Literature DB >> 26057897

Measurement of prompt gamma profiles in inhomogeneous targets with a knife-edge slit camera during proton irradiation.

M Priegnitz1, S Helmbrecht, G Janssens, I Perali, J Smeets, F Vander Stappen, E Sterpin, F Fiedler.   

Abstract

Proton and ion beam therapies become increasingly relevant in radiation therapy. To fully exploit the potential of this irradiation technique and to achieve maximum target volume conformality, the verification of particle ranges is highly desirable. Many research activities focus on the measurement of the spatial distributions of prompt gamma rays emitted during irradiation. A passively collimating knife-edge slit camera is a promising option to perform such measurements. In former publications, the feasibility of accurate detection of proton range shifts in homogeneous targets could be shown with such a camera. We present slit camera measurements of prompt gamma depth profiles in inhomogeneous targets. From real treatment plans and their underlying CTs, representative beam paths are selected and assembled as one-dimensional inhomogeneous targets built from tissue equivalent materials. These phantoms have been irradiated with monoenergetic proton pencil beams. The accuracy of range deviation estimation as well as the detectability of range shifts is investigated in different scenarios. In most cases, range deviations can be detected within less than 2 mm. In close vicinity to low-density regions, range detection is challenging. In particular, a minimum beam penetration depth of 7 mm beyond a cavity is required for reliable detection of a cavity filling with the present setup. Dedicated data post-processing methods may be capable of overcoming this limitation.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26057897     DOI: 10.1088/0031-9155/60/12/4849

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Prompt gamma imaging for the identification of regional proton range deviations due to anatomic change in a heterogeneous region.

Authors:  Yunhe Xie; Johannes Petzoldt; Guillaume Janssens; Fionnbarr O'Grady; Lingshu Yin; El Hassane Bentefour; Julien Smeets; Damien Prieels; Robert A Lustig; Alexander Lin; Boon-Keng Teo
Journal:  Br J Radiol       Date:  2020-10-06       Impact factor: 3.039

2.  Assessment of Geant4 Prompt-Gamma Emission Yields in the Context of Proton Therapy Monitoring.

Authors:  Marco Pinto; Denis Dauvergne; Nicolas Freud; Jochen Krimmer; Jean M Létang; Etienne Testa
Journal:  Front Oncol       Date:  2016-01-28       Impact factor: 6.244

3.  Towards machine learning aided real-time range imaging in proton therapy.

Authors:  Jorge Lerendegui-Marco; Javier Balibrea-Correa; Víctor Babiano-Suárez; Ion Ladarescu; César Domingo-Pardo
Journal:  Sci Rep       Date:  2022-02-17       Impact factor: 4.379

Review 4.  Compton Camera and Prompt Gamma Ray Timing: Two Methods for In Vivo Range Assessment in Proton Therapy.

Authors:  Fernando Hueso-González; Fine Fiedler; Christian Golnik; Thomas Kormoll; Guntram Pausch; Johannes Petzoldt; Katja E Römer; Wolfgang Enghardt
Journal:  Front Oncol       Date:  2016-04-12       Impact factor: 6.244

5.  Experimental Comparison of Knife-Edge and Multi-Parallel Slit Collimators for Prompt Gamma Imaging of Proton Pencil Beams.

Authors:  Julien Smeets; Frauke Roellinghoff; Guillaume Janssens; Irene Perali; Andrea Celani; Carlo Fiorini; Nicolas Freud; Etienne Testa; Damien Prieels
Journal:  Front Oncol       Date:  2016-06-27       Impact factor: 6.244

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.