The degree of acceptability of swine blood values at increasing levels of hemolysis evaluated through visual inspection versus automated quantification.

Guido Di Martino1, Anna Lisa Stefani2, Giuseppe Lippi2, Laura Gagliazzo2, Wanda McCormick2, Gianfranco Gabai2, Lebana Bonfanti2.   

Abstract

The pronounced fragility that characterizes swine erythrocytes is likely to produce a variable degree of hemolysis during blood sampling, and the free hemoglobin may then unpredictably bias the quantification of several analytes. The aim of this study was to evaluate the degree of acceptability of values obtained for several biochemical parameters at different levels of hemolysis. Progressively increased degrees of physical hemolysis were induced in 3 aliquots of 30 nonhemolytic sera, and the relative effects on the test results were assessed. To define the level of hemolysis, we used both visual estimation (on a scale of 0 to 3+) and analytical assessment (hemolytic index) and identified the best analytical cutoff values for discriminating the visual levels of hemolysis. Hemolysis led to a variable and dose-dependent effect on the test results that was specific for each analyte tested. In mildly hemolyzed specimens, C-reactive protein, haptoglobin, β1-globulin, β2-globulin, α1-globulin, γ-globulin, sodium, calcium, and alkaline phosphatase were not significantly biased, whereas α2-globulin, albumin, urea, creatinine, glucose, total cholesterol, aspartate aminotransferase, alanine aminotransferase, gamma-glutamyl transferase, nonesterified fatty acids, bilirubin, phosphorus, magnesium, iron, zinc, copper, lipase, triglycerides, lactate dehydrogenase, unbound iron-binding capacity, and uric acid were significantly biased. Chloride and total protein were unbiased even in markedly hemolyzed samples. Analytical interference was hypothesized to be the main source of this bias, leading to a nonlinear trend that confirmed the difficulty in establishing reliable coefficients of correction for adjusting the test results.
© 2015 The Author(s).

Entities:  

Keywords:  Biochemical profile; C-reactive protein; haptoglobin; hemolysis; swine

Mesh:

Substances:

Year:  2015        PMID: 26038480     DOI: 10.1177/1040638715585155

Source DB:  PubMed          Journal:  J Vet Diagn Invest        ISSN: 1040-6387            Impact factor:   1.279


  4 in total

1.  Standardizing in vitro diagnostics tasks in clinical trials: a call for action.

Authors:  Giuseppe Lippi; Ana-Maria Simundic; Leocadio Rodriguez-Manas; Patrick Bossuyt; Giuseppe Banfi
Journal:  Ann Transl Med       Date:  2016-05

2.  Effects of selenium exposure on the hematology, innate immunity, and metabolic rate of yellow-bellied sliders (Trachemys scripta scripta).

Authors:  David L Haskins; Matthew T Hamilton; Nicole I Stacy; John W Finger; Tracey D Tuberville
Journal:  Ecotoxicology       Date:  2017-08-06       Impact factor: 2.823

3.  Measuring haemolysis in cattle serum by direct UV-VIS and RGB digital image-based methods.

Authors:  Belén Larrán; Marta López-Alonso; Marta Miranda; Víctor Pereira; Lucas Rigueira; María Luisa Suárez; Carlos Herrero-Latorre
Journal:  Sci Rep       Date:  2022-08-08       Impact factor: 4.996

4.  Influence of Haemolysis on the Mineral Profile of Cattle Serum.

Authors:  Belén Larrán; Marta Miranda; Carlos Herrero-Latorre; Lucas Rigueira; Víctor Pereira; María Luisa Suárez; Marta López-Alonso
Journal:  Animals (Basel)       Date:  2021-11-23       Impact factor: 2.752

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.