Literature DB >> 26044774

Impact of preanalytical factors on fecal immunochemical tests: need for new strategies in comparison of methods.

Tiziana Rubeca1, Filippo Cellai, Massimo Confortini, Callum G Fraser, Stefano Rapi.   

Abstract

BACKGROUND: Harmonization of fecal immunochemical tests for hemoglobin (FIT-Hb) is crucial to compare clinical outcomes in screening programs. The lack of reference materials and standard procedures does not allow the use of usual protocols to compare methods. We propose 2 protocols, based on artificial biological samples (ABS), to discriminate preanalytical and analytical variation and investigate clinical performances. The protocols were used to compare 2 FIT systems available on European markets: the OC-Sensor Diana (Eiken, Tokyo, Japan) and HM-JACKarc (Kyowa-Medex, Tokyo, Japan).
METHODS: ABS were obtained adding Hb to Hb-free feces. In the first procedure, 35 ABS were collected for each collection device and analyzed on both systems. In the second, 188 ABS (106 positive and 82 negative) were -collected and tested on the specific systems. Passing-Bablock (PB), Pearson's correlation coefficients (R) and Bland-Altman difference analysis were used to compare data.
RESULTS: PB, R and mean standard errors for Bland-Altman analysis (Diana vs. Arc) results were 0.93x-0.56: R = 0.97 and 19%; and 1.09x + 5.60: R = 0.96 and -18%; for Diana and Arc devices, respectively. No correlations and no difference in positive/negative assessment were observed with the second protocol.
CONCLUSIONS: A good correlation was observed in comparing data generated using collection devices on the 2 systems. Manufacturers have developed different sample collection procedures for feces: therefore, data from different systems cannot easily be compared. Adoption of protocols to discriminate preanalytical and analytical variation would be a significant contribution to harmonization of FIT, facilitating data comparison and information acquisition for sample collection strategy and effect of buffers on systems.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26044774     DOI: 10.5301/jbm.5000150

Source DB:  PubMed          Journal:  Int J Biol Markers        ISSN: 0393-6155            Impact factor:   2.659


  1 in total

1.  The Fast Track FIT study: diagnostic accuracy of faecal immunochemical test for haemoglobin in patients with suspected colorectal cancer.

Authors:  James L Turvill; Daniel Turnock; Dan Cottingham; Monica Haritakis; Laura Jeffery; Annabelle Girdwood; Tom Hearfield; Alex Mitchell; Ada Keding
Journal:  Br J Gen Pract       Date:  2021-07-29       Impact factor: 6.302

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.