Literature DB >> 26004284

Feasibility study of high-resolution DCE-MRI for glomerular filtration rate (GFR) measurement in a routine clinical modal.

Yu-Dong Zhang1, Chen-Jiang Wu2, Jing Zhang3, Xiao-Ning Wang4, Xi-Sheng Liu5, Hai-Bin Shi6.   

Abstract

Dynamic contrast enhanced (DCE) MR renography has been identified as an interesting tool to determine single-kidney GFR. However, a fundamental issue for the applicability of MR-based estimate of single-kidney GFR is selecting a balance between spatial and temporal resolution of DCE-MRI data. The purpose is to assess the feasibility of GFR estimate from high-resolution (HR) dynamic contrast-enhanced (DCE) MRI in a routine clinical modal. Standard MR renography (2.4s/phase, total 4min; 4-ml Gd) and five-phase, HR-based imaging protocol (0, 30, 70, 120, and 240s; 0.05mmol/kg Gd) were prospectively performed in twelve volunteers who were scheduled for routine renal MRI. Data were plotted with Patlak, two-compartment modified Tofts model (2CTM), and two-compartment filtration model (2CFM) for GFR estimate. During all the measurements, only the signal intensities in the aorta and whole kidney parenchyma were considered. Standard 2CFM and 2CTM produced lower residuals over the fitted interval than HR-based measures (p<0.05); and HR-bases 2CFM and 2CTM did not reflect significant correlation to standard values. Standard Patlak plots with 0-240s data points produced significantly lower GFR and higher residuals than that plots with 0-120s data points (p<0.05). HR-based Patlak plots with 0, 30, 70, and 120s data points significantly correlated with reference values (Pearson ρ=0.97, p<0.01), and produced a 33.2% underestimation of reference value, which was better than that plots with 0, 30, 70, 120, and 240s data points (ρ=0.92, p<0.01; 58.6% underestimation of reference value). It concludes that it is feasible to estimate GFR with HR-based DCE-MRI and appreciate kinetic model. Patlak plots from 0, 30, 70, and 120s data points is better than plots from 0, 30, 70, 120, and 240s data points.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  2CTM; GFR; MR renography; Patlak, 2CFM; Renal function

Mesh:

Substances:

Year:  2015        PMID: 26004284     DOI: 10.1016/j.mri.2015.05.005

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  1 in total

1.  Noninvasive measurement of renal blood flow by magnetic resonance imaging in rats.

Authors:  Cesar A Romero; Glauber Cabral; Robert A Knight; Guangliang Ding; Edward L Peterson; Oscar A Carretero
Journal:  Am J Physiol Renal Physiol       Date:  2017-10-04
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.