Literature DB >> 26048822

A novel mixed-mode solid phase extraction coupled with LC-MS/MS for the re-evaluation of free 3-nitrotyrosine in human plasma as an oxidative stress biomarker.

Xiaoguang Sunny Li1, Shu Li2, Gottfried Kellermann3.   

Abstract

3-Nitrotyrosine (3-NT) has been widely adopted as a biomarker of oxidative stress. However, an enormous range of reported concentrations of 3-NT in biological matrices indicated an underlying methodological problem. Consequently, our understanding of tyrosine nitration in vivo and its significance as a biomarker may have been confounded. Here we report a fast, specific and sensitive LC-MS/MS method to accurately quantify free 3-NT in human plasma. For the first time, a single-step solid phase extraction of 3-NT using mixed-mode sorbent in a 96-well plate was developed after significant optimization. Complete chromatographic separation of 3-NT from other tyrosine analogs was achieved on a PFPP column (150 mm, 2.1 mm, 3 μm) with a cycle time of 10 min. The developed method was validated in terms of linearity, sensitivity, specificity, precision, accuracy, matrix effect, carryover, analyte stability and reference interval. The lower limit of quantification of the method was 5 pg/ml for plasma 3-NT, which represents a significant sensitivity improvement over reported methods. No artifactual 3-NT formation was observed, and the assay was not affected by 40 likely interferences. The average intra- and inter-assay variances were 3.4% and 3.7%, respectively. Of note, the reference interval for a healthy population was established to be 2.0-40.1 pg/ml (8.8-177 pM) with a mean of 11.1 pg/ml (49 pM). The mean value is at least 13-fold lower than previously reported mean values. Furthermore, the method was applied to the investigation of biological variation (n=15) over a three week period and no statistical differences were found. The solid phase extraction in a 96-well format and a fast LC-MS/MS delivered a practical, precise and accurate tool well-suited to quantify free plasma 3-NT in a large number of biological samples.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  3-Nitrotyrosine; LC–MS/MS; Method validation; Mixed-mode solid phase extraction; Oxidative stress biomarker; Plasma

Mesh:

Substances:

Year:  2015        PMID: 26048822     DOI: 10.1016/j.talanta.2015.02.053

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

Review 1.  Tyrosine-Nitrated Proteins: Proteomic and Bioanalytical Aspects.

Authors:  Carlos Batthyány; Silvina Bartesaghi; Mauricio Mastrogiovanni; Analía Lima; Verónica Demicheli; Rafael Radi
Journal:  Antioxid Redox Signal       Date:  2016-07-22       Impact factor: 8.401

2.  Role of Peroxiredoxin 2 in the Protection Against Ferrous Sulfate-Induced Oxidative and Inflammatory Injury in PC12 Cells.

Authors:  Wenzhe Xu; Feng Li; Zhenkuan Xu; Bin Sun; Jingwei Cao; Yuguang Liu
Journal:  Cell Mol Neurobiol       Date:  2017-09-04       Impact factor: 5.046

3.  Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications.

Authors:  Xiaoguang Sunny Li; Shu Li; Melissa Ahrens; Gottfried Kellermann
Journal:  J Vis Exp       Date:  2017-07-14       Impact factor: 1.355

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.