Sensitive gluten determination in gluten-free foods by an electrochemical aptamer-based assay.

Sonia Amaya-González1, Noemí de-Los-Santos-Álvarez, Arturo J Miranda-Ordieres, María Jesús Lobo-Castañón.   

Abstract

Enzyme immunoassays are currently the methods of choice for gluten control in foods labelled as gluten free, providing a mechanism for assessing food safety for consumption by coeliac and other allergic patients. However, their limitations, many of them associated to the reactivity of the different antibodies used and their degree of specificity, have prevented the establishment of a standardised method of analysis. We explore new methods for quantitatively determining gluten content in foods based on the use of two recently described aptamers, raised against a 33-mer peptide recognised as the immunodominant fragment from α2-gliadin. The assays use the target peptide immobilised onto streptavidin-coated magnetic beads in combination with a limited amount of biotin-aptamer in a competitive format, followed by streptavidin-peroxidase labelling of the aptamer that remains bound to the magnetic beads. The enzyme activity onto the beads, measured by chronoamperometry in disposable screen-printed electrodes, is inversely related to the target concentration in the test solution. We find that while the assay using the aptamer with the highest affinity towards the target (Gli 4) achieves low detection limits (~0.5 ppm) and excellent analytical performance, when challenged in samples containing the intact protein, gliadin, it fails in detecting the peptide in solution. This problem is circumvented by employing another aptamer (Gli 1), the most abundant one in the SELEX pool, as a receptor. The proposed assays allow the convenient detection of the allergen in different kinds of food samples, including heat-treated and hydrolysed ones. The obtained results correlate with those of commercially available antibody-based assays, providing an alternative for ensuring the safety and quality of nominally gluten-free foods. Graphical Abstract Electrochemical magnetoassay for gluten determination using biotin-aptamers as receptors.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26048055     DOI: 10.1007/s00216-015-8771-6

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  6 in total

Review 1.  Recent Advances in Electrochemical Sensing Strategies for Food Allergen Detection.

Authors:  Antonella Curulli
Journal:  Biosensors (Basel)       Date:  2022-07-09

Review 2.  Harnessing Aptamers to Overcome Challenges in Gluten Detection.

Authors:  Rebeca Miranda-Castro; Noemí de-los-Santos-Álvarez; Arturo J Miranda-Ordieres; María Jesús Lobo-Castañón
Journal:  Biosensors (Basel)       Date:  2016-04-20

Review 3.  Electrochemical Affinity Biosensors Based on Disposable Screen-Printed Electrodes for Detection of Food Allergens.

Authors:  Alina Vasilescu; Gilvanda Nunes; Akhtar Hayat; Usman Latif; Jean-Louis Marty
Journal:  Sensors (Basel)       Date:  2016-11-05       Impact factor: 3.576

Review 4.  Luminescent Aptamer-Based Bioassays for Sensitive Detection of Food Allergens.

Authors:  Donato Calabria; Martina Zangheri; Seyedeh Rojin Shariati Pour; Ilaria Trozzi; Andrea Pace; Elisa Lazzarini; Maria Maddalena Calabretta; Mara Mirasoli; Massimo Guardigli
Journal:  Biosensors (Basel)       Date:  2022-08-15

5.  Aptamer-based assays: strategies in the use of aptamers conjugated to magnetic micro- and nanobeads as recognition elements in food control.

Authors:  Monica Mattarozzi; Lorenzo Toma; Alessandro Bertucci; Marco Giannetto; Maria Careri
Journal:  Anal Bioanal Chem       Date:  2021-07-10       Impact factor: 4.142

6.  Monoclonal Antibody-Based Immunosensor for the Electrochemical Detection of Chlortoluron Herbicide in Groundwaters.

Authors:  Anaïs Surribas; Lise Barthelmebs; Thierry Noguer
Journal:  Biosensors (Basel)       Date:  2021-12-13