Literature DB >> 26051867

Reconstruction of the orbital floor with polydioxanone: a long-term clinical survey of up to 12 years.

Benedicta Elisabeth Beck-Broichsitter1, Carolin Acar2, Christian Kandzia3, Arne Jochens4, Jörg Wiltfang5, Stephan T Becker6.   

Abstract

Fractures of the orbital floor are common in injured patients, who often require operation to prevent complications and, among other materials, polydioxanone is widely used. The aim of this study was to evaluate the long-term outcomes of fractures of the orbital floor that had been reconstructed with polydioxanone foil. A total of 101 patients (73 men and 28 women) who had reconstruction of the orbital floor for defects of 2cm(2) or smaller with polydioxanone implants, over a mean (SD) time period of 8 (2) years were evaluated. Sensitivity of the infraorbital nerve, ocular motility, and diplopia were evaluated and correlated with perioperative values. Persistent hyperaesthesia was found in 15 patients, whereas in another 15 the hyperaesthesia recovered completely over time. Three patients had double vision during follow-up. Twenty patients with preoperative diplopia had no persistent double vision postoperatively, and 15 patients with disturbed ocular motility recovered completely. Two patients had persistently disturbed motility, and one patient had enophthalmos. There was a significant association between hyperaesthesia preoperatively and postoperatively (p= 0.005). In most patients reconstruction of the orbital floor with polydioxanone was successful. Long-term complications such as diplopia, compromised bulbar motility, and hyperaesthesia of the cheek were seen in a few cases, but might not have been solely related to the use of polydioxanone.
Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Diplopia; Enopthalmos; Hypesthaesia; Orbital floor fracture; Polydioxanone

Mesh:

Substances:

Year:  2015        PMID: 26051867     DOI: 10.1016/j.bjoms.2015.05.010

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  3 in total

1.  Clinical Outcome Following Surgical Repair of Small Versus Large Orbital Floor Fractures Using Polyglactin 910/Polydioxanone (Ethisorb®).

Authors:  Otto Steinmassl; Johannes Laimer; Vincent Offermanns; Matthias Wildauer; Patricia-Anca Steinmassl; Astrid E Grams; Ferdinand Kofler; Michael Rasse; Emanuel Bruckmoser
Journal:  Materials (Basel)       Date:  2020-01-03       Impact factor: 3.623

2.  Repair of unilateral combined orbital floor and medial wall fracture using two titanium mesh plates: a modified technique.

Authors:  Jinguo Yu; Jingkai Zhang; Song Chen; Qi Han; Hua Yan
Journal:  Ann Transl Med       Date:  2021-03

Review 3.  Orbital pathology - Iatrogenic findings and artefacts.

Authors:  Caroline Thaung
Journal:  Saudi J Ophthalmol       Date:  2018-02-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.