Literature DB >> 26001259

Dose Reduction in Contrast-Enhanced Cervical MR Angiography: Field Strength Dependency of Vascular Signal Intensity, Contrast Administration, and Arteriographic Quality.

Seena Dehkharghani1, Deqiang Qiu, Lauren S Albin, Amit M Saindane.   

Abstract

OBJECTIVE: Cervical contrast-enhanced MR angiography (MRA) has proven accurate and superior to noncontrast alternatives. We proposed the systematic investigation of dose reduction in contrast-enhanced MRA, hypothesizing heightened tolerance at 3 T vs 1.5 T. Quantitative and qualitative features were compared between full-dose and 50%-reduced dose examinations at 1.5 T and 3 T.
MATERIALS AND METHODS: One hundred eight cervical contrast-enhanced MRA examinations were reviewed for qualitative and quantitative (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]) features across four dose-field strength combinations: 1.5 T, 0.05 mmol/kg; 3 T, 0.05 mmol/kg; 1.5 T, 0.1 mmol/kg; and 3 T, 0.1 mmol/kg. Quantitative features were evaluated among the following segments: aortic arch, common carotid arteries, common carotid bifurcations, and cervical internal carotid arteries. A qualitative visual rating scale was applied for the same segments as well as to the vertebral arteries along their proximal (V1), intraforaminal (V2), and distal extraforaminal (V3) courses. Significant between-group differences were reported at p < 0.05.
RESULTS: Qualitatively good arteriography was observed in all segments for all protocols. No significant qualitative differences between protocols were noted throughout evaluation of the anterior cervical circulation. Significant qualitative differences were observed only for V2 and V3 segments at half-dose 1.5-T compared with the remaining protocols (p < 0.05). No significant quantitative differences were present between full-dose and dose-reduced 3-T MRA in any segment. At 1.5 T, significant decrement in SNR and CNR at half-dose was present only within the cervical internal carotid artery.
CONCLUSION: Dose reduction in cervical contrast-enhanced MRA is feasible at 3 T without significant compromise in arteriographic quality in most segments. Particularly at 3 T, arteriography is quantitatively and qualitatively robust and may be advisable in high-risk patients.

Entities:  

Keywords:  MR angiography (MRA); carotid imaging; dose reduction

Mesh:

Substances:

Year:  2015        PMID: 26001259     DOI: 10.2214/AJR.14.13435

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

1.  Half-dose versus full-dose macrocyclic gadolinium at 3-T magnetic resonance imaging in paediatric bone and soft-tissue disease.

Authors:  Giovanna Stefania Colafati; Enrica Rossi; Chiara Carducci; Simone Piga; Ioan Paul Voicu; Angela Mastronuzzi; Paolo Tomà
Journal:  Pediatr Radiol       Date:  2018-07-25

2.  Dynamic Detection of Thrombolysis in Embolic Stroke Rats by Synchrotron Radiation Angiography.

Authors:  Liping Wang; Panting Zhou; Zhihao Mu; Xiaojie Lin; Lu Jiang; Zhuo Cheng; Longlong Luo; Zhiming Xu; Jieli Geng; Yongting Wang; Zhijun Zhang; Guo-Yuan Yang
Journal:  Transl Stroke Res       Date:  2019-01-24       Impact factor: 6.829

3.  Ferumoxytol-enhanced ultrashort TE MRA and quantitative morphometry of the human kidney vasculature.

Authors:  Liam Timms; Tianyi Zhou; Yue Lyu; Ju Qiao; Vishala Mishra; Rita Maria Lahoud; Gayatri Veeramani Jayaraman; Andrew S Allegretti; David Drew; Ravi T Seethamraju; Mukesh Harisinghani; Srinivas Sridhar
Journal:  Abdom Radiol (NY)       Date:  2021-03-05

4.  Highly time-resolved 4D MR angiography using golden-angle radial sparse parallel (GRASP) MRI.

Authors:  Adam E Goldman-Yassen; Eytan Raz; Maria J Borja; Duan Chen; Anna Derman; Siddhant Dogra; Kai Tobias Block; Seena Dehkharghani
Journal:  Sci Rep       Date:  2022-09-05       Impact factor: 4.996

5.  Simultaneous Imaging of Cerebrovascular Structure and Function in Hypertensive Rats Using Synchrotron Radiation Angiography.

Authors:  Liping Wang; Zhihao Mu; Xiaojie Lin; Jieli Geng; Ti Qiao Xiao; Zhijun Zhang; Yongting Wang; Yongjing Guan; Guo-Yuan Yang
Journal:  Front Aging Neurosci       Date:  2017-11-02       Impact factor: 5.750

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.