MR-Guided Near-Infrared Spectral Tomography Increases Diagnostic Performance of Breast MRI.

Michael A Mastanduno1, Junqing Xu2, Fadi El-Ghussein1, Shudong Jiang1, Hong Yin3, Yan Zhao1, Ke Wang2, Fang Ren2, Jiang Gui4, Brian W Pogue1, Keith D Paulsen5.   

Abstract

PURPOSE: The purpose of this study was to determine the diagnostically most important molecular biomarkers quantified by magnetic resonance-guided (MR) near-infrared spectral tomography (NIRST) that distinguish malignant breast lesions from benign abnormalities when combined with outcomes from clinical breast MRI. EXPERIMENTAL
DESIGN: The study was HIPAA compliant and approved by the Dartmouth Institutional Review Board, the NIH, the United States State Department, and Xijing Hospital. MR-guided NIRST evaluated hemoglobin, water, and lipid content in regions of interest defined by concurrent dynamic contrast-enhanced MRI (DCE-MRI) in the breast. MRI plus NIRST was performed in 44 subjects (median age, 46, age range, 20-81 years), 28 of whom had subsequent malignant pathologic diagnoses, and 16 had benign conditions. A subset of 30 subject examinations yielded optical data that met minimum sensitivity requirements to the suspicious lesion and were included in the analyses of diagnostic performance.
RESULTS: In the subset of 30 subject examinations meeting minimum optical data sensitivity criterion, the MR-guided NIRST separated malignant from benign lesions using total hemoglobin (HbT; P < 0.01) and tissue optical index (TOI; P < 0.001). Combined MRI plus TOI data caused one false positive and 1 false negative, and produced the best diagnostic performance, yielding an AUC of 0.95, sensitivity of 95%, specificity of 89%, positive predictive value of 95%, and negative predictive value of 89%, respectively.
CONCLUSIONS: MRI plus NIRST results correlated well with histopathologic diagnoses and could provide additional information to reduce the number of MRI-directed biopsies. ©2015 American Association for Cancer Research.

Entities:  

Mesh:

Year:  2015        PMID: 26019171      PMCID: PMC4763338          DOI: 10.1158/1078-0432.CCR-14-2546

Source DB:  PubMed          Journal:  Clin Cancer Res        ISSN: 1078-0432            Impact factor:   12.531


  29 in total

1.  Dynamic breast MR imaging: are signal intensity time course data useful for differential diagnosis of enhancing lesions?

Authors:  C K Kuhl; P Mielcareck; S Klaschik; C Leutner; E Wardelmann; J Gieseke; H H Schild
Journal:  Radiology       Date:  1999-04       Impact factor: 11.105

2.  Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement.

Authors:  V Ntziachristos; A G Yodh; M Schnall; B Chance
Journal:  Proc Natl Acad Sci U S A       Date:  2000-03-14       Impact factor: 11.205

3.  Imaging breast adipose and fibroglandular tissue molecular signatures by using hybrid MRI-guided near-infrared spectral tomography.

Authors:  Ben Brooksby; Brian W Pogue; Shudong Jiang; Hamid Dehghani; Subhadra Srinivasan; Christine Kogel; Tor D Tosteson; John Weaver; Steven P Poplack; Keith D Paulsen
Journal:  Proc Natl Acad Sci U S A       Date:  2006-05-26       Impact factor: 11.205

4.  Sensitivity of MRI-guided near-infrared spectroscopy clinical breast exam data and its impact on diagnostic performance.

Authors:  Michael A Mastanduno; Junqing Xu; Fadi El-Ghussein; Shudong Jiang; Hong Yin; Yan Zhao; Kelly E Michaelsen; Ke Wang; Fang Ren; Brian W Pogue; Keith D Paulsen
Journal:  Biomed Opt Express       Date:  2014-08-22       Impact factor: 3.732

5.  Remote positioning optical breast magnetic resonance coil for slice-selection during image-guided near-infrared spectroscopy of breast cancer.

Authors:  Michael A Mastanduno; Shudong Jiang; Roberta DiFlorio-Alexander; Brian W Pogue; Keith D Paulsen
Journal:  J Biomed Opt       Date:  2011-06       Impact factor: 3.170

6.  Early-stage invasive breast cancers: potential role of optical tomography with US localization in assisting diagnosis.

Authors:  Quing Zhu; Poornima U Hegde; Andrew Ricci; Mark Kane; Edward B Cronin; Yasaman Ardeshirpour; Chen Xu; Andres Aguirre; Scott H Kurtzman; Peter J Deckers; Susan H Tannenbaum
Journal:  Radiology       Date:  2010-06-22       Impact factor: 11.105

7.  In vivo absorption, scattering, and physiologic properties of 58 malignant breast tumors determined by broadband diffuse optical spectroscopy.

