Abstract

The Boston type 1 keratoprosthesis (KPro) is the most commonly used artificial cornea worldwide. Long-term bandage contact lenses are the standard of care for patients with these devices. The goal of bandage contact lenses is to maintain hydration and to protect the corneal tissue that surrounds the anterior plate of the keratoprosthesis which is vulnerable to desiccation, epithelial breakdown, dellen formation, and corneal melt. Contact lenses can also improve comfort, correct refractive errors, and improve the cosmesis of patients with artificial corneas. However, the continuous use of contact lenses places these patients at risk for complications such as lens loss, lens deposits, chronic conjunctivitis, and infection. In addition, obtaining an adequate fit in a patient with a compromised ocular surface and history of multiple surgeries including glaucoma drainage devices can present a challenge. This review discusses the types of contact lenses used, special fitting considerations, and common complications in patients with previous KPro surgery.

Entities:  

Mesh:

Year:  2015        PMID: 26020487     DOI: 10.1097/ICL.0000000000000154

Source DB:  PubMed          Journal:  Eye Contact Lens        ISSN: 1542-2321            Impact factor:   2.018


  5 in total

1.  [Boston-keratoprosthesis : Preliminary experiences in 13 high-risk eyes from the Department of Ophthalmology of the University of Cologne].

Authors:  F Schaub; D Hos; F Bucher; S Siebelmann; B O Bachmann; C Cursiefen
Journal:  Ophthalmologe       Date:  2016-06       Impact factor: 1.059

2.  [Boston keratoprosthesis: 73 eyes from Germany : An overview of experiences from two centers].

Authors:  F Schaub; I Neuhann; P Enders; B O Bachmann; B Koller; T Neuhann; C Cursiefen
Journal:  Ophthalmologe       Date:  2018-09       Impact factor: 1.059

3.  Corneal graft dellen in a patient implanted with a Boston keratoprosthesis type 1.

Authors:  Riccardo Scotto; Aldo Vagge; Carlo E Traverso
Journal:  Int Ophthalmol       Date:  2016-04-11       Impact factor: 2.031

4.  Resolution of an exposed pars plana Baerveldt shunt in a patient with a Boston keratoprosthesis type 1 without surgery.

Authors:  Daniel J Oh; Raman Michael; Thasarat Vajaranant; M Soledad Cortina; Ellen Shorter
Journal:  Ther Adv Ophthalmol       Date:  2019-08-12

Review 5.  Boston type 1 keratoprosthesis from patient selection through postoperative management: a review for the keratoprosthetic surgeon.

Authors:  Samantha L Williamson; M Soledad Cortina
Journal:  Clin Ophthalmol       Date:  2016-03-14
  5 in total