Literature DB >> 26046707

Comparison of Measurements and Clinical Outcomes After Wavefront-Guided LASEK Between iDesign and WaveScan.

Ji Won Jung, Byung Hoon Chung, Sun Hyup Han, Eung Kweon Kim, Kyoung Yul Seo, Tae-Im Kim.   

Abstract

PURPOSE: To compare the measurements of refractive errors and ocular aberrations obtained using iDesign and WaveScan (Abbott Medical Optics, Inc., Santa Ana, CA), and to compare surgical outcomes of wavefront-guided LASEK using ablation profiles based on both aberrometers.
METHODS: Ninety myopic eyes of 45 normal patients were evaluated using both the iDesign and WaveScan to measure spherical and cylindrical errors, spherical equivalents, and Zernike coefficients of ocular aberrations. Wavefront-guided LASEK was performed in a different group of 59 eyes of 30 patients divided into two groups, the iDesign and Wavescan groups. The clinical outcomes between the two groups including uncorrected visual acuity, refractive errors, contrast sensitivity, and ocular aberration were compared at 1, 3, and 6 months postoperatively.
RESULTS: The iDesign produced significantly higher myopic values for refractive errors than the WaveScan, as well as significantly lower levels of total higher order, third, fourth, and fifth order root mean square values and Zernike coefficients of vertical coma and spherical aberration. At postoperative 1, 3, and 6 months, there were no statistically significant differences between the two groups in terms of uncorrected visual acuity and remaining refractive errors. The percentages of patients with spherical equivalents within ±1.00 and ±0.50 diopters of emmetropia were 100% (29 eyes) and 75.9% (22 eyes), respectively, in the iDesign group and 96.7% (29 eyes) and 70.0% (21 eyes), respectively, in the WaveScan group. Mesopic contrast sensitivity values were significantly higher, and the change in root mean square values for spherical aberration was significantly lower in the iDesign group.
CONCLUSIONS: There were significant differences between the iDesign and the WaveScan in the measurements of refraction and ocular aberrations. Wavefront-guided LASEK based on an ablation profile from the iDesign demonstrated comparable refractive predictability with the WaveScan group, resulting in minimal physician adjustment and superior postoperative visual quality. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 26046707     DOI: 10.3928/1081597X-20150521-06

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  2 in total

1.  Comparative study of objective visual quality between FS-LASIK and SMART in myopia.

Authors:  Yuan Wu; Yue Huang; Shu-Han Wang; Gui-Qin Wang; Ao-Miao Yu; Shao-Zhen Zhao; Rui-Hua Wei; Rui-Bo Yang; Chen Zhang
Journal:  Int J Ophthalmol       Date:  2022-03-18       Impact factor: 1.779

2.  Visual, aberrometric, photic phenomena, and patient satisfaction after myopic wavefront-guided LASIK using a high-resolution aberrometer.

Authors:  Sarah Moussa; Alois K Dexl; Eva M Krall; Eva M Arlt; Günther Grabner; Josef Ruckhofer
Journal:  Clin Ophthalmol       Date:  2016-12-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.