Literature DB >> 26009918

Effects of implant morphology on rotational stability during immediate implant placement in the esthetic zone.

Joseph Yk Kan, Phillip Roe, Kitichai Rungcharassaeng.   

Abstract

PURPOSE: Primary implant stability is critical to achieving implant success, especially in a situation with immediate implant placement and provisionalization (IIPP) when bone quality and quantity are compromised. The purpose of this study was to examine the effects of implant morphology (tapered vs cylindric) and the final drill-implant diameter discrepancy (FD-IDD) of six implant systems on the incidence of rotational instability during IIPP in the esthetic zone.
MATERIALS AND METHODS: One hundred seventy-one implants in 112 patients were evaluated. Implants that exhibited inadequate resistance to the torque generated by the surgeon's hand during implant placement were classified as rotationally unstable.
RESULTS: The overall incidence of rotational instability for the tapered implants (1.1%) was significantly lower than that exhibited by the cylindric (nontapered) implants (20.5%). Among the cylindric implants, those with < 0.5 mm FD-IDD experienced a significantly higher incidence of rotational instability (36.6%) than groups with ≥ 0.5 mm FD-IDD. The incidence of rotational instability of cylindric implants with ≥ 0.5 mm FD-IDD was significantly greater than that of the tapered implants with a comparable FD-IDD.
CONCLUSION: Within the confines of this study, the use of a tapered implant with an FD-IDD of ≥ 0.5 mm minimized the incidence of rotational implant instability for the IIPP procedure.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26009918     DOI: 10.11607/jomi.3885

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  Accuracy and primary stability of tapered or straight implants placed into fresh extraction socket using dynamic navigation: a randomized controlled clinical trial.

Authors:  Shi-Min Wei; Jun-Yu Shi; Shi-Chong Qiao; Xiao Zhang; Hong-Chang Lai; Xiao-Meng Zhang
Journal:  Clin Oral Investig       Date:  2021-11-19       Impact factor: 3.573

2.  Radiographic Comparison of Bovine Bone Substitute Alone Versus Bovine Bone Substitute and Simvastatin for Human Maxillary Sinus Augmentation.

Authors:  Siamak Yaghobee; Amir Ali Reza Rasouli Ghahroudi; Afshin Khorsand; Sanaz Mahmoudi; Sahar Chokami Rafiei
Journal:  J Dent (Tehran)       Date:  2018-01

3.  Secondary implant stability outcome of immediate versus late placed variable-thread implants in the maxilla. A retrospective cohort study.

Authors:  Nicolas Grognard; Gino Verleye; Dimitrios Mavreas; Bart Vande-Vannet
Journal:  J Clin Exp Dent       Date:  2017-09-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.