Influence of tidal volume on ventilation inhomogeneity assessed by electrical impedance tomography during controlled mechanical ventilation.

T Becher1, M Kott, D Schädler, B Vogt, T Meinel, N Weiler, I Frerichs.   

Abstract

The global inhomogeneity (GI) index is a parameter of ventilation inhomogeneity that can be calculated from images of tidal ventilation distribution obtained by electrical impedance tomography (EIT). It has been suggested that the GI index may be useful for individual adjustment of positive end-expiratory pressure (PEEP) and for guidance of ventilator therapy. The aim of the present work was to assess the influence of tidal volume (VT) on the GI index values. EIT data from 9 patients with acute respiratory distress syndrome ventilated with a low and a high VT of 5   ±   1 (mean  ±  SD) and 9   ±   1 ml kg(-1) predicted body weight at a high and a low level of PEEP (PEEPhigh, PEEPlow) were analyzed. PEEPhigh and PEEPlow were set 2 cmH2O above and 5 cmH2O below the lower inflection point of a quasi-static pressure volume loop, respectively. The lower inflection point was identified at 8.1   ±   1.4 (mean  ±  SD) cmH2O, resulting in a PEEPhigh of 10.1   ±   1.4 and a PEEPlow of 3.1   ±   1.4 cmH2O. At PEEPhigh, we found no significant trend in GI index with low VT when compared to high VT (0.49   ±   0.15 versus 0.44   ±   0.09, p = 0.13). At PEEPlow, we found a significantly higher GI index with low VT compared to high VT (0.66   ±   0.19 versus 0.59   ±   0.17, p = 0.01). When comparing the PEEP levels, we found a significantly lower GI index at PEEPhigh both for high and low VT. We conclude that high VT may lead to a lower GI index, especially at low PEEP settings. This should be taken into account when using the GI index for individual adjustment of ventilator settings.

Entities:  

Mesh:

Year:  2015        PMID: 26007294     DOI: 10.1088/0967-3334/36/6/1137

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  7 in total

1.  Ventilation inhomogeneity in obstructive lung diseases measured by electrical impedance tomography: a simulation study.

Authors:  B Schullcke; S Krueger-Ziolek; B Gong; R A Jörres; U Mueller-Lisse; K Moeller
Journal:  J Clin Monit Comput       Date:  2017-10-10       Impact factor: 2.502

2.  Lung regions identified with CT improve the value of global inhomogeneity index measured with electrical impedance tomography.

Authors:  Lin Yang; Meng Dai; Knut Möller; Inéz Frerichs; Andy Adler; Feng Fu; Zhanqi Zhao
Journal:  Quant Imaging Med Surg       Date:  2021-04

3.  Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies.

Authors:  Tobias Becher; Barbara Vogt; Matthias Kott; Dirk Schädler; Norbert Weiler; Inéz Frerichs
Journal:  PLoS One       Date:  2016-03-24       Impact factor: 3.240

4.  Associations between positive end-expiratory pressure and outcome of patients without ARDS at onset of ventilation: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Ary Serpa Neto; Roberto Rabello Filho; Thomas Cherpanath; Rogier Determann; Dave A Dongelmans; Frederique Paulus; Pieter Roel Tuinman; Paolo Pelosi; Marcelo Gama de Abreu; Marcus J Schultz
Journal:  Ann Intensive Care       Date:  2016-11-03       Impact factor: 6.925

5.  Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group.

Authors:  Inéz Frerichs; Marcelo B P Amato; Anton H van Kaam; David G Tingay; Zhanqi Zhao; Bartłomiej Grychtol; Marc Bodenstein; Hervé Gagnon; Stephan H Böhm; Eckhard Teschner; Ola Stenqvist; Tommaso Mauri; Vinicius Torsani; Luigi Camporota; Andreas Schibler; Gerhard K Wolf; Diederik Gommers; Steffen Leonhardt; Andy Adler
Journal:  Thorax       Date:  2016-09-05       Impact factor: 9.139

6.  Fast detection and data compensation for electrodes disconnection in long-term monitoring of dynamic brain electrical impedance tomography.

Authors:  Ge Zhang; Meng Dai; Lin Yang; Weichen Li; Haoting Li; Canhua Xu; Xuetao Shi; Xiuzhen Dong; Feng Fu
Journal:  Biomed Eng Online       Date:  2017-01-07       Impact factor: 2.819

7.  Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position.

Authors:  Andrej Šribar; Vlasta Merc; Zoran Peršec; Jasminka Peršec; Ivan Milas; Sanja Husedžinović
Journal:  J Clin Monit Comput       Date:  2019-05-06       Impact factor: 2.502