Literature DB >> 26001132

Determination of melamine in powdered milk by molecularly imprinted stir bar sorptive extraction coupled with HPLC.

Ling Zhu1, Guanhong Xu1, Fangdi Wei1, Jing Yang1, Qin Hu2.   

Abstract

A novel molecularly imprinted stir bar (MIP-SB) was developed with melamine (MA) as the template molecule in this study. The sorptive capacity of MIP-SB was nearly three times over that of non-imprinted stir bar (NIP-SB). The MIP-SB presented much better selectivity than NIP-SB when used to absorb MA and its analogues. An analytical method to determine MA in powdered milk was established by combining MIP-SB sorptive extraction with HPLC. The liner range was 0.0631-12.6ng/mL with good correlation coefficient of 0.9983, and the limit of detection was 0.0127ng/mL based on three times ratio of signal to noise. This method was successfully applied to the determination of MA in powdered milk with satisfactory results. The method built is simple and suitable for the determination of MA in milk products which is of great significance for quality control of milk products.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Melamine; Milk products; Molecularly imprinted polymer; Stir bar sorptive extraction

Mesh:

Substances:

Year:  2015        PMID: 26001132     DOI: 10.1016/j.jcis.2015.05.008

Source DB:  PubMed          Journal:  J Colloid Interface Sci        ISSN: 0021-9797            Impact factor:   8.128


  4 in total

1.  Visual detection of melamine by using a ratiometric fluorescent probe consisting of a red emitting CdTe core and a green emitting CdTe shell coated with a molecularly imprinted polymer.

Authors:  Liang Zhang; Ligang Chen
Journal:  Mikrochim Acta       Date:  2018-01-26       Impact factor: 5.833

2.  Preparation and characterization of molecularly imprinted solid-phase extraction column coupled with high-performance liquid chromatography for selective determination of melamine.

Authors:  Q Zhou; X C Tan; X J Guo; Y J Huang; H Y Zhai
Journal:  R Soc Open Sci       Date:  2018-09-12       Impact factor: 2.963

Review 3.  Advanced Solid-Phase Microextraction Techniques and Related Automation: A Review of Commercially Available Technologies.

Authors:  Stefano Dugheri; Nicola Mucci; Giovanni Cappelli; Lucia Trevisani; Alessandro Bonari; Elisabetta Bucaletti; Donato Squillaci; Giulio Arcangeli
Journal:  J Anal Methods Chem       Date:  2022-02-04       Impact factor: 2.193

4.  Determination of β-Agonist Residues in Animal-Derived Food by a Liquid Chromatography-Tandem Mass Spectrometric Method Combined with Molecularly Imprinted Stir Bar Sorptive Extraction.

Authors:  Jiwang Tang; Jianxiu Wang; Shuyun Shi; Shengqiang Hu; Liejiang Yuan
Journal:  J Anal Methods Chem       Date:  2018-06-25       Impact factor: 2.193

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.