Literature DB >> 26024275

Evaluation of water quality functions of conventional and advanced soil-based onsite wastewater treatment systems.

Jennifer A Cooper, George W Loomis, David V Kalen, Jose A Amador.   

Abstract

Shallow narrow drainfields are assumed to provide better wastewater renovation than conventional drainfields and are used for protection of surface and ground water. To test this assumption, we evaluated the water quality functions of two advanced onsite wastewater treatment system (OWTS) drainfields-shallow narrow (SND) and Geomat (GEO)-and a conventional pipe and stone (P&S) drainfield over 12 mo using replicated ( = 3) intact soil mesocosms. The SND and GEO mesocosms received effluent from a single-pass sand filter, whereas the P&S received septic tank effluent. Between 97.1 and 100% of 5-d biochemical oxygen demand (BOD), fecal coliform bacteria, and total phosphorus (P) were removed in all drainfield types. Total nitrogen (N) removal averaged 12.0% for P&S, 4.8% for SND, and 5.4% for GEO. A mass balance analysis accounted for 95.1% (SND), 94.1% (GEO), and 87.6% (P&S) of N inputs. When the whole treatment train (excluding the septic tank) is considered, advanced systems, including sand filter pretreatment and SND or GEO soil-based treatment, removed 99.8 to 99.9% of BOD, 100% of fecal coliform bacteria and P, and 26.0 to 27.0% of N. In contrast, the conventional system removed 99.4% of BOD and 100% of fecal coliform bacteria and P but only 12.0% of N. All drainfield types performed similarly for most water quality functions despite differences in placement within the soil profile. However, inclusion of the pretreatment step in advanced system treatment trains results in better N removal than in conventional treatment systems despite higher drainfield N removal rates in the latter.
Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

Entities:  

Year:  2015        PMID: 26024275     DOI: 10.2134/jeq2014.06.0277

Source DB:  PubMed          Journal:  J Environ Qual        ISSN: 0047-2425            Impact factor:   2.751


  2 in total

1.  Modeling Nitrogen Losses in Conventional and Advanced Soil-Based Onsite Wastewater Treatment Systems under Current and Changing Climate Conditions.

Authors:  Ivan Morales; Jennifer Cooper; José A Amador; Thomas B Boving
Journal:  PLoS One       Date:  2016-06-29       Impact factor: 3.240

2.  Hell and High Water: Diminished Septic System Performance in Coastal Regions Due to Climate Change.

Authors:  Jennifer A Cooper; George W Loomis; Jose A Amador
Journal:  PLoS One       Date:  2016-09-01       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.