Exploration of attenuated total reflectance mid-infrared spectroscopy and multivariate calibration to measure immunoglobulin G in human sera.

Siyuan Hou1, Christopher B Riley2, Cynthia A Mitchell1, R Anthony Shaw3, Janet Bryanton4, Kathryn Bigsby5, J Trenton McClure6.   

Abstract

Immunoglobulin G (IgG) is crucial for the protection of the host from invasive pathogens. Due to its importance for human health, tools that enable the monitoring of IgG levels are highly desired. Consequently there is a need for methods to determine the IgG concentration that are simple, rapid, and inexpensive. This work explored the potential of attenuated total reflectance (ATR) infrared spectroscopy as a method to determine IgG concentrations in human serum samples. Venous blood samples were collected from adults and children, and from the umbilical cord of newborns. The serum was harvested and tested using ATR infrared spectroscopy. Partial least squares (PLS) regression provided the basis to develop the new analytical methods. Three PLS calibrations were determined: one for the combined set of the venous and umbilical cord serum samples, the second for only the umbilical cord samples, and the third for only the venous samples. The number of PLS factors was chosen by critical evaluation of Monte Carlo-based cross validation results. The predictive performance for each PLS calibration was evaluated using the Pearson correlation coefficient, scatter plot and Bland-Altman plot, and percent deviations for independent prediction sets. The repeatability was evaluated by standard deviation and relative standard deviation. The results showed that ATR infrared spectroscopy is potentially a simple, quick, and inexpensive method to measure IgG concentrations in human serum samples. The results also showed that it is possible to build a united calibration curve for the umbilical cord and the venous samples.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Immunoglobulin; Infrared spectroscopy; Partial least squares regression; Umbilical cord; Venous

Mesh:

Substances:

Year:  2015        PMID: 26003699     DOI: 10.1016/j.talanta.2015.04.010

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

Review 1.  Vibrational Spectroscopy Fingerprinting in Medicine: from Molecular to Clinical Practice.

Authors:  Vera Balan; Cosmin-Teodor Mihai; Florina-Daniela Cojocaru; Cristina-Mariana Uritu; Gianina Dodi; Doru Botezat; Ioannis Gardikiotis
Journal:  Materials (Basel)       Date:  2019-09-06       Impact factor: 3.623

Review 2.  Advanced Waveguide Based LOC Biosensors: A Minireview.

Authors:  Muzafar A Kanjwal; Amal Al Ghaferi
Journal:  Sensors (Basel)       Date:  2022-07-21       Impact factor: 3.847

3.  An ultrasensitive label-free electrochemical immunosensor based on signal amplification strategy of multifunctional magnetic graphene loaded with cadmium ions.

Authors:  Faying Li; Yueyun Li; Yunhui Dong; Liping Jiang; Ping Wang; Qing Liu; Hui Liu; Qin Wei
Journal:  Sci Rep       Date:  2016-02-16       Impact factor: 4.379

4.  A sandwich-type electrochemical immunosensor based on the biotin- streptavidin-biotin structure for detection of human immunoglobulin G.

Authors:  Yueyun Li; Yihe Zhang; Liping Jiang; Paul K Chu; Yunhui Dong; Qin Wei
Journal:  Sci Rep       Date:  2016-03-07       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.