Literature DB >> 26007150

Tracking boundary movement and exterior shape modelling in lung EIT imaging.

A Biguri1, B Grychtol, A Adler, M Soleimani.   

Abstract

Electrical impedance tomography (EIT) has shown significant promise for lung imaging. One key challenge for EIT in this application is the movement of electrodes during breathing, which introduces artefacts in reconstructed images. Various approaches have been proposed to compensate for electrode movement, but no comparison of these approaches is available. This paper analyses boundary model mismatch and electrode movement in lung EIT. The aim is to evaluate the extent to which various algorithms tolerate movement, and to determine if a patient specific model is required for EIT lung imaging. Movement data are simulated from a CT-based model, and image analysis is performed using quantitative figures of merit. The electrode movement is modelled based on expected values of chest movement and an extended Jacobian method is proposed to make use of exterior boundary tracking. Results show that a dynamical boundary tracking is the most robust method against any movement, but is computationally more expensive. Simultaneous electrode movement and conductivity reconstruction algorithms show increased robustness compared to only conductivity reconstruction. The results of this comparative study can help develop a better understanding of the impact of shape model mismatch and electrode movement in lung EIT.

Entities:  

Mesh:

Year:  2015        PMID: 26007150     DOI: 10.1088/0967-3334/36/6/1119

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  Electrical Impedance Tomography-Based Abdominal Subcutaneous Fat Estimation Method Using Deep Learning.

Authors:  Kyounghun Lee; Minha Yoo; Ariungerel Jargal; Hyeuknam Kwon
Journal:  Comput Math Methods Med       Date:  2020-06-11       Impact factor: 2.238

2.  Evaluation of electrical impedance tomography for determination of urinary bladder volume: comparison with standard ultrasound methods in healthy volunteers.

Authors:  Dorothea Leonhäuser; Carlos Castelar; Thomas Schlebusch; Martin Rohm; Rüdiger Rupp; Steffen Leonhardt; Marian Walter; Joachim O Grosse
Journal:  Biomed Eng Online       Date:  2018-07-13       Impact factor: 2.819

3.  A Point-Matching Method of Moment with Sparse Bayesian Learning Applied and Evaluated in Dynamic Lung Electrical Impedance Tomography.

Authors:  Christos Dimas; Vassilis Alimisis; Nikolaos Uzunoglu; Paul P Sotiriadis
Journal:  Bioengineering (Basel)       Date:  2021-11-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.