Literature DB >> 26025297

[Fiberless miniature chandelier LED endoilluminator for pars plana vitrectomy].

P S Kölbl1, C Lindner2, C Lingenfelder2, S Deuchler3, P Singh3, F H J Koch3, M Heßling4.   

Abstract

BACKGROUND: Currently available chandelier endoilluminators for pars plana vitrectomy consist of conventional optical fibers coupled to a light source. The light probes of these fibers now provide wide emittance angles but it is still often not possible to illuminate the whole intraocular space via just one incision. Therefore, several light probes or additional handheld endoilluminators have to be used simultaneously or the lights have to be repositioned during surgery.
OBJECTIVE: The presented prototype of a fiberless chandelier light-emitting diode (LED) endoilluminator aims at illuminating the whole intraocular space with just one incision while reducing the risk of harming the retina.
MATERIAL AND METHODS: The light source is a white LED with a conical tip that allows stable fixation within an incision. The physical properties of these LEDs were determined and used for calculating the relevant irradiance to assess the risk of causing harm to the eye. The illumination of the intraocular space was investigated using porcine eyes.
RESULTS: The illumination of porcine eyes with the modified LEDs was bright and homogeneous. Measurements and subsequent calculations proved that the expected thermal load and photochemical hazard were very low for human eyes.
CONCLUSION: The hitherto existing experimental results on porcine eyes and the theoretical considerations on human eyes were found to be positive; therefore, it is expected that this new fiberless chandelier LED endoilluminator will prove to be advantageous for human patients. It promises a reduced number of incisions with a simplified handling and need to add handheld light sources only if minimal intensity oblique illumination is helpful together with the chandelier illumination. This contributes to a significant reduction of phototoxicity risks and additionally there is a chance for a cost reduction because expensive xenon or mercury lamps are no longer necessary. These expectations have to be verified by further studies on human eyes.

Entities:  

Keywords:  Light conductor; Light probe; Phototoxicity; Porcine eyes; Retina

Mesh:

Year:  2016        PMID: 26025297     DOI: 10.1007/s00347-015-0050-6

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  8 in total

1.  A new wide-angle endoillumination probe for use during vitrectomy.

Authors:  Gholam A Peyman; Christina Canakis; Charalampos Livir-Rallatos; James Easley
Journal:  Retina       Date:  2002-04       Impact factor: 4.256

2.  Optical properties of human sclera, and their consequences for transscleral laser applications.

Authors:  A Vogel; C Dlugos; R Nuffer; R Birngruber
Journal:  Lasers Surg Med       Date:  1991       Impact factor: 4.025

Review 3.  [Exposure to light during vitreoretinal surgery. II: Characteristics of endoilluminators].

Authors:  T Ach; A E Höh; R Amberger; S Dithmar
Journal:  Ophthalmologe       Date:  2008-10       Impact factor: 1.059

4.  Two shielded 'bullet' probes for panoramic endoillumination.

Authors:  E H Ryan
Journal:  Arch Ophthalmol       Date:  1997-01

5.  Vitrectomy: a pars plana approach.

Authors:  R Machemer; H Buettner; E W Norton; J M Parel
Journal:  Trans Am Acad Ophthalmol Otolaryngol       Date:  1971 Jul-Aug

6.  The retinal irradiance and spectral properties of the multiport illumination system for vitreous surgery.

Authors:  F H Koch; H P Schmidt; T Mönks; S H Blumenröder; A Haller; R L Steinmetz
Journal:  Am J Ophthalmol       Date:  1993-10-15       Impact factor: 5.258

7.  Light-emitting diode technology in vitreoretinal surgery.

Authors:  Stefan Dithmar; Alexandra E Hoeh; Roman Amberger; Mira Ruppenstein; Thomas Ach
Journal:  Retina       Date:  2011-05       Impact factor: 4.256

8.  Guidelines on limits of exposure to broad-band incoherent optical radiation (0.38 to 3 microM). International Commission on Non-Ionizing Radiation Protection.

Authors: 
Journal:  Health Phys       Date:  1997-09       Impact factor: 1.316

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.