Literature DB >> 26003020

Impact of Strut Width in Periprocedural Myocardial Infarction: A Propensity-Matched Comparison Between Bioresorbable Scaffolds and the First-Generation Sirolimus-Eluting Stent.

Hiroyoshi Kawamoto1, Vasileios F Panoulas2, Katsumasa Sato1, Tadashi Miyazaki1, Toru Naganuma3, Alessandro Sticchi4, Filippo Figini1, Azeem Latib1, Alaide Chieffo4, Mauro Carlino4, Matteo Montorfano4, Antonio Colombo5.   

Abstract

OBJECTIVES: This study aimed to assess the clinical impact of strut width (evaluated by abluminal strut surface area [ASSA]) on periprocedural myocardial infarction (PMI) and clinical outcomes in patients treated with bioresorbable scaffolds (BRS) versus first-generation sirolimus-eluting stents (SES).
BACKGROUND: To date, there are no reports on the impact of ASSA on PMI and clinical outcomes.
METHODS: We compared the impact of ASSA on outcomes and PMI in propensity-matched patients treated with BRS and SES. The primary outcome was the incidence of major adverse cardiac events (MACE), defined as the combination of all-cause mortality, follow-up myocardial infarction, and target vessel revascularization, at 30-days and 1-year follow-ups. The secondary endpoint was the incidence of PMI.
RESULTS: After propensity-matched analysis, 499 patients (147 BRS patients vs. 352 SES patients) were evaluated. Mean ASSA was higher in patients treated with BRS versus SES (BRS: 132.3 ± 76.7 mm(2) vs. SES: 67.6 ± 48.4 mm(2), p < 0.001). MACE was not significantly different between groups (30-days MACE: BRS: 0% vs. SES: 1.4%, p = 0.16, and 1-year MACE: BRS: 15.7% vs. SES: 11.4%, p = 0.67). The incidence of PMI was significantly higher in the BRS group (BRS: 13.1% vs. SES: 7.5%, p = 0.05). Multivariable analyses indicated that treatment of left anterior descending artery and ASSA were independent predictors of PMI.
CONCLUSIONS: BRS implantation, compared with SES implantation, was associated with a higher incidence of PMI. MACE at 30 days and 1 year were not significantly different. Left anterior descending artery percutaneous coronary intervention and ASSA were independent predictors of PMI.
Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  bioresorbable scaffold; first generation; periprocedural myocardial infarction; sirolimus-eluting stent; strut width

Mesh:

Substances:

Year:  2015        PMID: 26003020     DOI: 10.1016/j.jcin.2015.02.011

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  6 in total

1.  Complex vs. non-complex percutaneous coronary intervention with newer-generation drug-eluting stents: an analysis from the randomized BIOFLOW trials.

Authors:  Rayyan Hemetsberger; Mohammad Abdelghani; Ralph Toelg; Hector M Garcia-Garcia; Serdar Farhan; Nader Mankerious; Karim Elbasha; Abdelhakim Allali; Stephan Windecker; Thierry Lefèvre; Shigeru Saito; David Kandzari; Ron Waksman; Gert Richardt
Journal:  Clin Res Cardiol       Date:  2022-02-25       Impact factor: 5.460

2.  Outcomes of patients treated with a biodegradable-polymer sirolimus-eluting stent versus durable-polymer everolimus-eluting stents after rotational atherectomy.

Authors:  Nader Mankerious; Rayyan Hemetsberger; Hussein Traboulsi; Ralph Toelg; Mohamed Abdel-Wahab; Gert Richardt; Abdelhakim Allali
Journal:  Clin Res Cardiol       Date:  2021-04-16       Impact factor: 5.460

3.  Quantitative assessment of the stent/scaffold strut embedment analysis by optical coherence tomography.

Authors:  Yohei Sotomi; Hiroki Tateishi; Pannipa Suwannasom; Jouke Dijkstra; Jeroen Eggermont; Shengnan Liu; Erhan Tenekecioglu; Yaping Zheng; Mohammad Abdelghani; Rafael Cavalcante; Robbert J de Winter; Joanna J Wykrzykowska; Yoshinobu Onuma; Patrick W Serruys; Takeshi Kimura
Journal:  Int J Cardiovasc Imaging       Date:  2016-02-22       Impact factor: 2.357

4.  Twelve-month comparative analysis of clinical outcomes using biodegradable polymer-coated everolimus-eluting stents versus durable polymer-coated everolimus-eluting stents in all-comer patients.

Authors:  Atul Abhyankar; Manjinder Singh Sandhu; Raghava Sarma Polavarapu
Journal:  Indian Heart J       Date:  2019-05-03

5.  Early experience and favorable clinical outcomes of everolimus-eluting bioresorbable scaffolds for coronary artery disease in Korea.

Authors:  Osung Kwon; Jung-Min Ahn; Do-Yoon Kang; Se Hun Kang; Pil Hyung Lee; Soo-Jin Kang; Seung-Whan Lee; Young-Hak Kim; Cheol Whan Lee; Seong-Wook Park; Duk-Woo Park; Seung-Jung Park
Journal:  Korean J Intern Med       Date:  2017-11-07       Impact factor: 2.884

6.  Ultrathin-strut biodegradable polymer versus durable polymer drug-eluting stents: a meta-analysis.

Authors:  Mohammad Riashad Monjur; Christian F Said; Paul Bamford; Michael Parkinson; Richard Szirt; Thomas Ford
Journal:  Open Heart       Date:  2020-10
  6 in total