Literature DB >> 26006181

A comparison framework for temporal image reconstructions in electrical impedance tomography.

Hervé Gagnon1, Bartłomiej Grychtol, Andy Adler.   

Abstract

Electrical impedance tomography (EIT) provides low-resolution images of internal conductivity distributions, but is able to achieve relatively high temporal resolutions. Most EIT image reconstruction algorithms do not explicitly account for the temporal constraints on the measurements or physiological processes under investigation. Instead, algorithms typically assume both that the conductivity distribution does not change during the acquisition of each EIT data frame, and that frames can be reconstructed independently, without consideration of the correlation between images. A failure to account for these temporal effects will result in aliasing-related artefacts in images. Several methods have been proposed to compensate for these effects, including interpolation of raw data, and reconstruction algorithms using Kalman and temporal filtering. However, no systematic work has been performed to understand the severity of the temporal artefacts nor the extent to which algorithms can account for them. We seek to address this need by developing a temporal comparison framework and figures of merit to assess the ability of reconstruction algorithms to account for temporal effects. Using this approach, we compare combinations of three reconstruction algorithms using three EIT data frame types: perfect, realistic and interpolated. The results show that, without accounting for temporal effects, artefacts are present in images for dynamic conductivity contrasts at frequencies 10-20 times slower than the frame rate. The proposed methods show some improvements in reducing these artefacts.

Entities:  

Mesh:

Year:  2015        PMID: 26006181     DOI: 10.1088/0967-3334/36/6/1093

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  2 in total

1.  Effects of individualized electrical impedance tomography and image reconstruction settings upon the assessment of regional ventilation distribution: Comparison to 4-dimensional computed tomography in a porcine model.

Authors:  Florian Thürk; Stefan Boehme; Daniel Mudrak; Stefan Kampusch; Alice Wielandner; Helmut Prosch; Christina Braun; Frédéric P R Toemboel; Johannes Hofmanninger; Eugenijus Kaniusas
Journal:  PLoS One       Date:  2017-08-01       Impact factor: 3.240

2.  Extended Joint Sparsity Reconstruction for Spatial and Temporal ERT Imaging.

Authors:  Bo Chen; Juan F P J Abascal; Manuchehr Soleimani
Journal:  Sensors (Basel)       Date:  2018-11-17       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.