Abstract

Surface changes and wear resistance were investigated on eight different dental materials, using a laser reflexion technique and a profilometer. The tested materials were: (table; see text) The materials were subjected to brushing in a brushing machine, containing a toothpaste-water slurry. Two different toothpastes were used separately; Clinomyn and Colgate. The results showed that all the materials were to some extent affected by the brushing. Titanium was the most and SR Isosit N the least wear resistant material. Clinomyn and Colgate influenced the materials in different ways depending on their abrasive properties.