Textile-based sampling for potentiometric determination of ions.

Grzegorz Lisak1, Thomas Arnebrant2, Tautgirdas Ruzgas2, Johan Bobacka3.   

Abstract

Potentiometric sensing utilizing textile-based micro-volume sampling was applied and evaluated for the determination of clinically (Na(+), K(+), Cl(-)) and environmentally (Cd(2+), Pb(2+) and pH) relevant analytes. In this technological design, calibration solutions and samples were absorbed into textiles while the potentiometric cells (ion-selective electrodes and reference electrode) were pressed against the textile. Once the liquid, by wicking action, reached the place where the potentiometric cell was pressed onto the textile, hence closing the electric circuit, the potentiometric response was obtained. Cotton, polyamide, polyester and their blends with elastane were applied for micro-volume sampling. The textiles were found to influence the determination of pH in environmental samples with pH close to neutral and Pb(2+) at low analyte concentrations. On the other hand, textile-based micro-volume sampling was successfully applied in measurements of Na(+) using solid-contact sodium-selective electrodes utilizing all the investigated textiles for sampling. It was found that in order to extend the application of textile-based sampling toward environmental analysis of ions it will be necessary to tailor the physio-chemical properties of the textile materials. In general, textile-based sampling opens new possibilities for direct chemical analysis of small-volume samples and provide a simple and low-cost method to screen various textiles for their effects on samples to identify which textiles are the most suitable for on-body sensing.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Non-invasive wearable potentiometric sensors; Potentiometric determination of ions in clinical and environmental samples; Textile-based sampling

Mesh:

Substances:

Year:  2015        PMID: 26002212     DOI: 10.1016/j.aca.2015.03.045

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

1.  New bis(azobenzocrown)s with dodecylmethylmalonyl linkers as ionophores for sodium selective potentiometric sensors.

Authors:  Elżbieta Luboch; Maciej Jeszke; Mirosław Szarmach; Natalia Łukasik
Journal:  J Incl Phenom Macrocycl Chem       Date:  2016-09-29       Impact factor: 1.633

Review 2.  A Review of Stimuli-Responsive Smart Materials for Wearable Technology in Healthcare: Retrospective, Perspective, and Prospective.

Authors:  Valentina Trovato; Silvia Sfameni; Giulia Rando; Giuseppe Rosace; Sebania Libertino; Ada Ferri; Maria Rosaria Plutino
Journal:  Molecules       Date:  2022-09-05       Impact factor: 4.927

Review 3.  Skin-interfaced systems for sweat collection and analytics.

Authors:  Jungil Choi; Roozbeh Ghaffari; Lindsay B Baker; John A Rogers
Journal:  Sci Adv       Date:  2018-02-16       Impact factor: 14.136

Review 4.  Recent Advances in Printed Capacitive Sensors.

Authors:  Almudena Rivadeneyra; Juan Antonio López-Villanueva
Journal:  Micromachines (Basel)       Date:  2020-04-01       Impact factor: 2.891

Review 5.  Nanomaterials-patterned flexible electrodes for wearable health monitoring: a review.

Authors:  Md Mehdi Hasan; Md Milon Hossain
Journal:  J Mater Sci       Date:  2021-06-28       Impact factor: 4.220

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.