Literature DB >> 26011923

Diagnostic accuracy of cervical elastography in predicting labor induction success: a systematic review and meta-analysis.

Ambrogio P Londero, Ralf Schmitz, Serena Bertozzi, Lorenza Driul, Arrigo Fruscalzo.   

Abstract

AIM: To determine the accuracy of cervical elastography in predicting labor induction success.
MATERIALS AND METHODS: A systematic search, review, and meta-analysis of observational studies published in English language between January 2000 and October 2014 was performed. It included studies considering cervix sonoelastography as the index test and successful labor or vaginal delivery as the reference standard. As cervix length and Bishop score were considered comparator tests, the quality of the included studies was assessed using quality assessment tool for diagnostic accuracy studies (QUADAS) tool.
RESULTS: A total of four studies assessing 323 women before medical induction of labor were included. Cervical elastography, cervical length, and Bishop score showed a diagnostic odds ratio (DOR) with 95% confidence interval (CI) for successful labor prediction of 3.50 (1.93-6.35), 3.35 (1.94-5.77), and 1.45 (0.33-6.41), respectively. In addition, cervical elastography, cervical length, and Bishop score showed a DOR with 95% CI for successful vaginal delivery prediction of 5.24 (3.23-8.50), 4.94 (2.72-8.98), and 4.62 (0.69-30.94), respectively. Considering the summary of receiver operating characteristic curves we show that cervical elastography or length are similarly reliable, and both are more reliable to predict successful labor than the Bishop score. Two studies were excluded because it was not possible to retrieve data for the meta-analysis. Among the excluded studies, one found no significant contribution from elastography for prediction of successful labor induction.
CONCLUSIONS: Even though there is a limited number of studies included and the heterogeneity of the methods used, cervical elastography seems to be a promising tool for predicting successful labor induction and vaginal delivery in women treated by medical induction of labor.

Entities:  

Mesh:

Year:  2016        PMID: 26011923     DOI: 10.1515/jpm-2015-0035

Source DB:  PubMed          Journal:  J Perinat Med        ISSN: 0300-5577            Impact factor:   1.901


  8 in total

1.  Cervical Evaluation: From Ancient Medicine to Precision Medicine.

Authors:  Helen Feltovich
Journal:  Obstet Gynecol       Date:  2017-07       Impact factor: 7.661

Review 2.  Cervical elastography during pregnancy: a critical review of current approaches with a focus on controversies and limitations.

Authors:  Arrigo Fruscalzo; Edoardo Mazza; Helen Feltovich; Ralf Schmitz
Journal:  J Med Ultrason (2001)       Date:  2016-06-03       Impact factor: 1.314

3.  A soft cervix, categorized by shear-wave elastography, in women with short or with normal cervical length at 18-24 weeks is associated with a higher prevalence of spontaneous preterm delivery.

Authors:  Edgar Hernandez-Andrade; Eli Maymon; Suchaya Luewan; Gaurav Bhatti; Mohammad Mehrmohammadi; Offer Erez; Percy Pacora; Bogdan Done; Sonia S Hassan; Roberto Romero
Journal:  J Perinat Med       Date:  2018-07-26       Impact factor: 2.716

Review 4.  Cervical elastography during pregnancy: clinical perspectives.

Authors:  Malgorzata Swiatkowska-Freund; Krzysztof Preis
Journal:  Int J Womens Health       Date:  2017-04-21

5.  Intracervical Foley catheter balloon versus dinoprostone insert for induction cervical ripening: A systematic review and meta-analysis of randomized controlled trials.

Authors:  Lixia Zhu; Cong Zhang; Fang Cao; Qin Liu; Xing Gu; Jianhao Xu; Jianqing Li
Journal:  Medicine (Baltimore)       Date:  2018-11       Impact factor: 1.817

6.  Diagnostic accuracy of cervical elastography in predicting preterm delivery: A systematic review and meta-analysis.

Authors:  Bo Wang; Yong Zhang; Shuangshuang Chen; Xiaowei Xiang; Juan Wen; Mei Yi; Baiyun He; Bing Hu
Journal:  Medicine (Baltimore)       Date:  2019-07       Impact factor: 1.817

7.  The predictive value of cervical shear wave elastography in the outcome of labor induction.

Authors:  Jing Lu; Yvonne Kwun Yue Cheng; Sin Yee Stella Ho; Daljit Singh Sahota; L L Hui; Liona C Poon; Tak Yeung Leung
Journal:  Acta Obstet Gynecol Scand       Date:  2019-11-05       Impact factor: 3.636

8.  Predictive value of cervical length by ultrasound and cervical strain elastography in labor induction at term.

Authors:  Yimin Zhou; Neng Jin; Qinqing Chen; Min Lv; Ying Jiang; Yuan Chen; Fangfang Xi; Mengmeng Yang; Baihui Zhao; Hefeng Huang; Qiong Luo
Journal:  J Int Med Res       Date:  2021-02       Impact factor: 1.671

  8 in total