X-ray phase-contrast computed tomography of human coronary arteries.

Holger Hetterich1, Marian Willner, Christopher Habbel, Julia Herzen, Verena S Hoffmann, Sandra Fill, Alexander Hipp, Mathias Marschner, Ulrich Schüller, Sigrid Auweter, Steffen Massberg, Maximilian F Reiser, Franz Pfeiffer, Tobias Saam, Fabian Bamberg.   

Abstract

OBJECTIVE: The objective of this study was to assess the potential of grating-based phase-contrast computed tomography (gb-PCCT) for the detection and characterization of human coronary artery disease in an experimental ex vivo validation study.
MATERIALS AND METHODS: The study was approved by the institutional review board, and informed consent was obtained from all patients. Specimens were examined using a conventional low-coherence x-ray tube (40 kV) and a Talbot-Lau grating interferometer. Histopathologic assessment was used as the standard of reference. Signal characteristics of calcified, fibrous (FIB), and lipid-rich (LIP) tissue were visually and quantitatively assessed by phase-contrast Hounsfield units (HU). Conventional absorption-based HU values were also measured. Conservative measurements of diagnostic accuracy for the detection and differentiation of plaque components as well as quantitative measurements of vessel dimensions were obtained, and receiver operating characteristic curve analysis for plaque differentiation was performed.
RESULTS: A total of 15 coronary arteries from 5 subjects were available for analysis (386 sections). Calcified, FIB, and LIP displayed distinct gb-PCCT signal criteria. The diagnostic accuracy of gb-PCCT was high with sensitivity, specificity, and negative and positive predictive values of 0.89 or greater for all plaque components with good interrater agreement (к ≥ 0.88). In addition, quantitative measurements of vessel dimensions in gb-PCCT were strongly correlated with measurements obtained from histopathology (Pearson R ≥ 0.86). Finally, phase-contrast Hounsfield units were superior to conventional HU in differentiating FIB and LIP (receiver operating characteristic analysis, 0.86 vs. 0.77, respectively; P < 0.05).
CONCLUSIONS: In an ex vivo setting, gb-PCCT provides improved differentiation and quantification of coronary atherosclerotic plaque and may thus serve as a tool for nondestructive histopathology.

Entities:  

Mesh:

Year:  2015        PMID: 26002622     DOI: 10.1097/RLI.0000000000000169

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  7 in total

Review 1.  [X‑ray Phase Contrast : Principles, potential and advances in clinical translation].

Authors:  F Pfeiffer; M Reiser; E Rummeny
Journal:  Radiologe       Date:  2018-03       Impact factor: 0.635

2.  Trends in radiology and experimental research.

Authors:  Francesco Sardanelli
Journal:  Eur Radiol Exp       Date:  2017-06-29

3.  Fast X-ray Differential Phase Contrast Imaging with One Exposure and without Movements.

Authors:  Jian Fu; Xianhong Shi; Wei Guo; Peng Peng
Journal:  Sci Rep       Date:  2019-02-04       Impact factor: 4.379

4.  Cellular-resolution 3D virtual histology of human coronary arteries using x-ray phase tomography.

Authors:  William Vågberg; Jonas Persson; Laszlo Szekely; Hans M Hertz
Journal:  Sci Rep       Date:  2018-07-20       Impact factor: 4.379

5.  Ex vivo evaluation of an atherosclerotic human coronary artery via histology and high-resolution hard X-ray tomography.

Authors:  Marzia Buscema; Simone E Hieber; Georg Schulz; Hans Deyhle; Alexander Hipp; Felix Beckmann; Johannes A Lobrinus; Till Saxer; Bert Müller
Journal:  Sci Rep       Date:  2019-10-04       Impact factor: 4.379

6.  In vivo assessment of inflammation in carotid atherosclerosis by noninvasive photoacoustic imaging.

Authors:  Zhihua Xie; Yanqing Yang; Yaqiong He; Chengyou Shu; Dong Chen; Jinke Zhang; Jingqin Chen; Chengbo Liu; Zonghai Sheng; Huadong Liu; Jie Liu; Xiaojing Gong; Liang Song; Shaohong Dong
Journal:  Theranostics       Date:  2020-03-26       Impact factor: 11.556

Review 7.  Quantitative X-ray phase contrast computed tomography with grating interferometry : Biomedical applications of quantitative X-ray grating-based phase contrast computed tomography.

Authors:  Lorenz Birnbacher; Eva-Maria Braig; Daniela Pfeiffer; Franz Pfeiffer; Julia Herzen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-04-13       Impact factor: 9.236

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.