Seven Q-Tracks monitors of laboratory quality drive general performance improvement: experience from the College of American Pathologists Q-Tracks program 1999-2011.

Frederick A Meier1, Rhona J Souers, Peter J Howanitz, Joseph A Tworek, Peter L Perrotta, Raouf E Nakhleh, Donald S Karcher, Christine Bashleben, Teresa P Darcy, Ron B Schifman, Bruce A Jones.   

Abstract

CONTEXT: Many production systems employ standardized statistical monitors that measure defect rates and cycle times, as indices of performance quality. Clinical laboratory testing, a system that produces test results, is amenable to such monitoring.
OBJECTIVE: To demonstrate patterns in clinical laboratory testing defect rates and cycle time using 7 College of American Pathologists Q-Tracks program monitors.
DESIGN: Subscribers measured monthly rates of outpatient order-entry errors, identification band defects, and specimen rejections; median troponin order-to-report cycle times and rates of STAT test receipt-to-report turnaround time outliers; and critical values reporting event defects, and corrected reports. From these submissions Q-Tracks program staff produced quarterly and annual reports. These charted each subscriber's performance relative to other participating laboratories and aggregate and subgroup performance over time, dividing participants into best and median performers and performers with the most room to improve. Each monitor's patterns of change present percentile distributions of subscribers' performance in relation to monitoring durations and numbers of participating subscribers. Changes over time in defect frequencies and the cycle duration quantify effects on performance of monitor participation.
RESULTS: All monitors showed significant decreases in defect rates as the 7 monitors ran variously for 6, 6, 7, 11, 12, 13, and 13 years. The most striking decreases occurred among performers who initially had the most room to improve and among subscribers who participated the longest. All 7 monitors registered significant improvement. Participation effects improved between 0.85% and 5.1% per quarter of participation.
CONCLUSIONS: Using statistical quality measures, collecting data monthly, and receiving reports quarterly and yearly, subscribers to a comparative monitoring program documented significant decreases in defect rates and shortening of a cycle time for 6 to 13 years in all 7 ongoing clinical laboratory quality monitors.

Entities:  

Mesh:

Year:  2015        PMID: 26030245     DOI: 10.5858/arpa.2014-0090-CP

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  2 in total

1.  Benchmarking diagnostic laboratory performance: Survey results for Germany, Austria, and Switzerland.

Authors:  Wolfgang Huf; Mike Mohns; Tetiana Garmatiuk; Rebecca Lister; Christoph Buchta; Brigitte Ettl; Ursula Köller
Journal:  Wien Klin Wochenschr       Date:  2021-10-28       Impact factor: 2.275

2.  Changes in error rates in the Australian key incident monitoring and management system program.

Authors:  Stephanie Gay; Tony Badrick
Journal:  Biochem Med (Zagreb)       Date:  2020-04-15       Impact factor: 2.313

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.