Literature DB >> 26004629

Reliability and fatigue characteristics of a standing hip isometric endurance protocol.

Jessica A Mutchler1, Joshua T Weinhandl2, Matthew C Hoch3, Bonnie L Van Lunen3.   

Abstract

Muscle fatigue is a common consideration when evaluating and rehabilitating athletic injuries. The presence of muscular fatigue has been previously determined by quantifying median frequency (MF) through a power spectral analysis on EMG signals collected throughout an endurance task. Research has not yet determined if a prolonged isometric test in a standing position generates muscular fatigue of the hip. The purpose of this study was to determine the reliability and fatigue characteristics of a standing hip isometric endurance test. Twenty healthy participants completed one 60-s Maximum Voluntary Isometric Contraction of standing hip flexion, extension, adduction, and abduction. MF of the participants' dominant limb rectus femoris (RF), biceps femoris (BF), gluteus maximus (GMax), gluteus medius (GMed) and adductor longus (ADD) was determined via surface electromyography during two sessions, 30-min apart. Reliability values (ICC2,1) were moderate-to-excellent for all time intervals of each action (FlexionRF: >0.80; ExtensionBF: >0.89; ExtensionGMax: >0.60; AdductionADD: >0.78; AbductionGMed: >0.60) and MF significantly decreased over time for all actions. Results suggest the endurance test is a reliable technique to generate muscular fatigue for hip flexion, extension, adduction and abduction. It can be used as a time efficient fatigue protocol specific to the RF, BF, GMax, ADD and GMed.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Electromyography; Fatigue; Median frequency

Mesh:

Year:  2015        PMID: 26004629     DOI: 10.1016/j.jelekin.2015.02.003

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  5 in total

1.  Asymmetrical fatiguing of the gluteus maximus muscles in the elite short-track female skaters.

Authors:  Mariusz Konieczny; Paweł Pakosz; Mateusz Witkowski
Journal:  BMC Sports Sci Med Rehabil       Date:  2020-08-14

2.  Validating the Cambridge Protocol: Reliability of Hip Muscle Strength Measurements Using a Motorized Dynamometer and Electromyography.

Authors:  Arman Memarzadeh; Andrew Paul Morrison; Viviane Merzbach; Michael Ferrandino; Arvind Arora; Leica S Claydon-Mueller; Vikas Khanduja
Journal:  Sports Health       Date:  2022-02-01       Impact factor: 4.355

3.  A Comparative Study of EMG Indices in Muscle Fatigue Evaluation Based on Grey Relational Analysis during All-Out Cycling Exercise.

Authors:  Lejun Wang; Yuting Wang; Aidi Ma; Guoqiang Ma; Yu Ye; Ruijie Li; Tianfeng Lu
Journal:  Biomed Res Int       Date:  2018-04-16       Impact factor: 3.411

4.  Immunomodulatory placental-expanded, mesenchymal stromal cells improve muscle function following hip arthroplasty.

Authors:  Tobias Winkler; Carsten Perka; Philipp von Roth; Alison N Agres; Henning Plage; Bernd Preininger; Matthias Pumberger; Sven Geissler; Esther Lukasiewicz Hagai; Racheli Ofir; Lena Pinzur; Eli Eyal; Gisela Stoltenburg-Didinger; Christian Meisel; Christine Consentius; Mathias Streitz; Petra Reinke; Georg N Duda; Hans-Dieter Volk
Journal:  J Cachexia Sarcopenia Muscle       Date:  2018-09-19       Impact factor: 12.910

5.  RELIABILITY AND VALIDITY OF THE HIP ABDUCTOR ISOMETRIC ENDURANCE TEST: A NEW METHOD TO ASSESS THE ENDURANCE OF THE HIP ABDUCTORS.

Authors:  Joachim Van Cant; Christine Detrembleur; Philippe Mahaudens; Véronique Feipel
Journal:  Int J Sports Phys Ther       Date:  2020-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.