Literature DB >> 26043095

Single-step, paper-based concentration and detection of a malaria biomarker.

David Y Pereira1, Ricky Y T Chiu1, Samantha C L Zhang1, Benjamin M Wu2, Daniel T Kamei3.   

Abstract

The lateral-flow immunoassay (LFA) is an inexpensive and rapid paper-based assay that can potentially detect infectious disease biomarkers in resource-poor settings. Despite its many advantages that make it suitable for point-of-care diagnosis, LFA is limited by its inferior sensitivity relative to sophisticated laboratory-based assays. Our group previously introduced the use of a micellar aqueous two-phase system (ATPS), comprised of the nonionic Triton X-114 surfactant, to concentrate biomarkers in a sample and enhance their detection with LFA. However, achieving complete phase separation and target concentration using the Triton X-114 system required many hours, and the concentrated sample needed to be manually extracted and applied to LFA. Here, we successfully integrated the concentration and detection steps into a single step that occurs entirely within a portable paper-based diagnostic strip. In a novel approach, we applied the micellar ATPS to a 3-D paper design and effectively reduced the macroscopic phase separation time from 8 h to approximately 3 min. The 3-D design was integrated with LFA to simultaneously concentrate and detect Plasmodium lactate dehydrogenase (pLDH), a malaria biomarker, in both phosphate-buffered saline and fetal bovine serum within 20 min at room temperature. Compared to a conventional LFA setup with a pLDH detection limit of 10 ng μL(-1), our single-step diagnostic successfully detected pLDH at 1.0 ng μL(-1), demonstrating a 10-fold detection limit improvement and resulting in a sensitive and user-friendly assay that can be used at the point-of-care. The integration of a micellar ATPS and LFA represents a new platform that can improve and promote the use of paper-based diagnostic assays for malaria and other diseases within resource-poor settings.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Diagnostic; Lateral-flow immunoassay; Malaria; Micellar aqueous two-phase system; Triton X-114

Mesh:

Substances:

Year:  2015        PMID: 26043095     DOI: 10.1016/j.aca.2015.04.040

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  10 in total

Review 1.  Point-of-care diagnostics for infectious diseases: From methods to devices.

Authors:  Chao Wang; Mei Liu; Zhifei Wang; Song Li; Yan Deng; Nongyue He
Journal:  Nano Today       Date:  2021-02-06       Impact factor: 20.722

2.  Magnetically-enabled biomarker extraction and delivery system: towards integrated ASSURED diagnostic tools.

Authors:  Westley S Bauer; Danielle W Kimmel; Nicholas M Adams; Lauren E Gibson; Thomas F Scherr; Kelly A Richardson; Joseph A Conrad; Hellen K Matakala; Frederick R Haselton; David W Wright
Journal:  Analyst       Date:  2017-05-02       Impact factor: 4.616

3.  Direct transfer of HRPII-magnetic bead complexes to malaria rapid diagnostic tests significantly improves test sensitivity.

Authors:  Keersten M Ricks; Nicholas M Adams; Thomas F Scherr; Frederick R Haselton; David W Wright
Journal:  Malar J       Date:  2016-08-05       Impact factor: 2.979

Review 4.  Point-of-Care Sexually Transmitted Infection Diagnostics: Proceedings of the STAR Sexually Transmitted Infection-Clinical Trial Group Programmatic Meeting.

Authors:  Anthony D Cristillo; Claire C Bristow; Rosanna Peeling; Barbara Van Der Pol; Sasha Herbst de Cortina; Ivan K Dimov; Nitika Pant Pai; Dong Jin Shin; Ricky Y T Chiu; Catherine Klapperich; Purnima Madhivanan; Sheldon R Morris; Jeffrey D Klausner
Journal:  Sex Transm Dis       Date:  2017-04       Impact factor: 2.830

Review 5.  Lateral flow assays for viruses diagnosis: Up-to-date technology and future prospects.

Authors:  Bahar Ince; Mustafa Kemal Sezgintürk
Journal:  Trends Analyt Chem       Date:  2022-07-05       Impact factor: 14.908

Review 6.  Advanced Signal-Amplification Strategies for Paper-Based Analytical Devices: A Comprehensive Review.

Authors:  Thi Xoan Hoang; Le Minh Tu Phan; Thuy Anh Thu Vo; Sungbo Cho
Journal:  Biomedicines       Date:  2021-05-12

Review 7.  Malaria and the 'last' parasite: how can technology help?

Authors:  Ngoc Minh Pham; Walter Karlen; Hans-Peter Beck; Emmanuel Delamarche
Journal:  Malar J       Date:  2018-07-11       Impact factor: 2.979

8.  Improvement in Detection Limit for Lateral Flow Assay of Biomacromolecules by Test-Zone Pre-enrichment.

Authors:  Yi Zhang; Xiao Liu; Lingling Wang; Hanjie Yang; Xiaoxiao Zhang; Chenglong Zhu; Wenlong Wang; Lijing Yan; Bowei Li
Journal:  Sci Rep       Date:  2020-06-15       Impact factor: 4.379

9.  Ionic Liquid Aqueous Two-Phase Systems for the Enhanced Paper-Based Detection of Transferrin and Escherichia coli.

Authors:  Matthew F Yee; Grace N Emmel; Eric J Yang; Eumene Lee; Justin H Paek; Benjamin M Wu; Daniel T Kamei
Journal:  Front Chem       Date:  2018-10-16       Impact factor: 5.221

10.  Direct Diagnostic Tests for Lyme Disease.

Authors:  Steven E Schutzer; Barbara A Body; Jeff Boyle; Bernard M Branson; Raymond J Dattwyler; Erol Fikrig; Noel J Gerald; Maria Gomes-Solecki; Martin Kintrup; Michel Ledizet; Andrew E Levin; Michael Lewinski; Lance A Liotta; Adriana Marques; Paul S Mead; Emmanuel F Mongodin; Segaran Pillai; Prasad Rao; William H Robinson; Kristian M Roth; Martin E Schriefer; Thomas Slezak; Jessica L Snyder; Allen C Steere; Jan Witkowski; Susan J Wong; John A Branda
Journal:  Clin Infect Dis       Date:  2019-03-05       Impact factor: 9.079

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.