Literature DB >> 26046997

Targeting a New Safe Zone: A Step in the Development of Patient-Specific Component Positioning for Total Hip Arthroplasty.

Alexander S McLawhorn1, Peter K Sculco, K Durham Weeks, Denis Nam, David J Mayman.   

Abstract

Surgeons often target the Lewinnek zone, with its mean (SD) inclination of 40° (10°) and mean (SD) anteversion of 15° (10°), for acetabular orientation during total hip arthroplasty (THA). However, matching native anteversion (20°-25°) may achieve optimal stability. We conducted a study in a large single-surgeon patient cohort to determine the incidence of early postoperative dislocation with increased acetabular anteversion and the accuracy of imageless navigation in achieving target acetabular position. Soft-tissue repair through a posterolateral approach was performed in 553 THAs that met the inclusion criteria. Mean (SD) target acetabular orientation was 40° (10°) of inclination and 25° (10°) of anteversion. Software was used to measure acetabular positioning on postoperative radiographs. Incidence of dislocation within 6 months after surgery was determined. Mean (SD) inclination was 42.2° (4.9°), and mean (SD) anteversion was 23.9° (6.5°). Approximately 82% of cups were placed in the target zone. Variation in anteversion accounted for 67.3% of outliers. Only body mass index was associated with inclination outside the target range (P = .017), and only female sex was associated with anteversion outside the target range (P = .030). Six THAs (1.1%) experienced early dislocation, and 3 (0.54%) of these were revised for multiple dislocations. There was no relationship between dislocation and component placement in either the Lewinnek zone (P = .224) or the target zone (P = .287).

Entities:  

Mesh:

Year:  2015        PMID: 26046997

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  8 in total

1.  Anteroposterior Radiographs Are More Accurate than Cross-Table Lateral Radiographs for Acetabular Anteversion Assessment: a Retrospective Cohort Study.

Authors:  Peter K Sculco; Alexander S McLawhorn; Kaitlin M Carroll; Benjamin A McArthur; David J Mayman
Journal:  HSS J       Date:  2015-10-19

2.  Can an Augmented Reality Headset Improve Accuracy of Acetabular Cup Orientation in Simulated THA? A Randomized Trial.

Authors:  Kartik Logishetty; Luke Western; Ruairidh Morgan; Farhad Iranpour; Justin P Cobb; Edouard Auvinet
Journal:  Clin Orthop Relat Res       Date:  2019-05       Impact factor: 4.176

3.  Can we trust combined anteversion and Lewinnek safe zone to avoid hip prosthesis dislocation?

Authors:  Alejandro Hernández; Kushal Lakhani; Jorge H Núñez; Iñaki Mimendia; Aleix Pons; Víctor Barro
Journal:  J Clin Orthop Trauma       Date:  2021-08-08

4.  Computer Navigation for Revision Total Hip Arthroplasty Reduces Dislocation Rates.

Authors:  Abhinav K Sharma; Zlatan Cizmic; Kaitlin M Carroll; Seth A Jerabek; Wayne G Paprosky; Peter K Sculco; Alejandro Gonzalez Della Valle; Ran Schwarzkopf; David J Mayman; Jonathan M Vigdorchik
Journal:  Indian J Orthop       Date:  2022-02-24       Impact factor: 1.033

5.  Lewinnek Safe Zone References are Frequently Misquoted.

Authors:  Aonnicha Burapachaisri; Ameer Elbuluk; Edem Abotsi; Jim Pierrepont; Seth A Jerabek; Aaron J Buckland; Jonathan M Vigdorchik
Journal:  Arthroplast Today       Date:  2020-11-26

Review 6.  Clinical outcomes and complication profile of total hip arthroplasty after lumbar spine fusion: a meta-analysis and systematic review.

Authors:  James Randolph Onggo; Mithun Nambiar; Jason Derry Onggo; Kevin Phan; Anuruban Ambikaipalan; Sina Babazadeh; Raphael Hau
Journal:  Eur Spine J       Date:  2019-11-01       Impact factor: 3.134

Review 7.  Acetabular cup position and risk of dislocation in primary total hip arthroplasty.

Authors:  Kurt G Seagrave; Anders Troelsen; Henrik Malchau; Henrik Husted; Kirill Gromov
Journal:  Acta Orthop       Date:  2016-11-23       Impact factor: 3.717

8.  Trigonometric Algorithm Defining the True Three-Dimensional Acetabular Cup Orientation: Correlation Between Measured and Calculated Cup Orientation Angles.

Authors:  T E Snijders; T P C Schlösser; S M van Gaalen; R M Castelein; H Weinans; A de Gast
Journal:  JB JS Open Access       Date:  2018-07-12
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.