Literature DB >> 26060380

Percutaneous Transcatheter Closure of Ruptured Sinus of Valsalva Aneurysm: Immediate Result and Long-Term Follow-Up.

Sudhir Chandra Sinha1, Vipperla Sujatha1, Anil Kumar Mahapatro1.   

Abstract

There is scarcity of data on closure and long-term follow-up of percutaneous treatment of ruptured sinus of Valsalva aneurysm (RSOVA). In this article, we present our experience in percutaneous closure of this defect. Between December 2009 and July 2014, 11 cases of RSOVA were referred to our hospital. Eight of the 11 cases (72.7%) were considered for percutaneous closure. Seven of the eight (87.5%) patients underwent successful percutaneous closure. There were four females and three males in the age group of 16 to 48 years (mean 24.7 ± 6.1 years). Associated defects were bicuspid aortic valve in one patient, mild preexisting aortic regurgitation in two patients, and healed infective endocarditis in one patient. Echocardiography revealed RSOVA from right coronary sinus (RCS) to right atrium (RA) in one patient (14.3%), RCS to right ventricular outflow in three patients (42.8%), and noncoronary sinus ruptured into RA in three patients (42.8%). All patients were symptomatic in New York Heart Association (NYHA) class II to IV. The defect size ranged from 7 to 10 mm (mean 8.4 ± 1.3 mm). The defects were closed from the venous side with device selection 2 to 4 mm higher than the defect size under fluoroscopy and transesophageal echocardiography guidance. Technical success was 87.5%. The mean device size was 12.0 ± 1.6 mm/10.0 ± 1.6 mm. Six out of seven patients (85.7%) had complete disappearance of shunt before discharge. During 1 to 55 months follow-up, all patients were in NYHA class I. There was no residual shunt, progression of AR or new AR, infective endocarditis or device embolization. Percutaneous closure of RSOVA appears to be a safe alternative to surgical therapy, with high technical success and excellent long-term outcome.

Entities:  

Keywords:  aneurysm; cardiac catheterization; cardiac device; cardiac surgery; endocarditis; endovascular procedure; percutaneous

Year:  2015        PMID: 26060380      PMCID: PMC4452606          DOI: 10.1055/s-0034-1396948

Source DB:  PubMed          Journal:  Int J Angiol        ISSN: 1061-1711


  13 in total

1.  The pathological anatomy of deficiencies between the aortic root and the heart, including aortic sinus aneurysms.

Authors:  J E EDWARDS; H B BURCHELL
Journal:  Thorax       Date:  1957-06       Impact factor: 9.139

2.  Congenital aneurysms of sinus of Valsalva. A clinical study.

Authors:  S SAKAKIBARA; S KONNO
Journal:  Am Heart J       Date:  1962-05       Impact factor: 4.749

3.  Unruptured sinus of Valsalva aneurysm.

Authors:  M C Fishbein; R Obma; W C Roberts
Journal:  Am J Cardiol       Date:  1975-06       Impact factor: 2.778

4.  Transcatheter closure of a ruptured aneurysm of the sinus of Valsalva.

Authors:  S Cullen; J Somerville; A Redington
Journal:  Br Heart J       Date:  1994-05

5.  Transcatheter closure of ruptured sinus of Valsalva aneurysm using the Amplatzer duct occluder: immediate results and mid-term follow-up.

Authors:  Prafulla G Kerkar; Charan P Lanjewar; Nidheesh Mishra; Prasanna Nyayadhish; Isaac Mammen
Journal:  Eur Heart J       Date:  2010-09-09       Impact factor: 29.983

6.  Transcatheter device closure of ruptured sinus of Valsalva: Immediate results and short term follow up.

Authors:  Supratim Sen; Amitabha Chattopadhyay; Mily Ray; Biswajit Bandyopadhyay
Journal:  Ann Pediatr Cardiol       Date:  2009-01

7.  Transcatheter closure of ruptured sinus of valsalva aneurysms with an Amplatzer occluder.

Authors:  Malgorzata Szkutnik; Jacek Kusa; Jan Glowacki; Roland Fiszer; Jacek Bialkowski
Journal:  Rev Esp Cardiol       Date:  2009-11       Impact factor: 4.753

8.  Transcatheter closure of ruptured sinus of valsalva aneurysm.

Authors:  Ramesh Arora; Vijay Trehan; Uma Mahesh C Rangasetty; Saibal Mukhopadhyay; Ashish K Thakur; G S Kalra
Journal:  J Interv Cardiol       Date:  2004-02       Impact factor: 2.279

9.  Percutaneous device closure of ruptured sinus of valsalva aneurysm: a preliminary experience.

Authors:  Lihua Guan; Daxin Zhou; Feng Zhang; Wenzhi Pan; Lili Dong; Haiyan Chen; Junbo Ge
Journal:  J Invasive Cardiol       Date:  2013-10       Impact factor: 2.022

10.  Transcatheter occlusion of ruptured sinus of valsalva aneurysm: innovative use of available technology.

Authors:  P Syamasundar Rao; Burt I Bromberg; Saadeh B Jureidini; Andrew C Fiore
Journal:  Catheter Cardiovasc Interv       Date:  2003-01       Impact factor: 2.692

View more
  4 in total

1.  Sinus of Valsalva Aneurysm: A Rare Cause of Dyspnea.

Authors:  Aiman Smer; Osama Elsallabi; Mohamed Ayan; Haitam Buaisha; Hamza Rayes; Yazeid Alshebani; Hamza Tantoush; Mohsin Salih
Journal:  Case Rep Med       Date:  2015-08-24

2.  Ruptured sinus of Valsalva aneurysms - our surgical experience of 7 years.

Authors:  Abhishek Shrinivas Joshi; Balaji Dattatray Aironi; Ninad Sunil Kotkar; Dwarkanath Vivekanand Kulkarni; Uday Eknath Jadhav; Ketak Mahendra Nagare
Journal:  Kardiochir Torakochirurgia Pol       Date:  2021-07-05

3.  Transthoracic minimally invasive closure for the treatment of ruptured sinus of Valsalva aneurysm: immediate and mid-term follow-up results.

Authors:  Shixiong Wang; Debin Liu; Yongnan Li; Shiqun Wu; Weifan Wang; Qi Ma; Yunjiao Li; Wenli Wang; Bingren Gao
Journal:  J Thorac Dis       Date:  2022-01       Impact factor: 2.895

4.  Safety and Feasibility of Transcatheter Interruption of Ruptured Sinus of Valsalva Aneurysm Using the Cocoon Duct Occluder: Immediate Results and Mid-Term Follow-Up.

Authors:  Santosh Kumar Sinha; Narendra Nath Khanna; Mahmadula Razi; Vinay Krishna; Mukesh Jitendra Jha; Vikas Mishra; Puneet Aggarwal; Amit Goel; Karandeep Singh; Ramesh Thakur; Lawrence Rajan; Chandra Mohan Varma
Journal:  Cardiol Res       Date:  2017-08-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.