Literature DB >> 26041505

Polymer-Free Drug-Eluting Stents: An Overview of Coating Strategies and Comparison with Polymer-Coated Drug-Eluting Stents.

Weiluan Chen1, Tom C J Habraken1, Wim E Hennink1, Robbert J Kok1.   

Abstract

Clinical evaluations have proven the efficacy of drug-elution stents (DES) in reduction of in-stent restenosis rates as compared to drug-free bare metal stents (BMS). Typically, DES are metal stents that are covered with a polymer film loaded with anti-inflammatory or antiproliferative drugs that are released in a sustained manner. However, although favorable effects of the released drugs have been observed, the polymer coating as such has been associated with several adverse clinical effects, such as late stent thrombosis. Elimination of the polymeric carrier of DES may therefore potentially lead to safer DES. Several technologies have been developed to design polymer-free DES, such as the use of microporous stents and inorganic coatings that can be drug loaded. Several drugs, including sirolimus, tacrolimus, paclitaxel, and probucol have been used in the design of carrier-free stents. Due to the function of the polymeric coating to control the release kinetics of a drug, polymer-free stents are expected to have a faster drug elution rate, which may affect the therapeutic efficacy. However, several polymer-free stents have shown similar efficacy and safety as the first-generation DES, although the superiority of polymer-free DES has not been established in clinical trials.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26041505     DOI: 10.1021/acs.bioconjchem.5b00192

Source DB:  PubMed          Journal:  Bioconjug Chem        ISSN: 1043-1802            Impact factor:   4.774


  11 in total

Review 1.  Vascular Lesion-Specific Drug Delivery Systems: JACC State-of-the-Art Review.

Authors:  David Marlevi; Elazer R Edelman
Journal:  J Am Coll Cardiol       Date:  2021-05-18       Impact factor: 24.094

Review 2.  Drug-eluting stents versus bare-metal stents for acute coronary syndrome.

Authors:  Joshua Feinberg; Emil Eik Nielsen; Janette Greenhalgh; Juliet Hounsome; Naqash J Sethi; Sanam Safi; Christian Gluud; Janus C Jakobsen
Journal:  Cochrane Database Syst Rev       Date:  2017-08-23

3.  One-step grafting of temperature-and pH-sensitive (N-vinylcaprolactam-co-4-vinylpyridine) onto silicone rubber for drug delivery.

Authors:  Victor H Pino-Ramos; Carmen Alvarez-Lorenzo; Angel Concheiro; Emilio Bucio
Journal:  Des Monomers Polym       Date:  2016-09-20       Impact factor: 2.650

Review 4.  Endovascular Drug Delivery and Drug Elution Systems: First Principles.

Authors:  Abraham Rami Tzafriri; Elazer Reuven Edelman
Journal:  Interv Cardiol Clin       Date:  2016-06-21

Review 5.  Non-polymer drug-eluting coronary stents.

Authors:  Nagavendra Kommineni; Raju Saka; Wahid Khan; Abraham J Domb
Journal:  Drug Deliv Transl Res       Date:  2018-08       Impact factor: 4.617

6.  Iron-containing metal-organic framework thin film as a drug delivery system.

Authors:  Angela Bui; Steven G Guillen; Andy Sua; Travis C Nguyen; Angel Ruiz; Lester Carachure; Mark D R Weber; Araseli Cortez; Fangyuan Tian
Journal:  Colloids Surf A Physicochem Eng Asp       Date:  2022-06-30       Impact factor: 5.518

Review 7.  Polymer-free versus durable polymer drug-eluting stents in patients with coronary artery disease: A meta-analysis.

Authors:  James J Wu; Joshua A H Way; Leonard Kritharides; David Brieger
Journal:  Ann Med Surg (Lond)       Date:  2018-12-11

Review 8.  Drug-Eluting Stents and Balloons-Materials, Structure Designs, and Coating Techniques: A Review.

Authors:  I Rykowska; I Nowak; R Nowak
Journal:  Molecules       Date:  2020-10-11       Impact factor: 4.411

Review 9.  Recent Advances in Manufacturing Innovative Stents.

Authors:  Natalia Beshchasna; Muhammad Saqib; Honorata Kraskiewicz; Łukasz Wasyluk; Oleg Kuzmin; Oana Cristina Duta; Denisa Ficai; Zeno Ghizdavet; Alexandru Marin; Anton Ficai; Zhilei Sun; Vladimir F Pichugin; Joerg Opitz; Ecaterina Andronescu
Journal:  Pharmaceutics       Date:  2020-04-13       Impact factor: 6.321

Review 10.  Cardiovascular stents: overview, evolution, and next generation.

Authors:  Setareh Borhani; Shadi Hassanajili; Seyed Hossein Ahmadi Tafti; Shahram Rabbani
Journal:  Prog Biomater       Date:  2018-09-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.