Literature DB >> 26056185

Bundled preparation of skin antisepsis decreases the risk of cardiac implantable electronic device-related infection.

Huang-Chung Chen1, Mien-Cheng Chen2, Yung-Lung Chen1, Tzu-Hsien Tsai1, Kuo-Li Pan3, Yu-Sheng Lin3.   

Abstract

AIMS: To evaluate the efficacy of bundled skin antiseptic preparation to prevent cardiac implantable electronic device (CIED) infections. METHODS AND
RESULTS: From January 2010 to November 2013, 665 consecutive patients were divided into two groups according to the strategy of skin preparation. In Period 1 (January 2010 to June 2012), 395 patients received the standard skin antiseptic preparation. In Period 2 (July 2012 to November 2013), 270 patients received a triple-step skin antiseptic preparation, 'bundled skin antiseptic preparation', consisting of applying 75% alcohol over anterior chest on the night before the index day, povidone-iodine 10 min before operation, and the standard skin antiseptic preparation before incision. During follow-up, the occurrence of CIED infection was recorded. Multiple logistic regression analysis was used to determinate the risk factors of CIED infection. During a mean follow-up of 26.9 ± 16.2 months, 20 episodes of CIED infection developed in 19 patients (2.9%), and the incidence of minor and major infection episodes was 2.2% and 0.8%, respectively. Patients with the bundled skin antiseptic preparation had a significantly lower incidence of CIED infection, compared with patients with the standard preparation (0.7 vs. 4.3%, P = 0.007). In multivariate analysis, pocket haematoma (P = 0.020), atrial fibrillation (P = 0.033), and complex procedures (P = 0.047) were independent predictors for CIED infection. In contrast, the bundled skin antiseptic preparation was a significant predictor against CIED infection (P = 0.014).
CONCLUSION: Pocket haematoma was the most important risk factor for CIED infection. The bundled skin antiseptic preparation strategy significantly reduced the risk of minor CIED infection. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2015. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Cardiac device infection; Cardiac implantable electronic devices; Skin antiseptic preparation

Mesh:

Substances:

Year:  2015        PMID: 26056185     DOI: 10.1093/europace/euv139

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  3 in total

1.  Real-world effectiveness of infection prevention interventions for reducing procedure-related cardiac device infections: Insights from the veterans affairs clinical assessment reporting and tracking program.

Authors:  Archana Asundi; Maggie Stanislawski; Payal Mehta; Anna E Baron; Hillary J Mull; P Michael Ho; Peter J Zimetbaum; Kalpana Gupta; Westyn Branch-Elliman
Journal:  Infect Control Hosp Epidemiol       Date:  2019-06-04       Impact factor: 3.254

2.  Epidemiology of cardiac implantable electronic device infections: incidence and risk factors.

Authors:  Hui-Chen Han; Nathaniel M Hawkins; Charles M Pearman; David H Birnie; Andrew D Krahn
Journal:  Europace       Date:  2021-06-23       Impact factor: 5.214

3.  Diabetes Increases Risk of Cardiovascular Events in Patients Receiving Permanent Pacemaker: A Propensity Score-Matched Cohort Study.

Authors:  Huang-Chung Chen; Wen-Hao Liu; Chien-Hao Tseng; Yung-Lung Chen; Wei-Chieh Lee; Yen-Nan Fang; Shaur-Zheng Chong; Mien-Cheng Chen
Journal:  J Diabetes Res       Date:  2022-03-28       Impact factor: 4.011

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.