Literature DB >> 26030088

Comparison of Single-Point and Continuous Sampling Methods for Estimating Residential Indoor Temperature and Humidity.

James D Johnston1, Brianna M Magnusson1, Dennis Eggett2, Scott C Collingwood3, Scott A Bernhardt4.   

Abstract

Residential temperature and humidity are associated with multiple health effects. Studies commonly use single-point measures to estimate indoor temperature and humidity exposures, but there is little evidence to support this sampling strategy. This study evaluated the relationship between single-point and continuous monitoring of air temperature, apparent temperature, relative humidity, and absolute humidity over four exposure intervals (5-min, 30-min, 24-hr, and 12-days) in 9 northern Utah homes, from March-June 2012. Three homes were sampled twice, for a total of 12 observation periods. Continuous data-logged sampling was conducted in homes for 2-3 wks, and simultaneous single-point measures (n = 114) were collected using handheld thermo-hygrometers. Time-centered single-point measures were moderately correlated with short-term (30-min) data logger mean air temperature (r = 0.76, β = 0.74), apparent temperature (r = 0.79, β = 0.79), relative humidity (r = 0.70, β = 0.63), and absolute humidity (r = 0.80, β = 0.80). Data logger 12-day means were also moderately correlated with single-point air temperature (r = 0.64, β = 0.43) and apparent temperature (r = 0.64, β = 0.44), but were weakly correlated with single-point relative humidity (r = 0.53, β = 0.35) and absolute humidity (r = 0.52, β = 0.39). Of the single-point RH measures, 59 (51.8%) deviated more than ±5%, 21 (18.4%) deviated more than ±10%, and 6 (5.3%) deviated more than ±15% from data logger 12-day means. Where continuous indoor monitoring is not feasible, single-point sampling strategies should include multiple measures collected at prescribed time points based on local conditions.

Entities:  

Keywords:  exposure misclassification; humidity; indoor; monitoring; temperature; thermo-hygrometer

Mesh:

Year:  2015        PMID: 26030088      PMCID: PMC4712705          DOI: 10.1080/15459624.2015.1047024

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  22 in total

1.  The relationship between moisture or mould observations in houses and the state of health of their occupants.

Authors:  O M Koskinen; T M Husman; T M Meklin; A I Nevalainen
Journal:  Eur Respir J       Date:  1999-12       Impact factor: 16.671

Review 2.  Housing and health: time again for public health action.

Authors:  James Krieger; Donna L Higgins
Journal:  Am J Public Health       Date:  2002-05       Impact factor: 9.308

3.  Prevalence and incidence of respiratory symptoms in relation to indoor dampness: the RHINE study.

Authors:  M I Gunnbjörnsdóttir; K A Franklin; D Norbäck; E Björnsson; D Gislason; E Lindberg; C Svanes; E Omenaas; E Norrman; R Jõgi; E J Jensen; A Dahlman-Höglund; C Janson
Journal:  Thorax       Date:  2006-01-05       Impact factor: 9.139

4.  Prevalence of indoor allergen exposures among New Orleans children with asthma.

Authors:  Felicia A Rabito; Shahed Iqbal; Elizabeth Holt; L Faye Grimsley; Tareq M S Islam; Susanne K Scott
Journal:  J Urban Health       Date:  2007-11       Impact factor: 3.671

5.  The impact of excess heat events in Maricopa County, Arizona: 2000--2005.

Authors:  Fuyuen Y Yip; W Dana Flanders; Amy Wolkin; David Engelthaler; William Humble; Antonio Neri; Lauren Lewis; Lorraine Backer; Carol Rubin
Journal:  Int J Biometeorol       Date:  2008-07-08       Impact factor: 3.787

6.  Classroom aeroallergen exposure in Arkansas head start centers.

Authors:  Tamara T Perry; Perla A Vargas; Jeremy Bufford; Charles Feild; Michael Flick; Pippa M Simpson; Robert G Hamilton; Stacie M Jones
Journal:  Ann Allergy Asthma Immunol       Date:  2008-04       Impact factor: 6.347

7.  Mold damage in homes and wheezing in infants.

Authors:  Seung-Hyun Cho; Tiina Reponen; Grace LeMasters; Linda Levin; Jian Huang; Teija Meklin; Patrick Ryan; Manuel Villareal; David Bernstein
Journal:  Ann Allergy Asthma Immunol       Date:  2006-10       Impact factor: 6.347

8.  Population dynamics of the house dust mites Dermatophagoides farinae, D. pteronyssinus, and Euroglyphus maynei (Acari: Pyroglyphidae) at specific relative humidities.

Authors:  L G Arlian; P D Confer; C M Rapp; D L Vyszenski-Moher; J C Chang
Journal:  J Med Entomol       Date:  1998-01       Impact factor: 2.278

9.  Problems with damp and cold housing among Pacific families in New Zealand.

Authors:  Sarnia Butler; Maynard Williams; Colin Tukuitonga; Janis Paterson
Journal:  N Z Med J       Date:  2003-07-11

10.  Feasibility of using subject-collected dust samples in epidemiologic and clinical studies of indoor allergens.

Authors:  Samuel J Arbes; Michelle Sever; Ben Vaughn; Jigna Mehta; Jeffrey T Lynch; Herman Mitchell; Jane A Hoppin; Harvey L Spencer; Dale P Sandler; Darryl C Zeldin
Journal:  Environ Health Perspect       Date:  2005-06       Impact factor: 9.031

View more
  2 in total

Review 1.  Moisture parameters and fungal communities associated with gypsum drywall in buildings.

Authors:  Sandra Dedesko; Jeffrey A Siegel
Journal:  Microbiome       Date:  2015-12-08       Impact factor: 14.650

2.  Evaporative Cooler Use Influences Temporal Indoor Relative Humidity but Not Dust Mite Allergen Levels in Homes in a Semi-Arid Climate.

Authors:  James D Johnston; Steven C Tuttle; Morgan C Nelson; Rebecca K Bradshaw; Taylor G Hoybjerg; Julene B Johnson; Bryce A Kruman; Taylor S Orton; Ryan B Cook; Dennis L Eggett; K Scott Weber
Journal:  PLoS One       Date:  2016-01-25       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.