by 50–100 Gy (EQD2)
| Plan | Plan (30 + 20 + 24) | Plan (40 + 10 + 18) | Plan (40 + 10 + 24) | Plan (45 + 0 + 28) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Center shielding width | 3 cm | 4 cm | 3 cm | 4 cm | 3 cm | 4 cm | ||||||||
| Doses at Point A | 78.0 Gy | 71.8 Gy | 72.1 Gy | 69.0 Gy | 80.1 Gy | 77.0 Gy | 84.1 Gy | |||||||
| Axis | AP | RL | AP | RL | AP | RL | AP | RL | AP | RL | AP | RL | AP | RL |
| Lengths covered by 100 Gy (cm) | 2.4 | 2.6 | 2.4 | 2.5 | 2.2 | 2.3 | 2.2 | 2.2 | 2.7 | 2.8 | 2.7 | 2.7 | 3.2 | 3.2 |
| Lengths covered by 90 Gy (cm) | 2.7 | 3.0 | 2.7 | 2.8 | 2.5 | 2.6 | 2.5 | 2.5 | 3.0 | 3.3 | 3.0 | 3.1 | 3.6 | 3.7 |
| Lengths covered by 80 Gy (cm) | 3.0 | 3.8 | 3.0 | 3.2 | 2.9 | 3.2 | 2.9 | 3.0 | 3.4 | 4.0 | 3.4 | 3.7 | 4.1 | 4.3 |
| Lengths covered by 70 Gy (cm) | 3.5 | 5.2 | 3.5 | 4.5 | 3.4 | 4.3 | 3.4 | 3.9 | 4.1 | 5.3 | 4.1 | 5.2 | 5.0 | 5.3 |
| Lengths covered by 60 Gy (cm) | 4.2 | 8.2 | 4.2 | 8.2 | 4.5 | 7.0 | 4.4 | 6.9 | 5.3 | 8.3 | 5.3 | 8.3 | 6.7 | 7.1 |
| Lengths covered by 50 Gy (cm) | 5.4 | >12 | 5.4 | >12 | 7.0 | >12 | 6.9 | >12 | 8.2 | >12 | 8.1 | >12 | 11.2 | >12 |
| Volume covered by 100 Gy (cm3) | 47.7 | 45.5 | 38.9 | 38.0 | 54.2 | 52.8 | 70.9 | |||||||
| Volume covered by 90 Gy (cm3) | 59.0 | 55.4 | 48.8 | 47.3 | 68.3 | 65.9 | 88.2 | |||||||
| Volume covered by 80 Gy (cm3) | 77.9 | 71.0 | 65.2 | 62.3 | 92.3 | 87.5 | 116.2 | |||||||
| Volume covered by 70 Gy (cm3) | 118.1 | 101.7 | 99.1 | 91.5 | 143.2 | 132.1 | 169.1 | |||||||
| Volume covered by 60 Gy (cm3) | 266.3 | 221.3 | 218.9 | 192.4 | 329.1 | 296.5 | 305.5 | |||||||
| Volume covered by 50 Gy (cm3) | 2389.4 | 2228.9 | 2464.5 | 2333.8 | 2609.2 | 2489.1 | 1257.7 | |||||||