Literature DB >> 26014886

Instantaneous room temperature bonding of a wide range of non-silicon substrates with poly(dimethylsiloxane) (PDMS) elastomer mediated by a mercaptosilane.

Wenming Wu1, Jing Wu, Jae-Heon Kim, Nae Yoon Lee.   

Abstract

This paper introduces an instantaneous and robust strategy for bonding a variety of non-silicon substrates such as thermoplastics, metals, an alloy, and ceramics to poly(dimethylsiloxane) (PDMS) irreversibly, mediated by one-step chemical modification using a mercaptosilane at room temperature followed by corona treatment to realize heterogeneous assembly also at room temperature. The mercapto functional group is one of the strongest nucleophiles, and it can instantaneously react with electrophiles of substrates, resulting in an alkoxysilane-terminated substrate at room temperature. In this way, prior oxidation of the substrate is dispensed with, and the alkoxysilane-terminated substrate can be readily oxidized and irreversibly bonded with oxidized PDMS at room temperature. A commercially available Tesla coil was used for surface oxidation, replacing a bulky and expensive plasma generator. Surface characterization was conducted by water contact angle measurement and X-ray photoelectron spectroscopy (XPS) analysis. A total of fifteen non-silicon substrates including polycarbonate (PC), two types of poly(vinylchloride) (PVC), poly(methylmethacrylate) (PMMA), polystyrene (PS), polyimide (PI), two types of poly(ethylene terephthalate) (PET), polypropylene (PP), iron (Fe), aluminum (Al), copper (Cu), brass, alumina (Al2O3), and zirconia (ZrO2) were bonded successfully with PDMS using this method, and the bond strengths of PDMS-PMMA, PDMS-PC, PDMS-PVC, PDMS-PET, PDMS-Al, and PDMS-Cu assemblies were measured to be approximately 335.9, 511.4, 467.3, 476.4, 282.2, and 236.7 kPa, respectively. The overall processes including surface modification followed by surface oxidation using corona treatment for bonding were realized within 12 to 17 min for most of the substrates tested except for ceramics which required 1 h for the bonding. In addition, large area (10 × 10 cm(2)) bonding was also successfully realized, ensuring the high reliability and stability of the introduced method.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26014886     DOI: 10.1039/c5lc00285k

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  10 in total

1.  Plasma free reversible and irreversible microfluidic bonding.

Authors:  M Chu; T T Nguyen; E K Lee; J L Morival; M Khine
Journal:  Lab Chip       Date:  2017-01-17       Impact factor: 7.517

2.  Diameter-definable tubing-microchips for applications in both continuous-flow and TEC-modulated on-chip qPCRs with reaction signal analyzed between different types of Teflon-polymers: PTFE and FEP.

Authors:  Yangyang Jiang; Guizhu Wu; Yuanming Li; Wenming Wu
Journal:  RSC Adv       Date:  2019-01-21       Impact factor: 3.361

3.  Low-Cost Battery-Powered and User-Friendly Real-Time Quantitative PCR System for the Detection of Multigene.

Authors:  Junru An; Yangyang Jiang; Bing Shi; Di Wu; Wenming Wu
Journal:  Micromachines (Basel)       Date:  2020-04-21       Impact factor: 2.891

4.  Heat and pressure-resistant room temperature irreversible sealing of hybrid PDMS-thermoplastic microfluidic devices via carbon-nitrogen covalent bonding and its application in a continuous-flow polymerase chain reaction.

Authors:  Rajamanickam Sivakumar; Kieu The Loan Trinh; Nae Yoon Lee
Journal:  RSC Adv       Date:  2020-04-25       Impact factor: 3.361

5.  Fabrication of a microfluidic chip based on the pure polypropylene material.

Authors:  Fupeng Liang; Yi Qiao; Mengqin Duan; An Ju; Na Lu; Junji Li; Jing Tu; Zuhong Lu
Journal:  RSC Adv       Date:  2018-02-27       Impact factor: 4.036

6.  Self-regenerating and hybrid irreversible/reversible PDMS microfluidic devices.

Authors:  Letícia S Shiroma; Maria H O Piazzetta; Gerson F Duarte-Junior; Wendell K T Coltro; Emanuel Carrilho; Angelo L Gobbi; Renato S Lima
Journal:  Sci Rep       Date:  2016-05-16       Impact factor: 4.379

7.  Transparent, abrasion-insensitive superhydrophobic coatings for real-world applications.

Authors:  Dorothea Helmer; Nico Keller; Frederik Kotz; Friederike Stolz; Christian Greiner; Tobias M Nargang; Kai Sachsenheimer; Bastian E Rapp
Journal:  Sci Rep       Date:  2017-11-08       Impact factor: 4.379

8.  Wireless, Flexible, Ion-Selective Electrode System for Selective and Repeatable Detection of Sodium.

Authors:  Hyo-Ryoung Lim; Yun-Soung Kim; Shinjae Kwon; Musa Mahmood; Young-Tae Kwon; Yongkuk Lee; Soon Min Lee; Woon-Hong Yeo
Journal:  Sensors (Basel)       Date:  2020-06-10       Impact factor: 3.576

9.  Organic transistor platform with integrated microfluidics for in-line multi-parametric in vitro cell monitoring.

Authors:  Vincenzo F Curto; Bastien Marchiori; Adel Hama; Anna-Maria Pappa; Magali P Ferro; Marcel Braendlein; Jonathan Rivnay; Michel Fiocchi; George G Malliaras; Marc Ramuz; Róisín M Owens
Journal:  Microsyst Nanoeng       Date:  2017-08-14       Impact factor: 7.127

10.  Pressure-Free Assembling of Poly(methyl methacrylate) Microdevices via Microwave-Assisted Solvent Bonding and Its Biomedical Applications.

Authors:  Kieu The Loan Trinh; Woo Ri Chae; Nae Yoon Lee
Journal:  Biosensors (Basel)       Date:  2021-12-20
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.