Literature DB >> 26034095

Usefulness of contrast-enhanced transoesophageal echocardiography to guide thoracic endovascular aortic repair procedure.

Eustachio Agricola1, Massimo Slavich2, Enrico Rinaldi3, Luca Bertoglio3, Efrem Civilini3, Germano Melissano3, Enrico Marone3, Andrea Fisicaro2, Claudia Marini2, Vincenzo Tufaro2, Alberto Cappelletti2, Alberto Margonato2, Roberto Chiesa3.   

Abstract

AIMS: Thoracic endovascular aortic repair (TEVAR) is commonly considered as a valid alternative to surgery. Endoleaks occurrence is one of the principal limitations of TEVAR. Transoesophageal echocardiography (TEE) is often adopted in adjunct to fluoroscopy and angiography (ANGIO) during stent-graft implantation. In the present study, we compare intraprocedural ANGIO, TEE, and contrast-enhanced TEE (cTEE), and we also evaluate their accuracy in early endoleaks detection and characterization. METHODS AND
RESULTS: Fifty-four patients with thoracic aortic disease suitable for TEVAR were prospectively enrolled in the study. After stent placement, the result of the procedure was assessed by ANGIO, TEE, and cTEE. The use of contrast (Sonovue, Bracco) significantly improved TEE quality (P = 0.0001). cTEE was superior in entry tears, false and true lumen and aneurysm thrombosis identification, and microtears and ulcer-like projections detection before stent deployment. After stent deployment, cTEE was more accurate than TEE and ANGIO in the detection of slow flow in the false lumen and in the aneurismal sac (P = 0.0001), and in the remaining flow identification (P = 0.0001). Notably, cTEE is more accurate in the endoleaks detection (P = 0.0001) and in the incomplete stent expansion diagnosis and need for a further balloon inflation (P 0.002), or a further stent implantation (P 0.006), compared with TEE and ANGIO.
CONCLUSION: TEVAR procedures are improved by the complimentary use of contrast fluoroscopy, multiplane TEE with Doppler flow interrogation, and cTEE. This triple imaging approach provides additional information in all phases of the procedure improving safety of stent-grafting and the procedural outcomes. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2015. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  TEVAR; aortic disease; contrast echocardiography; transoesophageal echocardiography

Mesh:

Substances:

Year:  2015        PMID: 26034095     DOI: 10.1093/ehjci/jev118

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  3 in total

1.  Detection of inadvertent passage of guide wire into the false lumen during thoracic endovascular aortic repair of Type B aortic dissection by transesophageal echocardiography.

Authors:  Mohamed Eissa; Asadollah Mir-Ghassemi; Sudhir Nagpal; Hesham F Talab
Journal:  JA Clin Rep       Date:  2022-07-16

2.  Transesophageal Ultrasound Guidance for Endovascular Interventions on the Aorta.

Authors:  Mireya Castro-Verdes; Xun Yuan; Andreas Mitsis; Wei Li; Christoph A Nienaber
Journal:  Aorta (Stamford)       Date:  2022-05-31

3.  Aortic intervention guided by contrast-enhanced transoesophageal ultrasound whist waiting for cardiac transplantation: a case report.

Authors:  Mireya Castro Verdes; Xun Yuan; Wei Li; Roxy Senior; Christoph A Nienaber
Journal:  Eur Heart J Case Rep       Date:  2020-12-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.