Literature DB >> 26032159

Percutaneous closure of patent ductus arteriosus in children using amplatzer duct occluder II: relationship between PDA type and risk of device protrusion into the descending aorta.

Samer Masri1, Issam El Rassi2, Mariam Arabi1, Anas Tabbakh1, Fadi Bitar1.   

Abstract

OBJECTIVES: To compare the efficacy and safety of Amplatzer Duct Occluder II (ADOII) among the various patent ductus arteriosus (PDA) types, and to assess the association between development of aortic obstruction and the PDA type in terms of measurable parameters as the device angulation and distance of upper end protrusion into the aortic lumen.
METHODS: Retrospective cohort study involving 50 consecutive subjects who underwent ADO II device closure of PDA.
RESULTS: The median age and weight at intervention were 13 months (5.5 months to 18 years) and 11 (6-67) kg respectively. The median smallest ductal diameter by angiography was 3.2 (1.9-5.4) mm. Thirty two patients had type A PDA, 5 had type C, 5 had type D, and 8 had type E. Residual shunt was seen in only 1 patient who had a tubular PDA and resolved within 2 months of the procedure. No device embolization or pulmonary side protrusion were noted. There was a 16% aortic protrusion rate. The median distance of protrusion of the upper end of the device into the aortic lumen was 3.1 (0-9) mm and the median angle formed between the aortic end of the device and the PDA take-off was 10.4 (0-80.6) degrees. These latter parameters of aortic obstruction were significantly higher in the non-conical PDA group as compared to the conical PDA. Nevertheless, there was no significant coarctation due to aortic retention disc protrusion.
CONCLUSION: Device closure of PDA using the ADO II is a safe procedure for chosen types of PDA. We demonstrated a novel technique for objective assessment of device protrusion into the descending aorta based on measurable parameters. ADOII device closure of non-conical PDAs warrants closer follow ups.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  closure PDA; congenital heart disease; interventional devices; pediatric intervention

Mesh:

Year:  2015        PMID: 26032159     DOI: 10.1002/ccd.25940

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  7 in total

1.  New Nano-Film Single-Rivet Patent Ductus Arteriosus Occluders: A Prospective, Randomized and Double-blind Study.

Authors:  Xiao-Ke Shang; Mei Liu; Hong-Jun Li; Rong Lu; Shan-Shan Ding; Bin Wang; Nian-Guo Dong; Shu Chen
Journal:  Curr Med Sci       Date:  2018-03-15

2.  Percutaneous Patent Ductus Arteriosus (PDA) Closure in Very Preterm Infants: Feasibility and Complications.

Authors:  Carl H Backes; Sharon L Cheatham; Grace M Deyo; Scott Leopold; Molly K Ball; Charles V Smith; Vidu Garg; Ralf J Holzer; John P Cheatham; Darren P Berman
Journal:  J Am Heart Assoc       Date:  2016-02-12       Impact factor: 5.501

3.  Iatrogenic obstruction of the aorta - a sequence of delayed, fatal complications after 'off-label' interventional persistent ductus arteriosus closure.

Authors:  Ireneusz Haponiuk; Konrad Paczkowski; Maciej Chojnicki; Radosław Jaworski
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2016-02-01       Impact factor: 1.195

4.  Characteristics of Patent Ductus Arteriosus in Congenital Rubella Syndrome.

Authors:  Michiko Toizumi; Cam Giang T Do; Hideki Motomura; Tin N Do; Hirofumi Fukunaga; Makiko Iijima; Nhan Nt Le; Hung Thanh Nguyen; Hiroyuki Moriuchi; Lay-Myint Yoshida
Journal:  Sci Rep       Date:  2019-11-19       Impact factor: 4.379

5.  Transcatheter Closure of Patent Ductus Arteriosus via Different Approaches.

Authors:  Zeming Zhou; Yuanrui Gu; Hong Zheng; Shiguo Li; Liang Xu; Qiong Liu; Junyi Wan; Jianhua Lv; Huijun Song; Chaowu Yan; Haibo Hu; Gejun Zhang; Zhongying Xu; Jinglin Jin
Journal:  Front Cardiovasc Med       Date:  2022-01-10

Review 6.  Consensus Guidelines for the Prevention and Management of Periprocedural Complications of Transcatheter Patent Ductus Arteriosus Closure with the Amplatzer Piccolo Occluder in Extremely Low Birth Weight Infants.

Authors:  Shyam Sathanandam; Dan Gutfinger; Brian Morray; Darren Berman; Matthew Gillespie; Thomas Forbes; Jason N Johnson; Ruchira Garg; Sophie Malekzadeh-Milani; Alain Fraisse; Osman Baspinar; Evan M Zahn
Journal:  Pediatr Cardiol       Date:  2021-06-30       Impact factor: 1.655

7.  Cost-effectiveness analysis of different devices used for the closure of small-to-medium-sized patent ductus arteriosus in pediatric patients.

Authors:  Sonia A El-Saiedi; Amal M El Sisi; Rodina Sobhy Mandour; Doaa M Abdel-Aziz; Wael A Attia
Journal:  Ann Pediatr Cardiol       Date:  2017 May-Aug
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.