Literature DB >> 26010892

An improved method for estimating antibody titers in microneutralization assay using green fluorescent protein.

Hongmei Yang1, Steven F Baker2, Mario E González2, David J Topham2, Luis Martínez-Sobrido2, Martin Zand2, Jeanne Holden-Wiltse1, Hulin Wu1.   

Abstract

Viruses that express reporter genes upon infection have been recently used to evaluate neutralizing antibody responses, where a lack of reporter expression indicates specific virus inhibition. The traditional model-based methods using standard outcome of percent neutralization could be applied to the data from the assays to estimate antibody titers. However, the data produced are sometimes irregular, which can yield meaningless outcomes of percent neutralization that do not fit the typical curves for immunoassays, making automated or semi-high throughput antibody titer estimation unreliable. We developed a type of new outcomes model, which is biologically meaningful and fits typical immunoassay curves well. Our simulation study indicates that the new response approach outperforms the traditional response approach regardless of the data variability. The proposed new response approach can be used in similar assays for other disease models.

Entities:  

Keywords:  Antibody-mediated virus inhibition; four-parameter logistic regression; green fluorescent protein (GFP); hemagglutinin (HA); influenza virus; microneutralization assay; neutralizing antibodies; nonlinear maximization

Mesh:

Substances:

Year:  2015        PMID: 26010892      PMCID: PMC4661136          DOI: 10.1080/10543406.2015.1052475

Source DB:  PubMed          Journal:  J Biopharm Stat        ISSN: 1054-3406            Impact factor:   1.051


  24 in total

1.  Statistical analysis of radioligand assay data.

Authors:  D Rodbard; G R Frazier
Journal:  Methods Enzymol       Date:  1975       Impact factor: 1.600

2.  Quantifying adenovirus-neutralizing antibodies by luciferase transgene detection: addressing preexisting immunity to vaccine and gene therapy vectors.

Authors:  Mieke C Sprangers; Wandena Lakhai; Wouter Koudstaal; Marielle Verhoeven; Björn F Koel; Ronald Vogels; Jaap Goudsmit; Menzo J E Havenga; Stefan Kostense
Journal:  J Clin Microbiol       Date:  2003-11       Impact factor: 5.948

3.  Radioligand Assay.

Authors:  D J Finney
Journal:  Biometrics       Date:  1976-12       Impact factor: 2.571

4.  Statistical analysis of radioimmunoassay data.

Authors:  M J Healy
Journal:  Biochem J       Date:  1972-11       Impact factor: 3.857

5.  Use of bacteriophage particles displaying influenza virus hemagglutinin for the detection of hemagglutination-inhibition antibodies.

Authors:  William Domm; Matthew Brewer; Steven F Baker; Changyong Feng; Luis Martínez-Sobrido; John Treanor; Stephen Dewhurst
Journal:  J Virol Methods       Date:  2013-12-06       Impact factor: 2.014

6.  Use of GFP-expressing influenza viruses for the detection of influenza virus A/H5N1 neutralizing antibodies.

Authors:  Guus F Rimmelzwaan; R Joyce Verburgh; Nella J Nieuwkoop; Theo M Bestebroer; Ron A M Fouchier; Albert D M E Osterhaus
Journal:  Vaccine       Date:  2011-03-09       Impact factor: 3.641

7.  Identification of two cross-neutralizing linear epitopes within the L1 major capsid protein of human papillomaviruses.

Authors:  Alba-Lucia Combita; Antoine Touzé; Latifa Bousarghin; Neil D Christensen; Pierre Coursaget
Journal:  J Virol       Date:  2002-07       Impact factor: 5.103

8.  Influenza A and B virus intertypic reassortment through compatible viral packaging signals.

Authors:  Steven F Baker; Aitor Nogales; Courtney Finch; Kevin M Tuffy; William Domm; Daniel R Perez; David J Topham; Luis Martínez-Sobrido
Journal:  J Virol       Date:  2014-07-09       Impact factor: 5.103

9.  Induction of CD8 T cell heterologous protection by a single dose of single-cycle infectious influenza virus.

Authors:  Hailong Guo; Steven F Baker; Luis Martínez-Sobrido; David J Topham
Journal:  J Virol       Date:  2014-08-06       Impact factor: 5.103

10.  Protection against lethal influenza with a viral mimic.

Authors:  Steven F Baker; Hailong Guo; Randy A Albrecht; Adolfo García-Sastre; David J Topham; Luis Martínez-Sobrido
Journal:  J Virol       Date:  2013-05-29       Impact factor: 5.103

View more
  3 in total

1.  Mechanical gating of the auditory transduction channel TMC1 involves the fourth and sixth transmembrane helices.

Authors:  Nurunisa Akyuz; K Domenica Karavitaki; Bifeng Pan; Panos I Tamvakologos; Kelly P Brock; Yaqiao Li; Debora S Marks; David P Corey
Journal:  Sci Adv       Date:  2022-07-13       Impact factor: 14.957

2.  Rapid in vitro assays for screening neutralizing antibodies and antivirals against SARS-CoV-2.

Authors:  Jun-Gyu Park; Fatai S Oladunni; Kevin Chiem; Chengjin Ye; Michael Pipenbrink; Thomas Moran; Mark R Walter; James Kobie; Luis Martinez-Sobrido
Journal:  J Virol Methods       Date:  2020-10-14       Impact factor: 2.014

3.  Virus Reduction Neutralization Test: A Single-Cell Imaging High-Throughput Virus Neutralization Assay for Dengue.

Authors:  Melissa C Whiteman; Leah Bogardus; Danila G Giacone; Leonard J Rubinstein; Joseph M Antonello; Dengyun Sun; Sarah Daijogo; Kevin B Gurney
Journal:  Am J Trop Med Hyg       Date:  2018-12       Impact factor: 2.345

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.