Literature DB >> 26046421

Analyses of inappropriate shocks in a Spanish ICD primary prevention population: Predictors and prognoses.

Agustín Fernández-Cisnal1, Álvaro Arce-León2, Eduardo Arana-Rueda2, Moisés Rodríguez-Mañero3, Cristina González-Cambeiro3, Jose Moreno-Arribas4, Larraitz Gaztañaga5, Rocío Castillo Poyo6, Pilar Cabanas-Grandío7, Miguel A Arias8, Ana Andrés de la Huerta9, Juan Miguel Sánchez Gómez10, Luis Martínez-Sande3, Alonso Pedrote2.   

Abstract

BACKGROUND: ICDs have been demonstrated to be highly effective in the primary prevention of sudden death, but inappropriate shocks (IS) occur frequently and represent one of the most important adverse effects of ICDs. The aim of this study was to analyze IS and identify the clinical predictors and prognostic implications of ISs in a real-world primary prevention ICD population.
METHODS: This multicenter retrospective study was performed in 13 centers with experience in the field of ICD implantation (at least 30 per year) and ICD follow-up in Spain. All consecutive patients who underwent ICD implantation for primary prevention between January 2008 and May 2014 were included.
RESULTS: One-thousand-sixteen patients were included, and 4 (0.39%) were lost to follow-up. Two-hundred-seventeen (21.4%) patients suffered from shock; 69 (6.8%) of these patients experienced IS, and 154 (15.4%) experienced appropriate shocks (AS). Age (<65 years, hazard ratio (HR) 2.588 [95% CI 1.282-5.225]; p=0.008), history of atrial fibrillation (HR 2.252 [95% CI 1.230-4.115]; p=0.009), non-ischemic myocardiopathy (HR 2.258 [95% CI 1.090-4.479]; p=0.028), and cardiac resynchronization therapy (HR 0.385 [95% CI 0.200-0.740]; p=0.004) were identified as IS predictors in a multivariate analysis. IS was not associated with rehospitalization due to heart failure, myocardial infarction, cardiovascular mortality or all-cause mortality.
CONCLUSIONS: This analysis of our national registry identified the independent IS predictors of age, atrial fibrillation history and cardiac resynchronization therapy and suggests that ISs are not linked to poorer clinical endpoints.
Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Implantable cardioverter device; Inappropriate shock; Primary prevention

Mesh:

Year:  2015        PMID: 26046421     DOI: 10.1016/j.ijcard.2015.05.146

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  5 in total

1.  Determinants of inappropriate implantable cardioverter-defibrillator shocks: the German Device Registry perspective.

Authors:  Erdal Safak; Lars Eckardt; Werner Jung; Hüseyin Ince; Jochen Senges; Matthias Hochadel; Christian Perings; Stefan Spitzer; Johannes Brachmann; Karlheinz Seidl; Hans Ulrich Hink; Giuseppe D'Ancona
Journal:  J Interv Card Electrophysiol       Date:  2019-08-02       Impact factor: 1.900

2.  European Heart Rhythm Association (EHRA)/Heart Rhythm Society (HRS)/Asia Pacific Heart Rhythm Society (APHRS)/Latin American Heart Rhythm Society (LAHRS) expert consensus on risk assessment in cardiac arrhythmias: use the right tool for the right outcome, in the right population.

Authors:  Jens Cosedis Nielsen; Yenn-Jiang Lin; Marcio Jansen de Oliveira Figueiredo; Alireza Sepehri Shamloo; Alberto Alfie; Serge Boveda; Nikolaos Dagres; Dario Di Toro; Lee L Eckhardt; Kenneth Ellenbogen; Carina Hardy; Takanori Ikeda; Aparna Jaswal; Elizabeth Kaufman; Andrew Krahn; Kengo Kusano; Valentina Kutyifa; Han S Lim; Gregory Y H Lip; Santiago Nava-Townsend; Hui-Nam Pak; Gerardo Rodríguez Diez; William Sauer; Anil Saxena; Jesper Hastrup Svendsen; Diego Vanegas; Marmar Vaseghi; Arthur Wilde; T Jared Bunch; Alfred E Buxton; Gonzalo Calvimontes; Tze-Fan Chao; Lars Eckardt; Heidi Estner; Anne M Gillis; Rodrigo Isa; Josef Kautzner; Philippe Maury; Joshua D Moss; Gi-Byung Nam; Brian Olshansky; Luis Fernando Pava Molano; Mauricio Pimentel; Mukund Prabhu; Wendy S Tzou; Philipp Sommer; Janice Swampillai; Alejandro Vidal; Thomas Deneke; Gerhard Hindricks; Christophe Leclercq
Journal:  Europace       Date:  2020-08-01       Impact factor: 5.214

Review 3.  Predictors of mortality and ICD shock therapy in primary prophylactic ICD patients-A systematic review and meta-analysis.

Authors:  Leonard Bergau; Tobias Tichelbäcker; Barbora Kessel; Lars Lüthje; Thomas H Fischer; Tim Friede; Markus Zabel
Journal:  PLoS One       Date:  2017-10-17       Impact factor: 3.240

4.  Changing place, changing future: Repositioning a subcutaneous implantable cardioverter-defibrillator can resolve inappropriate shocks secondary to myopotential oversensing.

Authors:  Paola Berne; Graziana Viola; Giovanni Motta; Nicola Marziliano; Valerio Carboni; Gavino Casu
Journal:  HeartRhythm Case Rep       Date:  2017-08-01

5.  Primary Prevention Implantable Cardiac Defibrillators: A Townsville District Perspective.

Authors:  Nathan Engstrom; Geoffrey P Dobson; Kevin Ng; Hayley L Letson
Journal:  Front Cardiovasc Med       Date:  2020-10-27
  5 in total