Changes in irradiance and energy density in relation to different curing distances.

Rafael Silva Beolchi1, Cacio Moura-Netto2, Renato Miotto Palo3, Carlos Rocha Gomes Torres1, Bruno Pelissier4.   

Abstract

The present study aimed to assess the influence of curing distance on the loss of irradiance and power density of four curing light devices. The behavior in terms of power density of four different dental curing devices was analyzed (Valo, Elipar 2, Radii-Cal, and Optilux-401) using three different distances of photopolymerization (0 mm, 4 mm, and 8 mm). All devices had their power density measured using a MARC simulator. Ten measurements were made per device at each distance. The total amount of energy delivered and the required curing time to achieve 16 J/cm(2) of energy was also calculated. Data were statistically analyzed with one-way analysis of variance and Tukey's tests (p < 0.05). The curing distance significantly interfered with the loss of power density for all curing light devices, with the farthest distance generating the lowest power density and consequently the longer time to achieve an energy density of 16 J/cm(2) (p < 0.01). Comparison of devices showed that Valo, in extra power mode, showed the best results at all distances, followed by Valo in high power mode, Valo in standard mode, Elipar 2, Radii-Cal, and Optilux-401 halogen lamp (p < 0.01). These findings indicate that all curing lights induced a significant loss of irradiance and total energy when the light was emitted farther from the probe. The Valo device in extra power mode showed the highest power density and the shortest time to achieve an energy density of 16 J/cm(2) at all curing distances.

Mesh:

Substances:

Year:  2015        PMID: 26017490     DOI: 10.1590/1807-3107BOR-2015.vol29.0060

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  6 in total

1.  A new arginine-based dental adhesive system: formulation, mechanical and anti-caries properties.

Authors:  Saulo Geraldeli; Eveline F Soares; Andres J Alvarez; Tanaz Farivar; Robert C Shields; Mario A C Sinhoreti; Marcelle M Nascimento
Journal:  J Dent       Date:  2017-06-03       Impact factor: 4.379

2.  Structural and mechanical properties of a giomer-based bulk fill restorative in different curing conditions.

Authors:  Mustafa Sarp Kaya; Meltem Bakkal; Ali Durmus; Zehra Durmus
Journal:  J Appl Oral Sci       Date:  2018-01-18       Impact factor: 2.698

Review 3.  Factors affecting polymerization of resin-based composites: A literature review.

Authors:  Maan M AlShaafi
Journal:  Saudi Dent J       Date:  2017-03-07

4.  Knowledge and Attitude of Dental Clinicians towards Light-Curing Units: A Cross-Sectional Study.

Authors:  Dana Al-Senan; Fatin Ageel; Amani Aldosari; Haifa Maktabi
Journal:  Int J Dent       Date:  2021-06-14

5.  Transmission of Curing Light through Moist, Air-Dried, and EDTA Treated Dentine and Enamel.

Authors:  E Uusitalo; J Varrela; L Lassila; P K Vallittu
Journal:  Biomed Res Int       Date:  2016-06-30       Impact factor: 3.411

6.  Infection Control Barrier and Curing Time as Factors Affecting the Irradiance of Light-Cure Units.

Authors:  Reem A Ajaj; Hani M Nassar; Fatin A Hasanain
Journal:  J Int Soc Prev Community Dent       Date:  2018-11-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.