Authors:  Albert Cerussi; Natasha Shah; David Hsiang; Amanda Durkin; John Butler; Bruce J Tromberg
Journal:  J Biomed Opt       Date:  2006 Jul-Aug       Impact factor: 3.170

8.  Breast cancer detection based on incremental biochemical and physiological properties of breast cancers: a six-year, two-site study.

Authors:  Britton Chance; Shoko Nioka; Jun Zhang; Emily F Conant; Emily Hwang; Susanne Briest; Susan G Orel; Mitchell D Schnall; Brian J Czerniecki
Journal:  Acad Radiol       Date:  2005-08       Impact factor: 3.173

9.  Adaptable near-infrared spectroscopy fiber array for improved coupling to different breast sizes during clinical MRI.

Authors:  Michael A Mastanduno; Fadi El-Ghussein; Shudong Jiang; Roberta Diflorio-Alexander; Xu Junqing; Yin Hong; Brian W Pogue; Keith D Paulsen
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

10.  Characterization of metabolic differences between benign and malignant tumors: high-spectral-resolution diffuse optical spectroscopy.

Authors:  Shwayta Kukreti; Albert E Cerussi; Wendy Tanamai; David Hsiang; Bruce J Tromberg; Enrico Gratton
Journal:  Radiology       Date:  2010-01       Impact factor: 11.105

View more
  13 in total

1.  Quantitative photoacoustic image reconstruction improves accuracy in deep tissue structures.

Authors:  Michael A Mastanduno; Sanjiv S Gambhir
Journal:  Biomed Opt Express       Date:  2016-09-01       Impact factor: 3.732

Review 2.  A review of optical breast imaging: Multi-modality systems for breast cancer diagnosis.

Authors:  Quing Zhu; Steven Poplack
Journal:  Eur J Radiol       Date:  2020-05-18       Impact factor: 3.528

3.  Portable, parallel 9-wavelength near-infrared spectral tomography (NIRST) system for efficient characterization of breast cancer within the clinical oncology infusion suite.

Authors:  Yan Zhao; Brian W Pogue; Steffen J Haider; Jiang Gui; Roberta M diFlorio-Alexander; Keith D Paulsen; Shudong Jiang
Journal:  Biomed Opt Express       Date:  2016-05-16       Impact factor: 3.732

4.  Multiobjective guided priors improve the accuracy of near-infrared spectral tomography for breast imaging.

Authors:  Jinchao Feng; Shudong Jiang; Junqing Xu; Yan Zhao; Brian W Pogue; Keith D Paulsen
Journal:  J Biomed Opt       Date:  2016-09-01       Impact factor: 3.170

5.  Performance assessment of MRI guided continuous wave near-infrared spectral tomography for breast imaging.

Authors:  Jinchao Feng; Shudong Jiang; Brian W Pogue; Keith D Paulsen
Journal:  Biomed Opt Express       Date:  2021-11-18       Impact factor: 3.732

6.  2.5 Hz sample rate time-domain near-infrared optical tomography based on SPAD-camera image tissue hemodynamics.

Authors:  Jingjing Jiang; Aldo Di Costanzo Mata; Scott Lindner; Edoardo Charbon; Martin Wolf; Alexander Kalyanov
Journal:  Biomed Opt Express       Date:  2021-12-07       Impact factor: 3.732

7.  Prospective assessment of adjunctive ultrasound-guided diffuse optical tomography in women undergoing breast biopsy: Impact on BI-RADS assessments.

Authors:  Steven P Poplack; Catherine A Young; Ian S Hagemann; Jingqin Luo; Cheryl R Herman; Kimberly Wiele; Shuying Li; Yifeng Zeng; Matthew F Covington; Quing Zhu
Journal:  Eur J Radiol       Date:  2021-11-13       Impact factor: 4.531

8.  Direct Regularization From Co-Registered Contrast MRI Improves Image Quality of MRI-Guided Near-Infrared Spectral Tomography of Breast Lesions.

Authors:  Limin Zhang; Shudong Jiang; Yan Zhao; Jinchao Feng; Brian W Pogue; Keith D Paulsen
Journal:  IEEE Trans Med Imaging       Date:  2018-05       Impact factor: 10.048

9.  Weighting function effects in a direct regularization method for image-guided near-infrared spectral tomography of breast cancer.

Authors:  Jinchao Feng; Shudong Jiang; Brian W Pogue; Keith Paulsen
Journal:  Biomed Opt Express       Date:  2018-06-25       Impact factor: 3.732

10.  Addition of T2-guided optical tomography improves noncontrast breast magnetic resonance imaging diagnosis.

Authors:  Jinchao Feng; Junqing Xu; Shudong Jiang; Hong Yin; Yan Zhao; Jiang Gui; Ke Wang; Xiuhua Lv; Fang Ren; Brian W Pogue; Keith D Paulsen
Journal:  Breast Cancer Res       Date:  2017-10-24       Impact factor: 6.466

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.