Literature DB >> 26003231

Influence of the resin cement thickness on the fatigue failure loads of CAD/CAM feldspathic crowns.

Liliana Gressler May1, J Robert Kelly2, Marco Antonio Bottino3, Tom Hill4.   

Abstract

OBJECTIVES: to evaluate the influence of the occlusal resin cement thickness on the cyclic loads-to-failure of feldspathic crowns and to compare the results to data from monotonic tests. A large range of cement thickness (50μm and 500μm) was tested, in order to better measure the influence of this variable.
METHODS: Feldspathic ceramic crowns (Vita Mark II blocks, Vita Zahnfabrik) were bonded to dentin analog dies (G10 (NEMA grade G10, International Paper), with occlusal resin cement thicknesses of 50μm and 500μm (Multilink Automix, Ivoclar). The dies were prepared with microchannels for water transport to the cement layer. After 96-h water storage, the specimens (n=20) were submitted to cyclic loads (500,000 cycles at 20Hz; initial maximum load=40% of monotonic load, from previous data) following a staircase sensitivity design (step size=25N). Failure loads at 500,000 cycles were compared to monotonic failure loads (from a previous study with specimens produced by the same author, using the same materials, specimen configuration and cementation protocol).
RESULTS: Crowns with an occlusal cement layer of 50μm were more resistant than those cemented with 500μm (246.4±22.9N vs. 158.9±22.9N), under wet cyclic testing conditions (p<0.001). The fatigue failure loads were reduced compared to monotonic loads: to 37% of monotonic for 50μm; to 53% of monotonic for 500μm. SIGNIFICANCE: An occlusal cement thickness of 50μm was more favorable for the structural performance of feldspathic crowns than was 500μm. Cyclic fatigue reduced failure loads well below those found under monotonic loading.
Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cement thickness; Ceramic; Crowns; Failure load; Fatigue

Mesh:

Substances:

Year:  2015        PMID: 26003231     DOI: 10.1016/j.dental.2015.04.019

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  10 in total

1.  Marginal and internal fit of feldspathic ceramic CAD/CAM crowns fabricated via different extraoral digitization methods: a micro-computed tomography analysis.

Authors:  Ece İrem Oğuz; Mehmet Ali Kılıçarslan; Mert Ocak; Burak Bilecenoğlu; Zeynep Ekici
Journal:  Odontology       Date:  2020-10-26       Impact factor: 2.634

2.  In-vitro performance of CAD/CAM-fabricated implant-supported temporary crowns.

Authors:  Martin Rosentritt; Philipp Raab; Sebastian Hahnel; Matthias Stöckle; Verena Preis
Journal:  Clin Oral Investig       Date:  2017-01-21       Impact factor: 3.573

3.  Fatigue behavior and stress distribution of molars restored with MOD inlays with and without deep margin elevation.

Authors:  Elisa Donaria Aboucauch Grassi; Guilherme Schmitt de Andrade; João Paulo Mendes Tribst; Renan Vaz Machry; Luiz Felipe Valandro; Nathalia de Carvalho Ramos; Eduardo Bresciani; Guilherme de Siqueira Ferreira Anzaloni Saavedra
Journal:  Clin Oral Investig       Date:  2021-10-13       Impact factor: 3.573

4.  Shear bond strength of zirconia to resin: The effects of specimen preparation and loading procedure.

Authors:  Bingzhuo Chen; Lu Yang; Zhicen Lu; Hongliang Meng; Xinyi Wu; Chen Chen; Haifeng Xie
Journal:  J Adv Prosthodont       Date:  2019-12-18       Impact factor: 1.904

5.  Comparative Evaluation of Adaptation of Esthetic Prefabricated Fiberglass and CAD/CAM Crowns for Primary Teeth: Microcomputed Tomography Analysis.

Authors:  Ece Irem Oguz; Tuğba Bezgin; Ayse Isıl Orhan; Kaan Orhan
Journal:  Biomed Res Int       Date:  2021-09-26       Impact factor: 3.411

6.  Evaluation of the Bond Strength of Densely Sintered Ceramics Subjected to Extended Firing.

Authors:  Samuel Oliveira Costa; Suellen Nogueira Linares Lima; Maria Victória Nassif; Andres Felipe Millan Cardenas; Rudys Rodolfo de Jesus Tavarez; Darlon Martins Lima; Matheus Coelho Bandeca
Journal:  Clin Cosmet Investig Dent       Date:  2021-09-01

7.  Influence of substrate design for in vitro mechanical testing.

Authors:  Amanda-Maria-de Oliveira Dal Piva; João-Paulo-Mendes Tribst; Alexandre-Luiz-Souto Borges; Renata-Marques de Melo; Marco-Antonio Bottino
Journal:  J Clin Exp Dent       Date:  2019-02-01

8.  Effect of Tooth Types on the Accuracy of Dental 3D Scanners: An In Vitro Study.

Authors:  Keunbada Son; Kyu-Bok Lee
Journal:  Materials (Basel)       Date:  2020-04-09       Impact factor: 3.623

9.  Influence of Bioactive, Resin and Glass Ionomer luting cements on the fracture loads of dentin bonded ceramic crowns.

Authors:  Fahim Vohra; Manea Altwaim; Abdulaziz S Alshuwaier; Modhi Al Deeb; Yasser Alfawaz; Mohammed Alrabiah; Tariq Abduljabbar
Journal:  Pak J Med Sci       Date:  2020 Mar-Apr       Impact factor: 1.088

10.  New Intraoral Scanner-Based Chairside Measurement Method to Investigate the Internal Fit of Crowns: A Clinical Trial.

Authors:  Maximiliane Amelie Schlenz; Jonas Vogler; Alexander Schmidt; Peter Rehmann; Bernd Wöstmann
Journal:  Int J Environ Res Public Health       Date:  2020-03-25       Impact factor: 3.390

  10 in total