Literature DB >> 26033967

Transcatheter aortic valve implantation with the new balloon-expandable Sapien 3 versus Sapien XT valve system: a propensity score-matched single-center comparison.

Freek Nijhoff1, Masieh Abawi1, Pierfrancesco Agostoni1, Faiz Z Ramjankhan1, Pieter A Doevendans1, Pieter R Stella2.   

Abstract

BACKGROUND: The new balloon-expandable Sapien 3 transcatheter heart valve (S3-THV) incorporates new features to reduce aortic regurgitation (AR) and vascular complications in transcatheter aortic valve implantation. Aim of this study is to compare the outcomes of the S3-THV with the preceding Sapien XT THV (SXT-THV) in patients who underwent transcatheter aortic valve implantation for symptomatic severe native aortic stenosis. METHODS AND
RESULTS: Eligible patients were retrospectively identified in our institutional database and periprocedural clinical and imaging data were collected. Non-parsimonious one-to-many propensity score matching was performed to account for differences in baseline characteristics. Between November 2011 and December 2014, 167 patients underwent balloon-expandable transcatheter aortic valve implantation with either the S3-THV (n=49) or SXT-THV (n=118). Forty-four (89.8%) S3-THV patients were matched to 66 (55.9%) SXT-THV patients (mean age 80.3±8.4 and 80.5±7.8 years, median EuroSCORE 15.8 and 16.5%, respectively). In the S3-THV and SXT-THV groups, transfemoral approach (77.3% versus 78.8%) and postdilatation rates (15.9% versus 12.1%) were similar. Predischarge echocardiography demonstrated a lower incidence of ≥mild AR (15.9% versus 46.2%, P=0.003) for the S3-THV, despite reduced annulus area to prosthesis oversizing (8.2±5.1 versus 18.2±10.7%, P=0.001). Transfemoral access site-related life-threatening or major bleedings and vascular complications were absent in the S3-THV group (0% versus 7.7%, P=0.15). No differences were observed in pacemaker implantation rate (9.8% versus 8.8%, P=0.94) and 30-day mortality (both 5%).
CONCLUSIONS: In this retrospective, propensity score-matched analysis, the S3-THV performed superiorly to the SXT-THV, as demonstrated by improved valve patency and increased transfemoral access safety.
© 2015 American Heart Association, Inc.

Entities:  

Keywords:  aortic regurgitation; aortic valve stenosis; transcatheter aortic valve implantation; vascular complications

Mesh:

Year:  2015        PMID: 26033967     DOI: 10.1161/CIRCINTERVENTIONS.115.002408

Source DB:  PubMed          Journal:  Circ Cardiovasc Interv        ISSN: 1941-7640            Impact factor:   6.546


  12 in total

1.  Vascular complications after transcatheter transfemoral aortic valve implantation: Modified sheath-to-femoral artery ratio as a new predictor.

Authors:  Sinem Çakal; Beytullah Çakal; Oğuz Karaca; Yeliz Güler; Özgür Ulaş Özcan; Hacı Murat Güneş; Filiz Kızılırmak Yılmaz; Arzu Yıldırım; Bilal Boztosun
Journal:  Anatol J Cardiol       Date:  2022-01       Impact factor: 1.596

2.  Choice of desflurane or propofol for the maintenance of general anesthesia does not affect the risk of periprocedural myocardial damage in patients undergoing transfemoral transcatheter aortic valve implantation.

Authors:  Kenta Okitsu; Takeshi Iritakenishi; Tatsuyuki Imada; Michioki Kuri; Sho Carl Shibata; Yuji Fujino
Journal:  J Anesth       Date:  2017-12-06       Impact factor: 2.078

3.  Comparison between the SAPIEN S3 and the SAPIEN XT transcatheter heart valves: A single-center experience.

Authors:  Fadi J Sawaya; Marco Spaziano; Thierry Lefèvre; Andrew Roy; Phillippe Garot; Thomas Hovasse; Antoinette Neylon; Hakim Benamer; Mauro Romano; Thierry Unterseeh; Marie-Claude Morice; Bernard Chevalier
Journal:  World J Cardiol       Date:  2016-12-26

4.  Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre-Existent Right Bundle Branch Block.

Authors:  Lennart van Gils; Didier Tchetche; Thibault Lhermusier; Masieh Abawi; Nicolas Dumonteil; Ramón Rodriguez Olivares; Javier Molina-Martin de Nicolas; Pieter R Stella; Didier Carrié; Peter P De Jaegere; Nicolas M Van Mieghem
Journal:  J Am Heart Assoc       Date:  2017-03-03       Impact factor: 5.501

5.  Trends in patient characteristics and clinical outcome over 8 years of transcatheter aortic valve implantation.

Authors:  F van Kesteren; M S van Mourik; E M A Wiegerinck; J Vendrik; J J Piek; J G Tijssen; K T Koch; J P S Henriques; J J Wykrzykowska; R J de Winter; A H G Driessen; A Kaya; R N Planken; M M Vis; J Baan
Journal:  Neth Heart J       Date:  2018-09       Impact factor: 2.380

Review 6.  Spotlight on the SAPIEN 3 transcatheter heart valve.

Authors:  Tobias Rheude; Johannes Blumenstein; Helge Möllmann; Oliver Husser
Journal:  Med Devices (Auckl)       Date:  2018-10-01

Review 7.  Rate and Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation: Current Status.

Authors:  Eleonora Russo; Domenico R Potenza; Michela Casella; Raimondo Massaro; Giulio Russo; Maurizio Braccio; Antonio Dello Russo; Mauro Cassese
Journal:  Curr Cardiol Rev       Date:  2019

8.  International Expert Consensus on Sutureless and Rapid Deployment Valves in Aortic Valve Replacement Using Minimally Invasive Approaches.

Authors:  Mattia Glauber; Simon C Moten; Eugenio Quaini; Marco Solinas; Thierry A Folliguet; Bart Meuris; Antonio Miceli; Peter J Oberwalder; Manfredo Rambaldini; Kevin H T Teoh; Gopal Bhatnagar; Michael A Borger; Denis Bouchard; Olivier Bouchot; Stephen C Clark; Otto E Dapunt; Matteo Ferrarini; Theodor J M Fischlein; Guenther Laufer; Carmelo Mignosa; Russell Millner; Philippe Noirhomme; Steffen Pfeiffer; Xavier Ruyra-Baliarda; Malakh Lal Shrestha; Rakesh M Suri; Giovanni Troise; Borut Gersak
Journal:  Innovations (Phila)       Date:  2016 May-Jun

9.  Rationale and design of the Edwards SAPIEN-3 periprosthetic leakage evaluation versus Medtronic CoreValve in transfemoral aortic valve implantation (ELECT) trial : A randomised comparison of balloon-expandable versus self-expanding transcatheter aortic valve prostheses.

Authors:  M Abawi; P Agostoni; N H M Kooistra; M Samim; F Nijhoff; M Voskuil; H Nathoe; P A Doevendans; S A Chamuleau; K Urgel; J Hendrikse; T Leiner; A C Abrahams; B van der Worp; P R Stella
Journal:  Neth Heart J       Date:  2017-05       Impact factor: 2.380

10.  Evolution of transcatheter aortic valve implantation over 7 years: results of a prospective single-centre registry of 2000 patients in a large municipal hospital (TAVIK Registry).

Authors:  Gerhard Schymik; Valentin Herzberger; Jens Bergmann; Peter Bramlage; Lars O Conzelmann; Alexander Würth; Armin Luik; Holger Schröfel; Panagiotis Tzamalis
Journal:  BMJ Open       Date:  2018-10-25       Impact factor: 2.692

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.